Jinglan Li

Jinglan Li

Auto-generated profile, based on publicly available information

Jinglan Li

Medical School of Chinese PLA, Beijing, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Experimental Eye Research
Verified
Journal Article
Closed access
TMTianju Ma
Tianju Ma
DLDi-Hui Lan
Di-Hui Lan
SHShou-Zhi He
Shou-Zhi He
ZYZi Ye
Zi Ye
PLPeng Li
Peng Li
ZLZhaohui Li
Zhaohui Li

30 April 2020 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
YGYi Gao
Yi Gao
ZYZi Ye
Zi Ye
WCWenqian Chen
Wenqian Chen
JLJinglan Li
Jinglan Li
XYXinlin Yan
Xinlin Yan
ZLZhaohui Li
Zhaohui Li
Purpose. To evaluate visual acuity (VA) and refractive status in patients with cataract and irregular astigmatism with a regular central component after phacoemulsification with implantation of a toric intraocular lens (IOL). Methods. Patients with cataract associated with irregular astigmatism with a regular central component were enrolled. All patients underwent phacoemulsification and toric IOL implantation. Postoperative visual acuity, residual astigmatism, toric IOL rotation, higher-order aberration, and objective and subjective visual quality were measured 3 months after surgery. Results. Twenty-three eyes were included in the study. The logMAR corrected and uncorrected distance visual acuity values were decreased at 3 months postoperatively (p < 0.005). The preoperative average corneal astigmatism and postoperative residual astigmatism were 1.15–6.97 D (1.99 ± 1.26 D) and 0–2.75 D (0.65 ± 0.57 D), respectively. The average IOL rotation was 3.17 ± 2.01°. Some objective indicators of visual quality, including the modulation transfer function (p < 0.05), Strehl ratio (p < 0.005), 100% VA (p < 0.005), 20% VA (p < 0.005), and 9% VA (p < 0.005), were significantly higher than the corresponding preoperative values. The objective scatter index (p < 0.005) was significantly lower than that before surgery. The postoperative VF-14 scale score was 83.99 ± 14.58. Conclusion. Toric IOL implantation has a good corrective effect on certain specific types of corneal irregular astigmatism with cataract. This effect can be attributed to its ability to correct the regular component of irregular astigmatism. The indications for toric IOL implantation could be expanded to some extent, thereby bringing benefit to more patients.

13 July 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
HGHui-Zhi Guo
Hui-Zhi Guo
SZShun-Cong Zhang
Shun-Cong Zhang
DGDan-Qing Guo
Dan-Qing Guo
YMYan-Huai Ma
Yan-Huai Ma
KYKai Yuan
Kai Yuan
YTYong-Chao Tang
Yong-Chao Tang
Background: Polymethylmethacrylate (PMMA) is commonly used for cement-augmented pedicle screw instrumentation (CAPSI) to improve the fixation stability and reduce the risk of screw loosening in the osteoporotic thoracolumbar spine. Biomechanical researches have shown that various dose of cement (1-3 ml) can be injected to enhance screw stability. To date, there have been no studies on the relationship between adjacent segment degeneration and the volume of PMMA. This study aimed to explore the influence of CAPSI with different volumes of PMMA in osteoporotic lumbar vertebrae over adjacent segments by using finite element analysis. Methods: Seven different finite element models were reconstructed and simulated under different loading conditions, including (1) an intact model, (2) three single-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml), and (3) three double-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml). To improve the accuracy of the finite element analysis, the models of the injectable pedicle screw and bone cement were created by using a three-dimensional scanning machine and the CAPSI patient’s CT data, respectively. The range of motion (ROM), the stress of intervertebral discs, and the stress of facet in the adjacent segment were comparatively analyzed among the different models. Results: The ROMs of the different segments were compared with experimental data, with good agreement under the different load conditions (21.3°, 13.55°, 13.99°, and 6.11° in flexion, extension, bending, and rotation at L3-S1 level, respectively). Compared with the intact model, the ROM, disc stresses, and facet stress in adjacent segments were found to be higher in the six operative models. Otherwise, with a larger volume of PMMA injected, the ROM, disc stresses, and facet stress slightly increased at the adjacent segment. However, the differences were insignificant with the biggest difference less than 3.8%. Conclusions: CAPSI could increase the incidence of disk degeneration in the adjacent segment, while within a certain range, different volumes of PMMA provided an approximate impact over the adjacent segment degeneration.

1 August 2024 in Journal of Food Measurement and Characterization
Verified
Journal Article
Closed access
PDF file
JSJianrui Sun
Jianrui Sun
RRRuirui Ren
Ruirui Ren
LYLinlin Yao
Linlin Yao
LTLi Tong
Li Tong
JLJinglan Li
Jinglan Li
GSGu Shaobin
Gu Shaobin

3 May 2023 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
XLXuanlong Li
Xuanlong Li
JLJinglan Li
Jinglan Li
DSDi Sun
Di Sun
TMTianju Ma
Tianju Ma
WCWenqian Chen
Wenqian Chen
ZLZhaohui Li
Zhaohui Li
Introduction Posterior capsular opacification (PCO) is the most common complication of cataract surgery. In this study, we develop a model to quantitatively predict the probability of Nd:YAG laser capsulotomy for vision-threatening PCO to improve the life quality of postoperative patients. Methods A registry analysis of cataract procedures performed between the years 2010 and 2021. Following the screening of 16,802 patients (25,883 eyes), 9768 patients (eyes) were enrolled. The cohort was randomly divided into two groups: training (n = 6838) and validation (n = 2930). To identify relevant risk factors, univariate, multivariate, and Least Absolute Shrinkage and Selection Operator (LASSO) algorithm Cox regression analysis were employed, and a nomogram was created to demonstrate the prediction result. Results At 5 years, the overall cumulative incidence of Nd:YAG laser capsulotomy was 12.0% (1169/9768). The following variables were included in the prediction model: sex [hazard ratio (HR) = 1.53, 95% CI 1.32–1.76], age (HR = 0.71, 95% CI 0.56–0.88), intraocular lens (IOL) material (HR = 2.65, 95% CI 2.17–3.24), high myopia (HR = 2.28, 95% CI 1.90–2.75), and fibrinogen (HR = 0.79, 95% CI 0.72–0.88). In the validation cohort, the area under the curve (AUC) of 1-, 3-, and 5-year predictions for Nd:YAG laser capsulotomy were 0.702, 0.691, and 0.688, respectively. For a subgroup of patients with high myopia, the protective effect of hydrophobic IOL disappeared (HR = 0.68, 95% CI 0.51–1.12, P = 0.127). Conclusion This model could predict the probability of Nd:YAG laser capsulotomy for vision-threatening PCO after cataract surgery by taking into account factors such as age, gender, IOL material, high myopia, and fibrinogen. Meanwhile, implantation of a hydrophobic IOL in individuals with high myopia did not demonstrate a protective impact against vision-threatening PCO.

26 August 2022 in Diabetology & Metabolic Syndrome
Verified
Journal Article
Open access
PDF file
JLJinglan Li
Jinglan Li
XLXuanlong Li
Xuanlong Li
MLMingxing Lei
Mingxing Lei
WLWanyue Li
Wanyue Li
WCWenqian Chen
Wenqian Chen
ZLZhaohui Li
Zhaohui Li
Background: As one of the severe complications of diabetes mellitus, diabetic retinopathy (DR) is the leading cause of blindness in the working age worldwide. Although panretinal photocoagulation (PRP) was standard treatment, PRP-treated DR still has a high risk of progression. Hence, this study aimed to assess the risk factors and establish a model for predicting worsening diabetic retinopathy (DR-worsening) within five years after PRP. Methods: Patients who were diagnosed with severe non-proliferative diabetic retinopathy or proliferative diabetic retinopathy and treated with PRP were included, and those patients were randomly assigned to either a training or validation cohort. The multivariate logistic regression analysis was used to screen potential risk factors for DR-worsening in the training cohort. Then the model was established after including significant independent risk factors and further validated using discrimination and calibration. Results: A total of 271 patients were included, and 56.46% of patients had an outcome of DR-worsening. In the training cohort (n = 135), age (odds ratio [OR] = 0.94, 95% confidence interval [CI] 0.90–0.98), baseline best corrected visual acuity (logMAR) (OR = 10.74, 95% CI 1.84–62.52), diabetic nephropathy (OR = 9.32, 95% CI 1.49–58.46), and hyperlipidemia (OR = 3.34, 95% CI 1.05–10.66) were screened out as the independent risk factors, which were incorporated into the predictive model. The area under the receiver operating characteristic curve and calibration slope in the training and validation cohort were 0.79, 0.96 (95% CI 0.60–1.31), and 0.79, 1.00 (95% CI 0.66–1.34), respectively. Two risk groups were developed depending on the best cut-off value of the predicted probability, and the actual probability was 34.90% and 82.79% in the low-risk and high-risk groups, respectively (P < 0.001). Conclusions: This study developed and internally validated a new model to predict the probability of DR-worsening after PRP treatment within five years. The model can be used as a rapid risk assessment system for clinical prediction of DR-worsening and identify individuals at a high risk of DR-worsening at an early stage and prescribe additional treatment.