James M. Paci

James M. Paci

Auto-generated profile, based on publicly available information

James M. Paci

Stony Brook University

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2024 in Arthroscopy, Sports Medicine, and Rehabilitation
Verified
Journal Article
Open access
LBLucas Bartlett
Lucas Bartlett
BKBrandon Klein
Brandon Klein
CBChristopher Brancato
Christopher Brancato
SASam Akhavan
Sam Akhavan
JPJames M. Paci
James M. Paci
Purpose: To evaluate the 1‐year clinical outcomes of patients treated with combined proximal biceps tenodesis and repair of type II to III subscapularis tendon (SST) injuries according to Lafosse et al., using the Loop ‘N’ Tack (LNT) technique. Methods: All patients undergoing proximal biceps tenodesis and rotator cuff repair between March 1, 2020, and January 30, 2022, were retrospectively identified. Only patients undergoing combined proximal biceps tenodesis and repair of grade II or III SST injuries with a minimum follow‐up of 1 year were included. All patients underwent combined single‐anchor proximal biceps tenodesis and SST repair using the LNT technique. The following outcome scores were recorded at a final follow‐up of 1 year postoperatively and compared with baseline, preoperative values: American Shoulder and Elbow Score (ASES), Single Assessment Numerical Evaluation (SANE), Veterans Rand 12 Item Health Survey (VR‐12), and visual analog scale (VAS). The minimal clinically important difference (MCID) for all outcome indices was determined with a distribution‐based method. Results: A total of 41 consecutive patients were included. The MCID values for VAS pain, ASES, SANE, and VR‐12 mental scores were 0.97, 8.5, 10.9, and 6.0 respectively. At 1‐year final follow‐up, approximately 95% (39/41) of patients exceeded the MCID for VAS pain scores, 90% (37/41) of patients for ASES scores, 85.4% (34/41) of patients for SANE scores, and 75.6% (31/41) of patients for VR‐12 mental health scores. On average, ASES and SANE scores improved by 37 (preoperatively: 45.2, 1 year: 82.4, P < .001) and 38 points (preoperatively: 38.0, 1 year: 75.7, P < .001), respectively, while VAS scores decreased by 4 points (preoperatively: 5.49, 1 year: 1.48, P < .001). Approximately 88% (36/41) of patients were satisfied at 1 year postoperatively. Treatment failure was observed in 1 patient (2.4%). Conclusions: Patients treated with combined, single‐anchor SST repair and LNT proximal biceps tenodesis achieved significant improvements in function, high satisfaction, and low rates of reoperation at 1 year postoperatively. Additionally, 76% to 95% of patients met the MCID for VAS pain, ASES, SANE, and VR‐12 mental health scores. Level of Evidence: Level IV, retrospective case series.

24 March 2024 in Journal of Orthopaedic Experience & Innovation
Verified
Journal Article
Open access
PDF file
JEJusten Elbayar
Justen Elbayar
DSDavid Swanson
David Swanson
NTNicholas Tsouris
Nicholas Tsouris
DCDorian Cohen
Dorian Cohen
GCGloria Coden
Gloria Coden
JPJames Penna
James Penna
Background: Previous work has demonstrated that with increasing knee flexion angles, the popliteal artery is located further away from the posterior tibial cortex (PTC), thus offering a safer position for procedures about the knee. Prior studies did not, however, incorporate the use of a surgical thigh tourniquet, a device commonly used by orthopaedic surgeons. Thigh tourniquet effect on popliteal spatial anatomy will be assessed in this study. Methods: Using 3 Tesla magnetic resonance imaging, 6 volunteer knees were evaluated in both full extension and 90 degrees (°) of flexion, with and without a thigh tourniquet inflated to 200 millimeters of mercury. Axial images at the level of the posterior cruciate ligament (PCL) tibial insertion were obtained. The distance of the popliteal artery from the PCL tibial insertion and the PTC at this level were calculated. Results: Without a tourniquet, at 0° and 90° of flexion, the mean distance between the popliteal artery and the PTC was 6.9 and 9.4 millimeters, respectively. With a tourniquet, at 0° and 90° the mean distance between the popliteal artery and the PTC decreased to 6.2 (-0.7) and 8 (-1.4) millimeters, respectively. These reductions in distances with inflating the tourniquet were statistically significant (p<0.05). The distance between the artery and the PCL attachment did not change with and without inflating the tourniquet. Conclusions: Inflating a thigh tourniquet moves the popliteal artery approximately 1 millimeter (8.5 percent) anterior towards the PTC and has no effect on the relationship between the popliteal artery and PCL insertion.

2 November 2026 in Orthopaedic Journal of Sports Medicine
Verified
Journal Article
Open access
AAAdam W. Anz
Adam W. Anz
MCMark C. Callanan
Mark C. Callanan
JPJames M. Paci
James M. Paci
MTMarcos D. Tejada
Marcos D. Tejada
BSBenjamin L. Smith
Benjamin L. Smith
Background: Knotless all-suture anchor (ASA) constructs have been proposed for soft tissue onlay fixation in knee ligament procedures. Purpose: To determine the optimal configuration of soft tissue onlay fixation with knotless ASAs that minimizes cyclic elongation and maximizes load-to-failure performance. Study Design: Controlled laboratory study. Methods: Six onlay fixation constructs (n = 7 per group) were biomechanically evaluated in 2 phases using bovine extensor tendons and a polyurethane foam bone replicate. Phase 1 examined 4 knotless ASA configurations using a 2.6-mm double-loaded knotless ASA. The construct with the least cyclic elongation and greatest failure load was advanced to phase 2, where the repair suture limbs were passed back through the tendon tissue and tied for additional fixation. Grafts were incrementally loaded from 10 to 50 N, 10 to 75 N, and 10 to 100 N for 100 cycles, each at 1 Hz, to simulate progressive rehabilitative loading and then loaded to failure at 50 mm/min on a materials testing system. Outcomes included cyclic elongation (millimeters), stiffness (newtons per millimeter), maximum load (newtons) to 5-mm displacement (clinical failure load), maximum load (newtons) to 10-mm displacement (ultimate load), and mode of failure. One-way analysis of variance tests with post hoc Student-Newman-Keuls pairwise comparisons (α = .05) were performed. Results: In phase 1, the knotless rip-stop configuration had the least total cyclic elongation (mean ± SD, 2.21 ± 0.67 mm), greatest ultimate stiffness (130 ± 12 N/mm), greatest clinical failure load (216 ± 35 N), and greatest ultimate load (246 ± 47 N) of knotless constructs. Although the rip-stop showed lower mean cyclic elongation, the performance observed in cyclic loading of the rip-stop configuration was not significantly smaller than 2 of the other 3 techniques. In phase 2, using the repair suture limbs to perform 2 Krackow passes and then tying the limbs together performed the best, further reducing total cyclic elongation to 1.78 ± 0.27 mm ( P = .048), increasing clinical failure load to 269 ± 37 N ( P = .019), and increasing ultimate load to 407 ± 64 N ( P < .001). Conclusion: The rip-stop configuration had the best biomechanical profile of knotless constructs, with equal or less cyclic elongation as well as superior stiffness and failure loads. Passing the repair sutures back through the tissue and tying them together increased the failure load. Clinical Relevance: Knotless onlay fixation has technique-dependent time-zero biomechanical performance, which should be considered intraoperatively.