Tong Huang

Tong Huang

Auto-generated profile, based on publicly available information

Tong Huang

Electrical and Computer Engineering Department, Texas A&M University College Station, 14736 College Station, Texas United States 77843

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
THTong Huang
Tong Huang
BSBharadwaj Satchidanandan
Bharadwaj Satchidanandan
PKP. R. Kumar
P. R. Kumar
LXLe Xie
Le Xie
We propose an online framework to detect cyber attacks on Automatic Generation Control (AGC). A cyber attack detection algorithm is designed based on the approach of Dynamic Watermarking. The detection algorithm provides a theoretical guarantee of detection of cyber attacks launched by sophisticated attackers possessing extensive knowledge of the physical and statistical models of targeted power systems. The proposed framework is practically implementable, as it needs no hardware update on generation units. The efficacy of the proposed framework is validated in both four-area system and 140-bus system.

5 October 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
THTong Huang
Tong Huang
SGSicun Gao
Sicun Gao
LXLe Xie
Le Xie
This paper proposes a novel Neural Lyapunov method-based transient stability assessment framework for power electronics-interfaced networked microgrids. The assessment framework aims to determine the large-signal stability of the networked microgrids and to characterize the disturbances that can be tolerated by the networked microgrids. The challenge of such assessment is how to construct a behavior-summary function for the nonlinear networked microgrids. By leveraging strong representation power of neural network, the behavior-summary function, i.e., a Neural Lyapunov function, is learned in the state space. A stability region is estimated based on the learned Neural Lyapunov function, and it is used for characterizing disturbances that the networked microgrids can tolerate. The proposed method is tested and validated in a grid-connected microgrid, three networked microgrids with mixed interface dynamics, and the IEEE 123-node feeder. Case studies suggest that the proposed method can address networked microgrids with heterogeneous interface dynamics, and in comparison with conventional methods that are based on quadratic Lyapunov functions, it can characterize the stability regions with much less conservativeness.

20 March 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
THTong Huang
Tong Huang
NFNikolaos M. Freris
Nikolaos M. Freris
PKP. R. Kumar
P. R. Kumar
LXLe Xie
Le Xie
This paper proposes a data-driven algorithm for locating the source of forced oscillations and suggests a physical interpretation for the method. By leveraging the sparsity of forced oscillations along with the low-rank nature of synchrophasor data, the problem of source localization under resonance conditions is cast as computing the sparse and low-rank components using Robust Principal Component Analysis (RPCA), which can be efficiently solved by the exact Augmented Lagrange Multiplier method. Based on this problem formulation, an efficient and practically implementable algorithm is proposed to pinpoint the forced oscillation source during real-time operation. Furthermore, theoretical insights are provided for the efficacy of the proposed approach, by use of physical model-based analysis, specifically by highlighting the low-rank nature of the resonance component matrix. Without the availability of system topology information, the proposed method can achieve high localization accuracy in synthetic cases based on benchmark systems and real-world forced oscillations in the power grid of Texas.

3 May 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
THTong Huang
Tong Huang
DWDan Wu
Dan Wu
MIMarija Ilic
Marija Ilic
In this paper we propose a co-design of the secondary frequency regulation in systems of AC microgrids and its cyber security solutions. We term the secondary frequency regulator a Micro-Automatic Generation Control $(\mu $ AGC) for highlighting its same functionality as the AGC in bulk power systems. We identify sensory challenges and cyber threats facing the $\mu $ AGC. To address the sensory challenges, we introduce a new microgrid model by exploiting the rank-one deficiency property of microgrid dynamics. This model is used to pose an optimal $\mu $ AGC control problem that is easily implemented, because it does not require fast frequency measurements. An end-to-end cyber security solution to the False Data Injection (FDI) attack detection and mitigation is developed for the proposed $\mu $ AGC. The front-end barrier of applying off-the-shelf algorithms for cyber attack detection is removed by introducing a data-driven modeling approach. Finally, we propose an observer-based corrective control for an islanded microgrid and a collaborative mitigation scheme in systems of AC microgrids. We demonstrate a collaborative role of systems of microgrids during cyber attacks. The performance of the proposed cyber-resilient $\mu $ AGC is tested in a system of two networked microgrids.

6 September 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
WKWoo-Hyun Ko
Woo-Hyun Ko
JRJorge A. Ramos-Ruiz
Jorge A. Ramos-Ruiz
THTong Huang
Tong Huang
JKJaewon Kim
Jaewon Kim
HIHasan Ibrahim
Hasan Ibrahim
LXLe Xie
Le Xie
Grid-connected inverter systems that are important for increased utilization of renewable energy are vulnerable to cyberattacks. Malicious agents can attack a system by providing false measurements of sensed signals, such as power available/generated, or the grid current to sabotage the inverter control system. To defend against such attacks, we propose a technique of dynamic watermarking that superimposes a small secret signal onto the actuator signal and raises an alarm when the purported measurement data returned from the sensors do not contain appropriate transformations of the secret watermark. In this article, a robust attack detector is introduced, which does not require either knowledge of the variance of the ambient sensor noise or a model of the system. We develop an additional test that is not only impervious to sensor noise variance but can also be used to distinguish malicious attacks from sensor unreliability due to changing levels of sensor noise. We also show that a data-driven system identification of the switching inverter system can be employed in the dynamic watermarking tests. We present both simulation and experimental results from a grid-connected photovoltaic (PV) system, which show that the resulting robust dynamic watermarking method can detect malicious attacks on inverter control systems.

21 August 2024 in Nature Climate Change
Verified
Journal Article
Closed access
PDF file
LXLe Xie
Le Xie
SMSubir Majumder
Subir Majumder
THTong Huang
Tong Huang
QZQian Zhang
Qian Zhang
PCPing Chang
Ping Chang
MSMohammad Shahidehpour
Mohammad Shahidehpour