1 January 2016 in The Journal of Advanced Prosthodontics
Elbashti M, et al. J Adv Prosthodont. 2016 Jun;8(3):219-223. http://dx.doi.org/10.4047/jap.2016.8.3.219
1 July 2020 in The International Journal of Prosthodontics
Manjin Zhang, BDS, DDS/Mariko Hattori, DDS, PhD/Mahmoud E. Elbashti, BDS, MSc, PhD/Yuka I. Sumita, DDS, PhD: Purpose: To assess the feasibility of using an intraoral scanner for data acquisition of maxillectomy defects. Materials and Methods: In 10 patients who had undergone a maxillectomy, the maxillectomy defects in dentate and edentulous maxillary arches were intraorally scanned. Intraoral photographs were also taken using a digital camera for comparison. Results: Adequate scanning was achieved for the nondefect side of the maxilla and for residual teeth. In some cases, it was impossible to scan the maxillectomy defect, especially the deep sites. Conclusion: Improved intraoral scanning technology will increase the feasibility of its use in maxillofacial prosthetics.
1 March 2017 in The International Journal of Prosthodontics
Mahmoud E. Elbashti, BDS, MSc, PhD/Mariko Hattori, DDS, PhD/Sebastian B.M. Patzelt, DMD, MSc, Dr Med Dent Habil, PhD/Dirk Schulze, DMD, MD, PhD/Yuka I. Sumita, DDS, PhD/Hisashi Taniguchi, DDS, PhD: Purpose: The aim of this study was to evaluate the feasibility and accuracy of using an intraoral scanner to digitize edentulous maxillectomy defects. Materials and Methods: A total of 20 maxillectomy models with two defect types were digitized using cone beam computed tomography. Conventional and digital impressions were made using silicone impression material and a laboratory optical scanner as well as a chairside intraoral scanner. The 3D datasets were analyzed using 3D evaluation software. Results: Two-way analysis of variance revealed no interaction between defect types and impression methods, and the accuracy of the impression methods was significantly different (P = .0374). Conclusion: Digitizing edentulous maxillectomy defect models using a chairside intraoral scanner appears to be feasible and accurate.
1 November 2018 in The International Journal of Prosthodontics
Amel M. Aswehlee, BDS, MSc/Mahmoud E. Elbashti, BDS, MSc, PhD/Mariko Hattori, DDS, PhD/Yuka I. Sumita, DDS, PhD/Hisashi Taniguchi, DDS, PhD: Purpose: To evaluate the feasibility and accuracy of noncontact three-dimensional (3D) digitization systems for capturing facial defects. Materials and Methods: A stone model of a facial defect was digitized using high-accuracy industrial computed tomography as a reference scan. The model was also scanned using four different types of noncontact 3D digitizers: a laser beam light-sectioning technology with camera system and three different stereophotogrammetry systems. All 3D images were reconstructed with corresponding software and saved as standard triangulated language (STL) files. The 3D datasets were geometrically evaluated and compared to the reference data using 3D evaluation software. Kruskal-Wallis H tests were performed to assess differences in absolute 3D deviations between scans, with statistical significance defined as P < .05. Results: The four noncontact 3D digitization systems were feasible for digitizing the facial defect model, although the median 3D deviation of the four digitizers varied. There was a significant difference in accuracy among the digitizers (P < .001). Conclusion: Digitization of facial defect models using various noncontact 3D digitizers appears to be feasible and is most accurate with laser beam light-sectioning technology. Further investigations assessing digitization of facial defects among patients are required to clinically verify the results of this study.
1 November 2016 in The International Journal of Prosthodontics
This case report describes the reproduction of the current obturator of a frail elderly patient using the digitization concept. A computed tomography scanner was used to scan the obturator. The virtual model was created using three-dimensional modeling software. The model was printed using a plastic with a low melting point with a fused deposition modeling technique in a three-dimensional printer and then conventionally processed. The definitive obturator was inserted and evaluated for fit, function, and esthetics and was successfully delivered at the second visit. The patient was satisfied with the oral function and esthetics of the reproduced obturator. This case report confirms the effectiveness of digitization in the reproduction of an obturator that enabled satisfactory oral function and esthetics.