Mattia Busana

Mattia Busana

Auto-generated profile, based on publicly available information

Mattia Busana

Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2020 in Intensive Care Medicine
Verified
Journal Article
Open access
PDF file
LGLuciano Gattinoni
Luciano Gattinoni
DCDavide Chiumello
Davide Chiumello
PCPietro Caironi
Pietro Caironi
MBMattia Busana
Mattia Busana
FRFederica Romitti
Federica Romitti
LCLuigi Camporota
Luigi Camporota

15 May 2020 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Open access
LGLuciano Gattinoni
Luciano Gattinoni
Silvia CoppolaSilvia Coppola
Silvia Coppola
MCMassimo Cressoni
Massimo Cressoni
MBMattia Busana
Mattia Busana
SRSandra Rossi
Sandra Rossi
Davide ChiumelloDavide Chiumello
Davide Chiumello

27 November 2019 in Intensive Care Medicine Experimental
Verified
Journal Article
Open access
PDF file
LGLorenzo Giosa
Lorenzo Giosa
MBMattia Busana
Mattia Busana
IPIacopo Pasticci
Iacopo Pasticci
MBMatteo Bonifazi
Matteo Bonifazi
MMMatteo Maria Macrì
Matteo Maria Macrì
LGLuciano Gattinoni
Luciano Gattinoni
Background: Mechanical power is a summary variable including all the components which can possibly cause VILI (pressures, volume, flow, respiratory rate). Since the complexity of its mathematical computation is one of the major factors that delay its clinical use, we propose here a simple and easy to remember equation to estimate mechanical power under volume-controlled ventilation: $$ \mathrm{Mechanical}\ \mathrm{Power}=\frac{\mathrm{VE}\times \left(\mathrm{Peak}\ \mathrm{Pressure}+\mathrm{PEEP}+F/6\right)}{20} $$Mechanical Power=VE×Peak Pressure+PEEP+F/620 where the mechanical power is expressed in Joules/minute, the minute ventilation (VE) in liters/minute, the inspiratory flow (F) in liters/minute, and peak pressure and positive end-expiratory pressure (PEEP) in centimeter of water. All the components of this equation are continuously displayed by any ventilator under volume-controlled ventilation without the need for clinician intervention.To test the accuracy of this new equation, we compared it with the reference formula of mechanical power that we proposed for volume-controlled ventilation in the past. The comparisons were made in a cohort of mechanically ventilated pigs (485 observations) and in a cohort of ICU patients (265 observations).Results: Both in pigs and in ICU patients, the correlation between our equation and the reference one was close to the identity. Indeed, theR2ranged from 0.97 to 0.99 and the Bland-Altman showed small biases (ranging from + 0.35 to − 0.53 J/min) and proportional errors (ranging from + 0.02 to − 0.05).Conclusions: Our new equation of mechanical power for volume-controlled ventilation represents a simple and accurate alternative to the more complex ones available to date. This equation does not need any clinical intervention on the ventilator (such as an inspiratory hold) and could be easily implemented in the software of any ventilator in volume-controlled mode. This would allow the clinician to have an estimation of mechanical power at a simple glance and thus increase the clinical consciousness of this variable which is still far from being used at the bedside. Our equation carries the same limitations of all other formulas of mechanical power, the most important of which, as far as it concerns VILI prevention, are the lack of normalization and its application to the whole respiratory system (including the chest wall) and not only to the lung parenchyma.

20 October 2021 in European Respiratory Review
Verified
Journal Article
Open access
PDF file
LGLuciano Gattinoni
Luciano Gattinoni
SGSimone Gattarello
Simone Gattarello
ISIrene Steinberg
Irene Steinberg
MBMattia Busana
Mattia Busana
PPPaola Palermo
Paola Palermo
LCLuigi Camporota
Luigi Camporota
Coronavirus disease 2019 (COVID-19) pneumonia is an evolving disease. We will focus on the development of its pathophysiologic characteristics over time, and how these time-related changes determine modifications in treatment. In the emergency department: the peculiar characteristic is the coexistence, in a significant fraction of patients, of severe hypoxaemia, near-normal lung computed tomography imaging, lung gas volume and respiratory mechanics. Despite high respiratory drive, dyspnoea and respiratory rate are often normal. The underlying mechanism is primarily altered lung perfusion. The anatomical prerequisites for PEEP (positive end-expiratory pressure) to work (lung oedema, atelectasis, and therefore recruitability) are lacking. In the high-dependency unit: the disease starts to worsen either because of its natural evolution or additional patient self-inflicted lung injury (P-SILI). Oedema and atelectasis may develop, increasing recruitability. Noninvasive supports are indicated if they result in a reversal of hypoxaemia and a decreased inspiratory effort. Otherwise, mechanical ventilation should be considered to avert P-SILI. In the intensive care unit: the primary characteristic of the advance of unresolved COVID-19 disease is a progressive shift from oedema or atelectasis to less reversible structural lung alterations to lung fibrosis. These later characteristics are associated with notable impairment of respiratory mechanics, increased arterial carbon dioxide tension (PaCO2), decreased recruitability and lack of response to PEEP and prone positioning.

1 February 2019 in Seminars in Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
PDF file
LGLuciano Gattinoni
Luciano Gattinoni
MBMattia Busana
Mattia Busana
LGLorenzo Giosa
Lorenzo Giosa
MMMatteo Maria Macrì
Matteo Maria Macrì
MQMichael Quintel
Michael Quintel
Prone positioning is nowadays considered as one of the most effective strategies for patients with severe acute respiratory distress syndrome (ARDS). The evolution of the pathophysiological understanding surrounding the prone position closely follows the history of ARDS. At the beginning, the focus of the prone position was the improvement in oxygenation attributed to a perfusion redistribution. However, the mechanisms behind the prone position are more complex. Indeed, the positive effects on oxygenation and CO2 clearance of the prone position are to be ascribed to a more homogeneous inflation–ventilation, to the lung/thoracic shape mismatch, and to the change of chest wall elastance. In the past 20 years, five major trials have tried, starting from different theories, hypotheses, and designs, to demonstrate the effectiveness of the prone position, which finally found its definitive place among the different ARDS supportive therapies.

1 May 2020 in Anesthesiology
Verified
Journal Article
Closed access
FVFrancesco Vassalli
Francesco Vassalli
IPIacopo Pasticci
Iacopo Pasticci
FRFederica Romitti
Federica Romitti
EDEleonora Duscio
Eleonora Duscio
DADavid Jerome Aßmann
David Jerome Aßmann
LGLuciano Gattinoni
Luciano Gattinoni
Background: Excessive tidal volume, respiratory rate, and positive end-expiratory pressure (PEEP) are all potential causes of ventilator-induced lung injury, and all contribute to a single variable: the mechanical power. The authors aimed to determine whether high tidal volume or high respiratory rate or high PEEP at iso-mechanical power produce similar or different ventilator-induced lung injury. Methods: Three ventilatory strategies—high tidal volume (twice baseline functional residual capacity), high respiratory rate (40 bpm), and high PEEP (25 cm H2O)—were each applied at two levels of mechanical power (15 and 30 J/min) for 48 h in six groups of seven healthy female piglets (weight: 24.2 ± 2.0 kg, mean ± SD). Results: At iso-mechanical power, the high tidal volume groups immediately and sharply increased plateau, driving pressure, stress, and strain, which all further deteriorated with time. In high respiratory rate groups, they changed minimally at the beginning, but steadily increased during the 48 h. In contrast, after a sudden huge increase, they decreased with time in the high PEEP groups. End-experiment specific lung elastance was 6.5 ± 1.7 cm H2O in high tidal volume groups, 10.1 ± 3.9 cm H2O in high respiratory rate groups, and 4.5 ± 0.9 cm H2O in high PEEP groups. Functional residual capacity decreased and extravascular lung water increased similarly in these three categories. Lung weight, wet-to-dry ratio, and histologic scores were similar, regardless of ventilatory strategies and power levels. However, the alveolar edema score was higher in the low power groups. High PEEP had the greatest impact on hemodynamics, leading to increased need for fluids. Adverse events (early mortality and pneumothorax) also occurred more frequently in the high PEEP groups. Conclusions: Different ventilatory strategies, delivered at iso-power, led to similar anatomical lung injury. The different systemic consequences of high PEEP underline that ventilator-induced lung injury must be evaluated in the context of the whole body. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New: