Andreas G. Reisinger

Andreas G. Reisinger

Auto-generated profile, based on publicly available information

Andreas G. Reisinger

Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-straße 30, 3500, Krems, Austria; Institute of Lightweight Design and Structural Biomechanics, Technische Universität Wien, Vienna, Austria

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
SESarah-Jane Estermann
Sarah-Jane Estermann
DPDieter H. Pahr
Dieter H. Pahr
ARAndreas Reisinger
Andreas Reisinger
In order to create accurate anatomical models for medical training and research, mechanical properties of biological tissues need to be studied. However, non-linear and viscoelastic behaviour of most soft biological tissues complicates the evaluation of their mechanical properties. In the current study, a method for measuring hyperelasticity and viscoelasticity of bovine and porcine hepatic parenchyma in tension is presented. First, non-linear stress-stretch curves resulting from ramp loading and unloading, were interpreted based on a hyperelastic framework, using a Veronda-Westmann strain energy function. Strain-specific elastic moduli, such as initial stiffness EI, were thereupon defined in certain parts of the stress-stretch curves. Furthermore, dissipated and stored energy density were calculated. Next, the viscoelastic nature of liver tissue was examined with two different methods: stress relaxation and dynamic cyclic testing. Both tests yielded dissipated and stored energy density, as well as loss tangent (tanδ), storage modulus (E'), and loss modulus (E''). In tension, stress relaxation was experimentally more convenient than dynamic cyclic testing. Thus we considered whether relaxation could be used for approximating the results of the cyclic tests. Regarding the resulting elastic moduli, initial stiffness was similar for porcine and bovine liver (EI∼30kPa), while porcine liver was stiffer for higher strains. Comparing stress relaxation with dynamic cyclic testing, tanδ of porcine and bovine liver was the same for both methods (tanδ=0.05-0.25 at 1 Hz). Storage and loss moduli matched well for bovine, but not as well for porcine tissue. In conclusion, the utilized Veronda-Westmann model was appropriate for representing the hyperelasticity of liver tissue seen in ramp tests. Concerning viscoelasticity, both chosen testing methods - stress relaxation and dynamic cyclic testing - yielded comparable results for E', E'', and tanδ, as long as elasticity non-linearities were heeded. The here presented method provides novel insight into the tensile viscoelastic properties of hepatic tissue, and provides guidelines for convenient evaluation of soft tissue mechanical properties.

1 July 2021 in Annals of Anatomy - Anatomischer Anzeiger
Verified
Journal Article
Open access
SESarah-Jane Estermann
Sarah-Jane Estermann
SFSophie Förster-Streffleur
Sophie Förster-Streffleur
LHLena Hirtler
Lena Hirtler
JSJohannes Streicher
Johannes Streicher
DPDieter H. Pahr
Dieter H. Pahr
ARAndreas Reisinger
Andreas Reisinger
In medical training and research fresh human tissue is often replaced by preserved human or fresh animal tissue, due to availability and ethical reasons. Newer preservation approaches, such as the Thiel method, promise more realistic mechanical properties than conventional formaldehyde fixation. Concerning animal substitute material, porcine and bovine tissue is often chosen, as it is easily obtainable and certain similarity to human tissue is assumed. However, it has not been thoroughly investigated how Thiel preservation changes non-linear and viscoelastic behaviour of soft organ tissues. Furthermore, differences in these properties between animal tissue and human tissue have not been previously corroborated. We conducted ramp and relaxation tensile tests on fresh human and Thiel preserved hepatic tissue, extracting strain-specific elastic moduli, and viscoelastic properties. The results for fresh human liver were then compared to corresponding results for Thiel preserved liver, as well as previously published results for porcine and bovine liver. Our results showed that Thiel preservation seems to be associated with increased stiffness as well as decreased viscoelastic damping behaviour. Porcine liver was stiffer than human liver with similar viscoelastic properties. Bovine liver exhibited similar stiffness as human liver, however lower viscoelastic damping. The differences between human and animal liver tissue, concerning their mechanical properties, can be explained by their characteristic histology. Changes in mechanical properties due to Thiel preservation might stem from altered protein cross-linking and dehydration. The results illustrate that appropriate materials for medical training systems must be selected based on which mechanical properties are relevant for the respective application.

2 May 2021 in JBMR Plus
Verified
Journal Article
Open access
PDF file
MFMartin Frank
Martin Frank
ARAndreas G Reisinger
Andreas G Reisinger
DPDieter H Pahr
Dieter H Pahr
PTPhilipp J Thurner
Philipp J Thurner
Osteoporosis is the most common bone disease and is conventionally classified as a decrease of total bone mass. Current diagnosis of osteoporosis is based on clinical risk factors and dual energy X‐ray absorptiometry (DEXA) scans, but changes in bone quantity (bone mass) and quality (trabecular structure, material properties, and tissue composition) are not distinguished. Yet, osteoporosis is known to cause a deterioration of the trabecular network, which might be related to changes at the tissue scale—the material properties. The goal of the current study was to use a previously established test method to perform a thorough characterization of the material properties of individual human trabeculae from femoral heads in cyclic tensile tests in a close to physiologic, wet environment. A previously developed rheological model was used to extract elastic, viscous, and plastic aspects of material behavior. Bone morphometry and tissue mineralization were determined with a density calibrated micro‐computed tomography (μCT) set‐up. Osteoporotic trabeculae neither showed a significantly changed material or mechanical behavior nor changes in tissue mineralization, compared with age‐matched healthy controls. However, donors with osteopenia indicated significantly reduced apparent yield strain and elastic work with respect to osteoporosis, suggesting possible initial differences at disease onset. Bone morphometry indicated a lower bone volume to total volume for osteoporotic donors, caused by a smaller trabecular number and a larger trabecular separation. A correlation of age with tissue properties and bone morphometry revealed a similar behavior as in osteoporotic bone. In the range studied, age does affect morphometry but not material properties, except for moderately increased tissue strength in healthy donors and moderately increased hardening exponent in osteoporotic donors. Taken together, the distinct changes of trabecular bone quality in the femoral head caused by osteoporosis and aging could not be linked to suspected relevant changes in material properties or tissue mineralization. © 2021 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

1 January 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
SESarah-Jane Estermann
Sarah-Jane Estermann
DPDieter H. Pahr
Dieter H. Pahr
ARAndreas Reisinger
Andreas Reisinger
Anatomical models for research and education are often made of artificial materials that attempt to mimic biological tissues in terms of their mechanical properties. Recent developments in additive manufacturing allow tuning mechanical properties with microstructural designs. We propose a strategy for designing material microstructures to mimic soft tissue viscoelastic behaviour, based on a micromechanical Mori-Tanaka model. The model was applied to predict homogenised viscoelastic properties of materials, exhibiting a matrix-inclusion microstructure with varying inclusion volume fractions. The input properties were thereby obtained from compression relaxation tests on silicone elastomers. Validation of the model was done with experimental results for composite samples. Finally, different combinations of silicones were compared to mechanical properties of soft tissues (hepatic, myocardial, adipose, cervical, and prostate tissue), found in literature, in order to design microstructures for replicating these tissues in terms of viscoelasticity. The viscoelastic Mori-Tanaka model showed good agreement with the corresponding experimental results for low inclusion volume fractions, while high fractions lead to underestimation of the complex modulus by the model. Predictions for the loss tangent were reasonably accurate, even for higher inclusion volume fractions. Based on the model, designs for 3D printed microstructures can be extracted in order to replicate the viscoelastic properties of soft tissues.

6 May 2020 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
ARAndreas G. Reisinger
Andreas G. Reisinger
MFMartin Frank
Martin Frank
PTPhilipp J. Thurner
Philipp J. Thurner
DPDieter H. Pahr
Dieter H. Pahr
The ability to measure bone tissue material properties plays a major role in diagnosis of diseases and material modeling. Bone’s response to loading is complex and shows a viscous contribution to stiffness, yield and failure. It is also ductile and damaging and exhibits plastic hardening until failure. When performing mechanical tests on bone tissue, these constitutive effects are difficult to quantify, as only their combination is visible in resulting stress–strain data. In this study, a methodology for the identification of stiffness, damping, yield stress and hardening coefficients of bone from a single cyclic tensile test is proposed. The method is based on a two-layer elasto-visco-plastic rheological model that is capable of reproducing the specimens’ pre- and postyield response. The model’s structure enables for capturing the viscously induced increase in stiffness, yield, and ultimate stress and for a direct computation of the loss tangent. Material parameters are obtained in an inverse approach by optimizing the model response to fit the experimental data. The proposed approach is demonstrated by identifying material properties of individual bone trabeculae that were tested under wet conditions. The mechanical tests were conducted according to an already published methodology for tensile experiments on single trabeculae. As a result, long-term and instantaneous Young’s moduli were obtained, which were on average 3.64 GPa and 5.61 GPa, respectively. The found yield stress of 16.89 MPa was lower than previous studies suggest, while the loss tangent of 0.04 is in good agreement. In general, the two-layer model was able to reproduce the cyclic mechanical test data of single trabeculae with an root-mean-square error of 2.91 ± 1.77 MPa. The results show that inverse rheological modeling can be of great advantage when multiple constitutive contributions shall be quantified based on a single mechanical measurement.

1 February 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
OAOthniel J. Aryeetey
Othniel J. Aryeetey
MFMartin Frank
Martin Frank
ALAndrea Lorenz
Andrea Lorenz
SESarah-Jane Estermann
Sarah-Jane Estermann
ARAndreas G. Reisinger
Andreas G. Reisinger
DPDieter H. Pahr
Dieter H. Pahr
Mechanical characterisation of soft viscous materials is essential for many applications including aerospace industries, material models for surgical simulation, and tissue mimicking materials for anatomical models. Constitutive material models are, therefore, necessary to describe soft biological tissues in physiologically relevant strain ranges. Hereby, the adaptive quasi-linear viscoelastic (AQLV) model enables accurate modelling of the strain-dependent non-linear viscoelastic behaviour of soft tissues with a high flexibility. However, the higher flexibility produces a large number of model parameters. In this study, porcine muscle and liver tissue samples were modelled in the framework of the originally published AQLV (3-layers of Maxwell elements) model using four incremental ramp-hold experiments in uniaxial tension. AQLV model parameters were reduced by decreasing model layers (M) as well as the number of experimental ramp-hold steps (N). Leave One out cross validation tests show that the original AQLV model (3M4N) with 19 parameters, accurately describes porcine muscle tissue with an average R2 of 0.90 and porcine liver tissue, R2 of 0.86. Reducing the number of layers (N) in the model produced acceptable model fits for 1-layer (R2 of 0.83) and 2-layer models (R2 of 0.89) for porcine muscle tissue and 1-layer (R2 of 0.84) and 2-layer model (R2 of 0.85) for porcine liver tissue. Additionally, a 2 step (2N) ramp-hold experiment was performed on additional samples of porcine muscle tissue only to further reduce model parameters. Calibrated spring constant values for 2N ramp-hold tests parameters k1 and k2 had a 16.8% and 38.0% deviation from those calibrated for a 4 step (4N) ramp hold experiment. This enables further reduction of material parameters by means of step reduction, effectively reducing the number of parameters required to calibrate the AQLV model from 19 for a 3M4N model to 8 for a 2M2N model, with the added advantage of reducing the time per experiment by 50%. This study proposes a 'reduced-parameter' AQLV model (2M2N) for the modelling of soft biological tissues at finite strain ranges. Sequentially, the comparison of model parameters of soft tissues is easier and the experimental burden is reduced.