31 May 2019 in IEEE Antennas and Wireless Propagation Letters
A compact dual-band and dual-circular polarization (CP) stacked patch antenna is investigated for BeiDou navigation satellite system (BDS). The proposed antenna employs a single coaxial probe to feed two layers of patches simultaneously, realizing dual-band operation. The bottom patch with symmetrical slant corner-cuts and the top one with two rectangular stubs on the diagonal produce a pair of degenerated modes, achieving CP radiation. Furthermore, two L-shaped stubs are loaded on the top patch to widen impedance bandwidth. A prototype operating at the bands of 1.615/2.492 GHz was fabricated and measured. Both the left- and right-handed CP radiations are obtained concurrently in the dual bands. The proposed antenna has a profile of 4.6 mm (0.024 $\lambda_0$ ) and occupies an area of 70 mm × 70 mm (0.38 $\lambda_0$ × 0.38 $\lambda_0$ ). The measured impedance bandwidth with | $S_11$ | < -10 dB is 9.1% and 5.1% for the lower and upper bands, respectively. The measured 3-dB axial ratio (AR) bandwidth is more than 1% for both bands.
26 July 2021 in IEEE Transactions on Antennas and Propagation
A broadband circularly polarized (BCP) all-textile antenna and its wearable conformal antenna array (WCAA) are investigated for body-centric communications. Initially, a circularly polarized (CP) microstrip patch antenna loaded with a piece of the modified metasurface is designed to achieve wide impedance and axial ratio (AR) bandwidths. The characteristic mode analysis is employed to understand the operating mechanism, which provides clear physical insight into each mode at various frequencies. Due to the adoption of textile (i.e., felt) as substrate and nylon conductive fabric as conductor, the proposed antenna is flexible, totally conforming to the curve-shaped human body. The antenna with broadside radiation is suitable for off-body communications. For verification, the prototype operating at 5 GHz (5.15–5.825 GHz) band was fabricated. The measured −10 dB impedance and 3 dB AR bandwidths of 35.1% and 17.5% with a peak gain of 8.5 dBi are achieved. Furthermore, the BCP antenna is used as an element to constitute the WCAA, and the omnidirectional radiation pattern in the azimuth plane is achieved for on- and off-body communications. The considerations about how to achieve omnidirectional radiation and avoid radiation nulls are studied in detail. Finally, the WCAA was fabricated and tested; the measured results guarantee its potential for wearable applications.
20 September 2018 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
A miniaturized four-element multiple-input-multiple-output (MIMO) antenna operating in the band of In-dustrial, Scientific, and Medical (ISM) 2.4-2.48 GHz, is investigated to supply sufficient transmission rate and fight against multipath fading. A single antenna integrates with dual radiators, and each radiator is owned by a pair of sub-antenna units, greatly diminishing the whole dimensions of the implanted MIMO device. A cross-shaped slot etched in the radiator, a branch extending on the conductor ground, and a pair of electromagnetic band gaps (EBGs) are integrated to achieve high isolation. The proposed MIMO antenna has the compact dimensions of 18.5 mm × 18.5 mm × 1.27 mm. The simula-tion in the three-layer phantom indicates that the impedance matching is good with a bandwidth of 18.64% (2.14-2.58 GHz) and a maximum gain of -15.18 dBi and the mutual coupling is reduced to less than -15.99 dB at the ISM band. An ex-vivo test was implemented in a fresh pork slab and the measurement results are well matched with the simulation ones. Health safety considerations and link budget are discussed to validate the antenna's availability in biomedical telemetry, and the envelope correlation coefficient is computed, illustrating the high independence between antenna elements.
5 January 2022 in IEEE Transactions on Antennas and Propagation
A dual-circular polarization (CP) textile antenna is investigated for wearable applications at 3.5 GHz WiMAX and 5.8 GHz industrial, scientific, and medical bands. The proposed antenna is composed of a dual-band monopole antenna and a polarization rotation artificial magnetic conductor (PRAMC). Through the PRAMC, the dual-CP radiation is enabled and the backward radiation is alleviated, in which the left-handed CP is generated in the lower band and the right-handed CP is realized in the upper band. Notably, dyadic reflection coefficient analysis is employed to understand the operating mechanism. Both monopole and PRAMC are printed on textile substrate, achieving conformability and comfortability. In addition, numerical results indicate that the performance of the antenna is robust to lossy human body and structural deformations. For verification, the prototype of the antenna was fabricated by two types of manufacturing process (i.e., laser cutting and screen printing), and the advantages and drawbacks of each fabricating approach are discussed for referring. The antenna made by laser cutting was tested on the phantom with the −10 dB impedance bandwidths of 11.7% and 9.1%, the 3 dB axial ratio bandwidths of 2.0% and 8.2%, and the peak gains of 6.6 and 7.2 dBic, in dual bands, respectively.
8 March 2022 in IEEE Antennas and Wireless Propagation Letters
A wideband circularlypolarized (CP) wearable antenna for 5 GHz (5.15–5.825 GHz) wireless body area network is presented and analyzed. The emphasis of this work is on the additional resonance generated by the mutual coupling of a 2×2 compact patch array. As the proposed antenna is fed by a sequential-phase feeding network, the resonance can be used to achieve unidirectional radiation with improved CP bandwidth. To alleviate the loading effects of the human body, a modified strip feedline, comprising two pairs of arc-shaped slots cut on the bottom ground, is introduced. Moreover, the adoption of textiles as substrate and conductor provides flexibility and conformability, allowing the antenna to be integrated with garments. The prototype with the dimensions of 40 mm × 40 mm × 4 mm (0.73 λ 0 × 0.73 λ 0 × 0.07 λ 0 ) was fabricated. The measured results indicate that a wide impedance bandwidth of 43% (4.25–6.63 GHz), a half-power beamwidth of 60°, and a 3 dB AR bandwidth of 34% (4.71–6.67 GHz) are achieved. Furthermore, the antenna performance is proved to be stable under structural deformation and human body loading. Finally, transmission losses and link budgets are evaluated, enabling the antenna to be a robust solution for off-body communications.
11 November 2019 in IET Microwaves, Antennas & Propagation
A novel differentially fed fractal antenna coated with a layer of a dielectric film and operating at two bands of Medical Implant Communication Services 402–405 MHz and Industrial, Scientific, and Medical 2.4–2.48 GHz, is investigated to enable sufficient data transmission rates, while featuring a ‘mode‐control’ signal to prolong the battery life. The symmetrical fractal technology of Hilbert curve is employed to miniaturise the dimension. To facilitate interfacing with peripheral integrated circuits, differentially feeding is adopted. To demonstrate how common‐mode noises are suppressed, for the first time, a detailed analysis about the noise suppression of the differential configuration with two feedings is presented. A layer of thin film is coated around the proposed antenna to isolate the effect of human tissues and alleviate the electromagnetic coupling with human body. Moreover, to draw a design methodological guideline, the key geometrical parameters are analysed numerically and theoretically. Health safety considerations, radiation performance, and link budgets are also discussed to validate the proposed antenna's applicability in biomedical telemetry.