Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
We experimentally demonstrate an efficient electro-optic sampling scheme based on Cherenkov phase matching of broadband terahertz radiation with 800-nm femtosecond probe beam in a 0.5 mm-thick LiNbO3 crystal coupled to a Si prism. The electro-optic signal from a Cherenkov-phase-matched LiNbO3 crystal is found to be comparable to that with a 4 mm-thick ZnTe crystal using a collinear phase matching. The Cherenkov phase matching technique can be achieved with any probe wavelength and hence has an advantage over the collinear phase matching method.
1 November 2009 in Review of Scientific Instruments
Experimental results are presented on the neutron scintillating properties of a custom-designed -doped lithium (Li) glass. Luminescence was observed at 278 nm wavelength, originating from the transition. Time-resolved measurements yielded about 20 ns decay times for ultraviolet and x-ray excitation while much faster decay times of about 6 ns were observed for alpha particle and neutron excitation. Actual time-of-flight data in laser fusion experiments at the GEKKO XII facility of the Institute of Laser Engineering, Osaka University reveal that it can clearly discriminate fusion neutrons from the much stronger x-rays signals. This material can promise improved accuracy in future scattered neutron diagnostics.
A new electro-optic (EO) sampling scheme, which we refer to as “heterodyne EO sampling”, for detection of pulsed terahertz (THz) waves is proposed and experimentally demonstrated. In this heterodyne EO sampling scheme, the intensity change in the optical probe pulse induced by a THz field in a nonlinear crystal is measured without any polarization optics. Applied in combination with the non-collinear Cherenkov velocity matching technique, this method allows one to detect pulsed THz waves efficiently and easily using a simpler optical setup as compared to the conventional ellipsometric EO sampling method.
For pump and probe experiments in x-ray free-electron laser (XFEL) facilities, accurate timing synchronization between short-wavelength femtosecond pulses from XFELs and short optical pulses from other light sources is required. For this purpose, the response time of a hydrothermal-method-grown ZnO is improved by over one order of magnitude via intentional iron ion doping. The fluorescence rise- and decay-time constants are measured to be less than 10 and 100 ps, respectively. Owing to its intense fluorescence even for single pulse XFEL excitation, the timing jitter of the soft x-ray pulse and timing electronics are evaluated to be less than 70 ps.