Rebecca I. Hamilton

Rebecca I. Hamilton

Auto-generated profile, based on publicly available information

Rebecca I. Hamilton

Cardiff University, Cardiff, United Kingdom

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2024 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Open access
RHRebecca I. Hamilton
Rebecca I. Hamilton
ZGZornitza Glavcheva-Laleva
Zornitza Glavcheva-Laleva
IMImdadul Haque Milon
Imdadul Haque Milon
YAYeshwin Anil
Yeshwin Anil
JWJenny Williams
Jenny Williams
CHCatherine Holt
Catherine Holt
Tools to calculate human movement patterns can benefit musculoskeletal clinicians and researchers for rehabilitation assessments. The research objective of this study was to compare two human pose estimation models (HRNet, MediaPipe) against the laboratory marker-based reference standard for joint angles and range of motion (ROM) for several movement parameters. Twenty-two healthy volunteers (Female n = 16, Male n = 6), participated to compare outputs for knee and elbow kinematics. Joint angles were calculated by selecting three marker points defining the joint and angle between them in Qualisys Track Manager software. Using predicted key points, pose estimation model calculations for the same musculoskeletal kinematic outputs were computed. Coefficient of Variation (CoV) was used as a variation statistic for joint angle during movements. All comparison results were under 10%, implying that both models compute reliable joint angle data during the five tested activities. When comparing ROM as a discrete parameter, CoV values remain low, though not all below 10%. Intra-class Correlation Coefficients were computed across the ROM data as a measure of statistical similarity. Each exercise displayed good-excellent and significant correlations for both models compared to Qualisys apart from left knee sit-to-stand. Exploration from this data sampling imply that flexion/extension exercises give stronger consistency results than full sit-to-stand movements when compared to 3D motion analysis, and there is little distinction between these two models. Finer tuning of models will give further reliability for in-depth analysis as these results are restricted, but valuable for a rehabilitative setting with limited objective analysis alternative.

1 January 2022 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Closed access
RHRebecca I. Hamilton
Rebecca I. Hamilton
CGClaire Garden
Claire Garden
SBSusan J. Brown
Susan J. Brown

14 November 2022 in Frontiers in Rehabilitation Sciences
Verified
Journal Article
Open access
RHRebecca I. Hamilton
Rebecca I. Hamilton
JWJenny Williams
Jenny Williams
OCOATech Network+ Consortium
OATech Network+ Consortium
CHCathy Holt
Cathy Holt
The objective of this project is to produce a review of available and validated technologies suitable for gathering biomechanical and functional research data in patients with osteoarthritis (OA), outside of a traditionally fixed laboratory setting. A scoping review was conducted using defined search terms across three databases (Scopus, Ovid MEDLINE, and PEDro), and additional sources of information from grey literature were added. One author carried out an initial title and abstract review, and two authors independently completed full-text screenings. Out of the total 5,164 articles screened, 75 were included based on inclusion criteria covering a range of technologies in articles published from 2015. These were subsequently categorised by technology type, parameters measured, level of remoteness, and a separate table of commercially available systems. The results concluded that from the growing number of available and emerging technologies, there is a well-established range in use and further in development. Of particular note are the wide-ranging available inertial measurement unit systems and the breadth of technology available to record basic gait spatiotemporal measures with highly beneficial and informative functional outputs. With the majority of technologies categorised as suitable for part-remote use, the number of technologies that are usable and fully remote is rare and they usually employ smartphone software to enable this. With many systems being developed for camera-based technology, such technology is likely to increase in usability and availability as computational models are being developed with increased sensitivities to recognise patterns of movement, enabling data collection in the wider environment and reducing costs and creating a better understanding of OA patient biomechanical and functional movement data.


10 November 2022 in Research Square
Verified
Preprint
Open access
PDF file
RHRebecca I. Hamilton
Rebecca I. Hamilton
AGAshly Alava Garcia
Ashly Alava Garcia
JBJake Bowd
Jake Bowd
DHDavid Hamilton
David Hamilton
DMDeborah Mason
Deborah Mason
CHCathy Holt
Cathy Holt
Objective With an increasingly ageing population and osteoarthritis prevalence, the quantification of nociceptive signals responsible for painful movements and individual responses could lead to better treatment and monitoring solutions. Changes in electrodermal activity (EDA) can be detected via changes in skin conductance (SC) and measured using finger electrodes on a wearable sensor, providing objective information for increased physiological stress response. Results To provide EDA response preliminary data, this was recorded with healthy volunteers on an array of activities while receiving a noxious stimulus. This provides a defined scenario that can be utilised as protocol feasibility testing. Raw signal extraction, processing and statistical analysis was performed using mean SC values on all participant data. Extra exploratory analysis on a case study was incorporated using various decomposition tools. The application of the stimuli resulted in a 35% average increase in mean SC with considerable gender differences in SC and self-reported pain scores. Though EDA parameters are a promising tool for nociceptive response indicators, limitations including motion artifact sensitivities and lack of previous movement-based EDA published data result in restricted analysis understanding. Refined processing pipelines with signal decomposition tools will be necessary to incorporate into a protocol that quantifies nociceptive response clinically meaningfully.

11 April 2023 in Orthopaedic Proceedings
Verified
Journal Article
Closed access
RHR. Hamilton
R. Hamilton
CHC. Holt
C. Holt
DHD. Hamilton
D. Hamilton
AGA.A. Garcia
A.A. Garcia
CGC. Graham
C. Graham
DMD. Mason
D. Mason
MEASURING OSTEOARTHRITIS KNEE NOCICEPTION USING PHYSIOLOGICAL AND MOVEMENT RESPONSES AND A DEFINED THERMAL STIMULUS: A PROOF OF CONCEPT STUDY