1 December 2016 in Biosensors and Bioelectronics
25 April 2018 in Journal of the Electrochemical Society
Wound management involves repeated clinical trips and procedures of lab tests over days. To eliminate this time lag and provide real-time monitoring of a wound's progress, we have designed an enzymatic biosensor for determining uric acid (UA) in wound fluid. Uric Acid is a biomarker, having an established correlation with wounds and their healing. This electrochemical biosensor comprises enzyme urate oxidase (uricase, UOx) entrapped in a polyvinyl alcohol based cationic polymer for enhanced stability. Results show that the use of a redox electron shuttle, ferrocene carboxylic acid (FCA), enabled electron transfer between the enzyme and the transducer. The immobilized uricase in the polymer matrix provided stable continuous measurements at body temperature for a week with minimal deviation. Detection of uric acid in wound fluid has been determined from volumes as low as 0.5–50μL. Studies from different wound samples have shown an average recovery of 107%. The sensor has been interfaced with LMP91000 potentiostat and controlled by CC2650 microcontroller on a Kapton tape-based miniaturized flexible platform.
25 July 2018 in Electroanalysis
24 June 2019 in Journal of the Electrochemical Society
This work reports a bi-enzymatic biosensor for monitoring uric acid (UA) in biofluids extracted from wound, perilesional skin and healthy skin. The biosensor is composed of uricase (UOx) as a biocatalyst for UA oxidation, horseradish peroxidase (HRP) for electron transfer and a nanocomposite of multi-walled carbon nanotubes (MWCNTs) and Au nanoparticles (AuNPs) as the substrate. The bi-enzymatic approach provided a two-fold enhancement in current response, while the nanocomposite facilitated higher enzyme loading and fast electron transfer enabling a 2-fold increase in current response. The biosensor was able to measure UA levels in human wound exudate and in biofluids extracted from perilesional and healthy skin. The biosensor exhibited a lowest detectable concentration of 9.91 μM with a sensitivity of 2.5 nA μM−1. The UA levels in wound exudate and biofluid extract from perilesional skin were 3.7 and 1.2 times higher than in healthy skin. This result opened a potential way to use the biofluid in wound proximity as a biomarker for prolonged measurements, preventing electrode occlusion and sensor fouling by the wound debris. The electrode fouling studies demonstrated that the electrode with adsorbed wound exudate had 1.5 times reduction in current compared to electrode adsorbed with biofluid extract from perilesional skin.
10 June 2019 in Journal of the Electrochemical Society
This work reports a biosensor for monitoring xanthine for potential wound healing assessment. Active substrate of the biosensor has xanthine oxidase (XO) and horseradish peroxidase (HRP) physisorbed on a nanocomposite of multiwalled carbon nanotubes (MWCNT) decorated with gold nanoparticles (AuNP). The presence of HRP provided a two-fold increase in response to xanthine, and a three-fold increase in response to the nanocomposite. With a sensitivity of 155.71 nA μM−1 cm−2 the biosensor offers a detection limit of 1.3 μM, with linear response between 22 μM and 0.4 mM. Clinical sample analyses showed the feasibility of xanthine detection from biofluids in a lesion site due to diffusion of the analyte into surrounding biofluids. Higher concentrations by three-fold were observed from wound proximity, than away from injury, with an average recovery of 110%. Results show the feasibility of monitoring wound severity through longitudinal measurements of xanthine from injured vicinity.
25 October 2017 in ECS Transactions
An enzymatic electrochemical biosensor comprising the enzyme, urate oxidase (uricase, UOx), has been investigated for detection of real-time changes in uric acid. Uric acid (UA) is a key biomarker for monitoring severity of wounds, a complex process initiated to restore tissue damage. With its presence in different bio-fluids, this work explores possibilities of continuous, non-invasive detection of systemic UA levels. Here, hydrolysis of UA was explored to detect the oxidation of its byproduct, H2O2. The role of metal nano-particles was investigated on detection, through cyclic voltammetry. Use of a redox electron shuttle, ferrocene carboxylic acid (FCA), was seen to enable electron transfer between the active site of the enzyme and the electrode. The constructed enzymatic uric acid biosensor provided a sensitivity of 0.14 µA µM-1 cm-2 and detection limit of 14µM within the physiologically relevant range. This biosensor has the potential of providing wound care through continual systemic UA monitoring.