Thorsten Perl

Thorsten Perl

Auto-generated profile, based on publicly available information

Thorsten Perl

University of Göttingen

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2012 in Applied Microbiology and Biotechnology
Verified
Journal Article
Open access
PDF file
MJMelanie Jünger
Melanie Jünger
WVWolfgang Vautz
Wolfgang Vautz
MKMartin Kuhns
Martin Kuhns
LHLena Hofmann
Lena Hofmann
SUSiobhán Ulbricht
Siobhán Ulbricht
TPThorsten Perl
Thorsten Perl
Presently, 2 to 4 days elapse between sampling at infection suspicion and result of microbial diagnostics. This delay for the identification of pathogens causes quite often a late and/or inappropriate initiation of therapy for patients suffering from infections. Bad outcome and high hospitalization costs are the consequences of these currently existing limited pathogen identification possibilities. For this reason, we aimed to apply the innovative method multi-capillary column–ion mobility spectrometry (MCC-IMS) for a fast identification of human pathogenic bacteria by determination of their characteristic volatile metabolomes. We determined volatile organic compound (VOC) patterns in headspace of 15 human pathogenic bacteria, which were grown for 24 h on Columbia blood agar plates. Besides MCC-IMS determination, we also used thermal desorption–gas chromatography–mass spectrometry measurements to confirm and evaluate obtained MCC-IMS data and if possible to assign volatile compounds to unknown MCC-IMS signals. Up to 21 specific signals have been determined by MCC-IMS for Proteus mirabilis possessing the most VOCs of all investigated strains. Of particular importance is the result that all investigated strains showed different VOC patterns by MCC-IMS using positive and negative ion mode for every single strain. Thus, the discrimination of investigated bacteria is possible by detection of their volatile organic compounds in the chosen experimental setup with the fast and cost-effective method MCC-IMS. In a hospital routine, this method could enable the identification of pathogens already after 24 h with the consequence that a specific therapy could be initiated significantly earlier.

3 November 2009 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PDF file
TPT. Perl
T. Perl
ECE. Carstens
E. Carstens
AHA. Hirn
A. Hirn
MQM. Quintel
M. Quintel
WVW. Vautz
W. Vautz
MJM. Jünger
M. Jünger
We aimed to measure propofol concentrations in exhaled air with an ion mobility spectrometer coupled to a multicapillary column for pre-separation (MCC–IMS). In addition, we aimed to compare the values of these measurements with serum propofol concentrations, as determined by gas chromatography–mass spectrometry (GC–MS). Thirteen patients, ASA I or II, undergoing elective ENT surgery were studied. Anaesthesia was induced with propofol 2.1 (0.7) mg kg−1, rocuronium 0.5 (0.1) mg kg−1, and remifentanil 0.5 µg kg−1 min−1. After tracheal intubation, anaesthesia was maintained with a continuous infusion of propofol 3.9 (1.8) mg kg−1 h−1 and remifentanil 0.5 µg kg−1 min−1. Simultaneously, a venous blood sample was obtained. Propofol concentrations in serum were determined by GC–MS and compared with the height of the respective propofol signals achieved by MCC–IMS. Twenty-four pairs of samples were obtained. The comparison of propofol concentrations in exhaled air and serum presented a bias of −10.5% and a precision of ± 12.3%. With these values, the 95% limits of agreement were 14.1% and −35.1%. MCC–IMS may be a suitable method to determine propofol concentrations in exhaled air, and may be used to predict propofol concentrations in serum.

12 June 2011 in Mycoses
Verified
Journal Article
Closed access
PDF file
TPThorsten Perl
Thorsten Perl
MJMelanie Jünger
Melanie Jünger
WVWolfgang Vautz
Wolfgang Vautz
JNJürgen Nolte
Jürgen Nolte
MKMartin Kuhns
Martin Kuhns
MQMichael Quintel
Michael Quintel

30 October 2019 in Applied Microbiology and Biotechnology
Verified
Journal Article
Closed access
PDF file
CDCarolin Drees
Carolin Drees
WVWolfgang Vautz
Wolfgang Vautz
SLSascha Liedtke
Sascha Liedtke
CRChristopher Rosin
Christopher Rosin
KAKirsten Althoff
Kirsten Althoff
NKNils Kunze-Szikszay
Nils Kunze-Szikszay

7 March 2013 in Applied Microbiology and Biotechnology
Verified
Journal Article
Open access
PDF file
NKNils Kunze-Szikszay
Nils Kunze-Szikszay
JGJulia Göpel
Julia Göpel
MKMartin Kuhns
Martin Kuhns
MJMelanie Jünger
Melanie Jünger
MQMichael Quintel
Michael Quintel
TPThorsten Perl
Thorsten Perl
Headspace analyses over microbial cultures using multi-capillary column-ion mobility spectrometry (MCC-IMS) could lead to a faster, safe and cost-effective method for the identification of pathogens. Recent studies have shown that MCC-IMS allows identification of bacteria and fungi, but no information is available from when on during their growth a differentiation between bacteria is possible. Therefore, we analysed the headspace over human pathogenic reference strains of Escherichia coli and Pseudomonas aeruginosa at four time points during their growth in a complex fluid medium. In order to validate our findings and to answer the question if the results of one bacterial strain can be transferred to other strains of the same species, we also analysed the headspace over cultures from isolates of random clinical origin. We detected 19 different volatile organic compounds (VOCs) that appeared or changed their signal intensity during bacterial growth. These included six VOCs exclusively changing over E. coli cultures and seven exclusively changing over P. aeruginosa cultures. Most changes occurred in the late logarithmic or static growth phases. We did not find differences in timing or trends in signal intensity between VOC patterns of different strains of one species. Our results show that differentiation of human pathogenic bacteria by headspace analyses using MCC-IMS technology is best possible during the late phases of bacterial growth. Our findings also show that VOC patterns of a bacterial strain can be transferred to other strains of the same species.

30 May 2010 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
TPThorsten Perl
Thorsten Perl
BBBertram Bödeker
Bertram Bödeker
MJMelanie Jünger
Melanie Jünger
JNJürgen Nolte
Jürgen Nolte
WVWolfgang Vautz
Wolfgang Vautz
Multicapillary column (MCC) ion mobility spectrometers (IMS) are increasingly in demand for medical diagnosis, biological applications and process control. In a MCC-IMS, volatile compounds are differentiated by specific retention time and ion mobility when rapid preseparation techniques are applied, e.g. for the analysis of complex and humid samples. Therefore, high accuracy in the determination of both parameters is required for reliable identification of the signals. The retention time in the MCC is the subject of the present investigation because, for such columns, small deviations in temperature and flow velocity may cause significant changes in retention time. Therefore, a universal correction procedure would be a helpful tool to increase the accuracy of the data obtained from a gas-chromatographic preseparation. Although the effect of the carrier gas flow velocity and temperature on retention time is not linear, it could be demonstrated that a linear alignment can compensate for the changes in retention time due to common minor deviations of both the carrier gas flow velocity and the column temperature around the MCC-IMS standard operation conditions. Therefore, an effective linear alignment procedure for the correction of those deviations has been developed from the analyses of defined gas mixtures under various experimental conditions. This procedure was then applied to data sets generated from real breath analyses obtained in clinical studies using different instruments at different measuring sites for validation. The variation in the retention time of known signals, especially for compounds with higher retention times, was significantly improved. The alignment of the retention time—an indispensable procedure to achieve a more precise identification of analytes—using the proposed method reduces the random error caused by small accidental deviations in column temperature and flow velocity significantly.