The phase equilibriums of the ternary system KCl-(NH2)2CO-H2O at 303.15K, 323.15K, 333.15K, and 343.15K were studied using the isothermal dissolution equilibrium method, in which the composition of equilibrium solid phase was determined by Schreinemakers wet residue method and X-ray diffraction (XRD) method. It was found that the ternary system is a simple cosaturated system, without the formation of neither double salt nor solid solution. Wilson and NRTL models were employed to correlate in the solubility data of the system at experimental temperatures. The maximum values of RAD and RMSD of the Wilson model were 2.18×10−2 and 0.83 and those of the NRTL model were 1.69×10−2 and 0.40, respectively. The two models were utilized to forecast solubility data at various temperatures, and the obtained outcomes were in line with the literature data. Based on the experimental solubility data at 343.15K, the cooling crystallization process of the system was monitored online by focused beam reflectance measurement (FBRM) and particle video microscope (PVM). The crystal products were characterized by XRD, scanning electron microscope (SEM), and energy dispersive spectrometry (EDS). The results showed that the precipitation of (NH2)2CO occurred during the crystallization process, and this was followed by KCl. KCl was formed on the surface of (NH2)2CO crystal. The crystal was a simple mixture containing KCl and (NH2)2CO.
Accurate quantification of phosphogypsum (PG) filler in epoxy composites is essential for quality control and performance optimization. Conventional separation by muffle furnace calcination suffers from slow epoxy decomposition and risks thermal degradation of CaSO4, leading to inaccurate PG quantification. This study introduces a microwave-assisted separation method that leverages molecular vibration heating to achieve faster heating rates and more uniform temperature distribution, enabling complete epoxy removal while minimizing CaSO4 decomposition. Comprehensive characterization (X-ray diffraction, XRD; Fourier transform infrared spectroscopy, FT-IR; scanning electron microscopy-energy dispersive spectroscopy, SEM-EDS) confirms the structural integrity of the isolated PG filler. Among five quantification methods evaluated, inductively coupled plasma optical emission spectrometry (ICP-OES) based on sulfur content provides the highest accuracy (spike recovery: 91–99.8%, relative standard deviation, RSD ≤ 4.2%), while gravimetry suffices for single-filler systems. This work establishes a reliable analytical framework for PG characterization in epoxy composites, supporting quality control and resource valorization.
8 May 2024 in Journal of Chemical & Engineering Data