This paper reports the first in-vivo testing of a resonant-heating stent towards wireless hyperthermia treatment of in-stent restenosis. The stent, made of gold-coated medical-grade stainless steel, is designed to function as an electrical inductor and form a radiofrequency (RF) resonant circuit with an integrated capacitor microchip. Upon implantation and deployment with the balloon catheter, the stent device serves as a wireless heater as part of the resonant wireless power transfer system, which allows for the device to produce mild heat only when the stent is resonated with a tuned RF electromagnetic field supplied from the external antenna. The wireless power transmitter includes an independent omnidirectional booster antennas that enhances the power delivery to the implanted stent device. The entire stent device is packaged with 40-μm-thick Parylene C film that is shown to be essential for minimizing electrothermal damping in a conductive liquid like blood. The in-vitro tests of the prototype system show a temperature increase of 3.3 °C in the stent device coupled in a flow loop of saline at a flow rate relevant to the condition of coronary stenosis. In swine models, the system demonstrates RF heating of the stent devices expanded to different diameters, in live blood stream, achieving temperature rises of up to 2.6 °C in a consistent and repeatable manner. These results bring the technology one step closer towards clinical realization of wireless thermal therapy of in-stent restenosis.
4 October 2019 in IEEE Transactions on Antennas and Propagation
This paper presents an electromagnetically powered stent designed for hyperthermia treatment of in-stent restenosis. The stent device based on medical-grade stainless steel serves as a radiofrequency inductive receiver to produce mild heating wirelessly through resonant-coupling power transfer, while acting as a mechanical scaffold inside an artery similar to commercial stents. The device and its custom transmitter are prototyped and optimized to show efficient wireless power transfer and stent heating through in-vitro tests. The inductive stent with its helical pattern is gold coated to achieve a 3.5× higher quality (Q) factor, improving heating performance of the device. The combinational use of independent resonant antennas with the power antenna is found to significantly boost stent temperature by up to 96% with intermediate tissue layer. Upon matching the frequencies at which the Q factors of the inductive stent, power antenna, and booster antenna are peaked, the stent excited through 10-mm-thick tissue exhibits a temperature increase of 18 °C, well over a necessary level for targeted hyperthermia treatment. The prototype achieves heating efficiencies of 15.5-3.2 °C/W with tissue thickness of 5-15 mm. These results indicate that the proposed resonant-heating stent system with the prototyped transmitter is promising for further development towards its clinical application.