Ana V. Ferreira

Ana V. Ferreira

Auto-generated profile, based on publicly available information

Ana V. Ferreira

Centre of Biological Engineering (CEB), University of Minho, Campus of Gualtar, 4710-057, Braga, Portugal

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2015 in Macromolecular Materials and Engineering
Verified
Journal Article
Closed access
PDF file
VVVadim Volkov
Vadim Volkov
AFAna V. Ferreira
Ana V. Ferreira
Artur Cavaco-PauloArtur Cavaco-Paulo
Artur Cavaco-Paulo

15 October 2016 in Applied Microbiology and Biotechnology
Verified
Journal Article
Closed access
PDF file
AFAna V. Ferreira
Ana V. Ferreira
IPIlana Perelshtein
Ilana Perelshtein
NPNina Perkas
Nina Perkas
AGAharon Gedanken
Aharon Gedanken
JCJoana Cunha
Joana Cunha
Artur Cavaco-PauloArtur Cavaco-Paulo
Artur Cavaco-Paulo

29 January 2015 in Engineering in Life Sciences
Verified
Journal Article
Closed access
AFAna V. Ferreira
Ana V. Ferreira
VVVadim Volkov
Vadim Volkov
AAAna S. Abreu
Ana S. Abreu
NANuno Azoia
Nuno Azoia
Claudia BotelhoClaudia Botelho
Claudia Botelho
Artur Cavaco-PauloArtur Cavaco-Paulo
Artur Cavaco-Paulo

1 June 2019 in Biotechnology Reports
Verified
Journal Article
Open access
AFAna V. Ferreira
Ana V. Ferreira
EAEgipto Antunes
Egipto Antunes
Artur RibeiroArtur Ribeiro
Artur Ribeiro
Teresa MatamáTeresa Matamá
Teresa Matamá
NANuno G. Azoia
Nuno G. Azoia
Artur Cavaco-PauloArtur Cavaco-Paulo
Artur Cavaco-Paulo
Recent studies have demonstrated that human neutrophil elastase (HNE) can be used as marker for inflammation/infection of chronic wounds since it was found to be present in high concentration in exudate collected from chronic wounds. Biosensors used in wound care benefit from a chromogenic signalling due to the readiness of signal interpretation, but the most common use faint yellow chromogenic molecules such as p-nitroaniline (pNa). In addition, if to be converted into smart dressings, the colour of the detection system should not be masked by the exudate's colour. In this work, we designed a chromogenic substrate for HNE aiming to be incorporated in a smart dressing as a colour switch sensor. The substrate was developed using the GFP-like chromoprotein ultramarine (UM), following the split GFP technology. The cleavage sequence for HNE (Ala-Ala-Pro-Val) was embedded into the sensing moiety of the substrate corresponding to the 11th β-sheet. In the presence of HNE, the 11th β-sheet is able to interact to the signalling moiety composed of the β1-β10 incomplete barrel, allowing the re-establishment of the chromophore environment and, hence, the colour production. Structural homology and molecular dynamics simulations were conducted to aid on the disclosure of the structural changes that are the base of the mechanism of action of this HNE switch substrate. Our findings explore the possible application of GFP-like chromogenic sensors in point-of-care devices for the evaluation of the wounds status, representing a major step in the medical field.