Giulio D'Acunto

Giulio D'Acunto

Auto-generated profile, based on publicly available information

Giulio D'Acunto

Department of Chemical Engineering, Stanford University, 450 Jane Stanford Way, Stanford, California 94305, United States

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
SZSuyun Zhu
Suyun Zhu
MSMattia Scardamaglia
Mattia Scardamaglia
JKJan Kundsen
Jan Kundsen
RSRami Sankari
Rami Sankari
HTHamed Tarawneh
Hamed Tarawneh
ASAndrey Shavorskiy
Andrey Shavorskiy
HIPPIE is a soft X-ray beamline on the 3 GeV electron storage ring of the MAX IV Laboratory, equipped with a novel ambient-pressure X-ray photoelectron spectroscopy (APXPS) instrument. The endstation is dedicated to performing in situ and operando X-ray photoelectron spectroscopy experiments in the presence of a controlled gaseous atmosphere at pressures up to 30 mbar [1 mbar = 100 Pa] as well as under ultra-high-vacuum conditions. The photon energy range is 250 to 2200 eV in planar polarization and with photon fluxes >1012 photons s−1 (500 mA ring current) at a resolving power of greater than 10000 and up to a maximum of 32000. The endstation currently provides two sample environments: a catalysis cell and an electrochemical/liquid cell. The former allows APXPS measurements of solid samples in the presence of a gaseous atmosphere (with a mixture of up to eight gases and a vapour of a liquid) and simultaneous analysis of the inlet/outlet gas composition by online mass spectrometry. The latter is a more versatile setup primarily designed for APXPS at the solid–liquid (dip-and-pull setup) or liquid–gas (liquid microjet) interfaces under full electrochemical control, and it can also be used as an open port for ad hoc-designed non-standard APXPS experiments with different sample environments. The catalysis cell can be further equipped with an IR reflection–absorption spectrometer, allowing for simultaneous APXPS and IR spectroscopy of the samples. The endstation is set up to easily accommodate further sample environments.

1 June 2021 in Applied Surface Science
Verified
Journal Article
Open access
ZYZhihua Yong
Zhihua Yong
KPKarl-Magnus Persson
Karl-Magnus Persson
MRMamidala Saketh Ram
Mamidala Saketh Ram
GDGiulio D'Acunto
Giulio D'Acunto
YLYi Liu
Yi Liu
RTRainer Timm
Rainer Timm

21 October 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
JKJan Knudsen
Jan Knudsen
TGTamires Gallo
Tamires Gallo
VBVirgínia Boix
Virgínia Boix
MSMarie Døvre Strømsheim
Marie Døvre Strømsheim
GDGiulio D’aCunto
Giulio D’aCunto
JSJoachim Schnadt
Joachim Schnadt
Heterogeneous catalyst surfaces are dynamic entities that respond rapidly to changes in their local gas environment, and the dynamics of the response is a decisive factor for the catalysts’ action and activity. Few probes are able to map catalyst structure and local gas environment simultaneously under reaction conditions at the timescales of the dynamic changes. Here we use the CO oxidation reaction and a Pd(100) model catalyst to demonstrate how such studies can be performed by time-resolved ambient pressure photoelectron spectroscopy. Central elements of the method are cyclic gas pulsing and software-based event-averaging by image recognition of spectral features. A key finding is that at 3.2 mbar total pressure a metallic, predominantly CO-covered metallic surface turns highly active for a few seconds once the O2:CO ratio becomes high enough to lift the CO poisoning effect before mass transport limitations triggers formation of a √5 oxide.

18 November 2020 in ACS Applied Electronic Materials
Verified
Journal Article
Closed access
GDGiulio D’acunto
Giulio D’acunto
ATAndrea Troian
Andrea Troian
EKEsko Kokkonen
Esko Kokkonen
FRFoqia Rehman
Foqia Rehman
YLYen-Po Liu
Yen-Po Liu
RTRainer Timm
Rainer Timm

1 November 2018 in Carbon
Verified
Journal Article
Closed access
GDGiulio D'Acunto
Giulio D'Acunto
FRFrancesca Ripanti
Francesca Ripanti
P. PostorinoP. Postorino
P. Postorino
MBMaria Grazia Betti
Maria Grazia Betti
MSMattia Scardamaglia
Mattia Scardamaglia
Carlo MarianiCarlo Mariani
Carlo Mariani

30 September 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
ASAndrey Shavorskiy
Andrey Shavorskiy
GDGiulio D’aCunto
Giulio D’aCunto
VCVirginia Boix de la Cruz
Virginia Boix de la Cruz
MSMattia Scardamaglia
Mattia Scardamaglia
SZSuyun Zhu
Suyun Zhu
JKJan Knudsen
Jan Knudsen
A setup capable of conducting gas pulse–X-ray probe ambient pressure photoelectron spectroscopy with high time resolution is presented. The setup makes use of a fast valve that creates gas pulses with an internal pressure in the mbar range and a rising edge of few hundreds of microseconds. A gated detector based on a fast camera is synchronized with the valve operation to measure X-ray photoemission spectra with up to 20 μs time resolution. The setup is characterized in several experiments in which the N2 gas is pulsed either into vacuum or a constant flow of another gas. The observed width of the pulse rising edge is 80 μs, and the maximum internal pulse pressure is ∼1 mbar. The CO oxidation reaction over Pt (111) was used to demonstrate the capability of the setup to correlate the gas phase composition with that of the surface during transient supply of CO gas into an O2 stream. Thus, formation of both chemisorbed and oxide oxygen species was observed prior to CO gas perturbation. Also, the data indicated that both the Langmuir–Hinshelwood and Mars-van-Krevelen mechanisms play an important role in the oxidation of carbon monoxide under ambient conditions.