Mariana Picca

Mariana Picca

Auto-generated profile, based on publicly available information

Mariana Picca

Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Materiales Dentales, Buenos Aires, Argentina

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2023 in Acta Odontológica Latinoamericana
Verified
Journal Article
Open access
MLMaría A Lei
María A Lei
RMRicardo L Macchi
Ricardo L Macchi
MPMariana Picca
Mariana Picca
During ceramic veneer luting, resin cement polymerization is performed with interposition of the dental ceramic. Aim: To evaluate how and how much the photoactivation time affects the Vickers hardness of resin-based cements with interposed ceramic. Materials and Method: A total 24 specimens 11 mm in diameter and 1 mm thick were made from Paracore White Coltene (PC), Densell Resin Duo Cement (DC), 3M RelyX Veneer (RX) and Coltene Fill Up! (FU), interposing Vitablock Mark II (Vita Zahnfabrik) feldspathic ceramic 0.6 mm thick during photoactivation. The materials were polymerized using 100% and 25% of the times indicated by the manufacturers with a Coltolux LED (Coltene) light with intensity 1200 mW/cm2 . Each polymerization time group consisted of three specimens of each material, which were stored dry in darkness at 37 °C for 7 days. Three Vickers microhardness measurements were made on the top and bottom surfaces of each specimen using a Vickers Future Tech FM300 microhardness tester (300 g, 5 s). The values were averaged, and the bottom/top ratios calculated. Results were analyzed by ANOVA. (p<0.05) complemented with multiple comparisons using Tukey’s test (p<0.05). Results: Different photoactivation times were found to have a significant effect on hardness values of the cements evaluated, with significant differences between some of the cements. No statistically significant difference was found for the effect of photoactivation time on bottom/top microhardness ratio in those materials. Conclusions: Under the experimental conditions employed, it can be concluded that photopolymerization for shorter times and the interposition of restorative material significantly affect polymerization quality as evaluated by microhardness, but the bottom/top ratio was unaffected by differences in polymerization time.

1 September 2020 in Acta Odontológica Latinoamericana
Verified
Journal Article
Open access
MRMarcela Roitman
Marcela Roitman
MPMariana Picca
Mariana Picca
RMRicardo Macchi
Ricardo Macchi
The aim of this study was to evaluate the ability of different irrigation protocols to remove from the walls of the root canal and entrance to dentinal tubules the smear layer produced during preparation for a fiber post. Fifty decoronated human lower premolars were treated endodontically and the apical third of the canal was filled with a single gutta-percha point using warm vertical compaction. Ten millimeters were left free for post preparation, which was done by sequential use of a Largo #1 drill and Exacto #3 pilot drill (Angelus, Brazil), with irrigation with distilled water upon each instrument change. Samples were distributed randomly into 5 groups (n=10). G 1: No irrigation after post preparation. G 2: Distilled water activated for 60 s + distilled water. G 3: 5.25% NaOCl 15 s+ distilled water. G 4: 17% EDTA (Farmadental, Argentina) 60 s + 5.25% NaOCl 15 s + distilled water. G 5: 10% polyacrylic acid (Densell) 15 s + distilled water. Irrigant was activated mechanically with a low-speed conical brush. Roots were then split longitudinally in vestibular-lingual direction. Each surface was observed under SEM in its different thirds. Microphotographs were taken at 150X and 600X magnification and results analyzed statistically using Kruskall Wallis and Friedman tests (p<0.05). The results [mean (standard deviation)] were: for 150X: G1 11.00 (1.33), G2 7.50 (3.13), G3 6.30 (2.58), G4 2.20 (2.80), G5 4.30 (1.50), and for 600X G1 11.40 (0.84), G2 10.00 (1.94), G3 7.70 (3.33), G4 5.80 (3.70), G5 7.20 (2.65). The statistical analysis showed significant differences between irrigants (p0.05). The EDTA+NaOCl combination and polyacrylic acid showed greater capacity to remove the smear layer created during post preparation.

9 October 2024 in Revista de la Facultad de Odontologia. Universidad de Buenos Aires
Verified
Journal Article
Open access
PDF file
JAJimena Anchava
Jimena Anchava
GCGabriela Cortese
Gabriela Cortese
AGAnalia Garrofé
Analia Garrofé
MPMariana Picca
Mariana Picca
ABAna Biondi
Ana Biondi
El objetivo de este trabajo fue comparar clínicamente el tiempo requerido, la dificultad de la técnica y la longevidad de restauraciones oclusales en molares primarios vitales utilizando resina tipo bulk-fill de alta y baja viscosidad. Se realizaron restauraciones de lesiones amelodentinarias oclusales en molares primarios vitales sin movilidad, con remanente de estructura dental que no cediera ante cargas oclusales con una extensión en profundidad no mayor a 4 mm, en pacientes de entre 2 y 10 años. Se asignaron aleatoriamente a dos grupos: bulk-fill de alta viscosidad (Grupo control - BF) y bulk-fill de baja viscosidad (Grupo experimental - BFF). Todas las restauraciones fueron evaluadas clínicamente por tres operadores (Kappa > 0,7) en situaciones basales y a los 6 meses siguiendo los criterios RYGE/USPHS modificados. Se realizaron 67 preparaciones en 54 pacientes (edad media 7,09+1,95 años) sin diferencias en relación a las dimensiones de las preparaciones cavitarias. El tiempo requerido fue menor para BFF (p=0,001). La dificultad en la manipulación fue 2,33+0,57 para BF y 1+0,00 para BFF según la escala de Likert. A los 6 meses en ambos grupos, se clasificaron como alfa la decoloración marginal, la integridad de los márgenes y la ausencia de caries secundaria. El comportamiento clínico no registró diferencias significativas entre ambos grupos (p>0,05). En esta muestra el comportamiento clínico de las resinas bulk-fill de baja viscosidad se encontró dentro de parámetros aceptables, pero con una significativa disminución del tiempo operatorio y menor índice de dificultad. Se necesitarán evaluaciones a más largo plazo.

1 September 2021 in Acta Odontológica Latinoamericana
Verified
Journal Article
Open access
OZOsvaldo Zmener
Osvaldo Zmener
CPCornelis H. Pameijer
Cornelis H. Pameijer
ABAna Boetto
Ana Boetto
MPMariana Picca
Mariana Picca
The aim of this descriptive ex vivo study was to evaluate qualitatively the depth of pit and fissures (P&F) of the enamel in human mandibular third molars. Fifty (n=50) extracted human mandibular third molars were cleaned and disinfected. All tooth surfaces were coated with nail varnish except for a 1-mm margin around the periphery of the occlusal surface. The teeth were immersed for 48 hours at 37 °C in 1% methylene blue dye solution prepared in artificial saliva. After cleaning, the crowns were separated from the root at the cementoenamel junction and subsequently sectioned longitudinally in buccolingual direction at the location of the central fossa. All sections were examined using a stereoscopic microscope and photographed. The images were downloaded on a computer. The length of penetration of the P&F was recorded using the following scoring system: C1: P&F extended to half of the enamel thickness; C2: P&F extended beyond half of the enamel thickness without reaching the dentine-enamel junction; C3: P&F extended to the dentine-enamel junction. For pits, C1, C2 and C3 were observed in 35, 9 and 6 teeth, respectively, while for fissures, C1, C2 and C3 were observed in 15, 18 and 17 teeth, respectively. The P&F detected in the samples extended to the deepest portions of enamel, quite frequently reaching the enamel-dentine junction. Clinicians should recognize that even if pits and fissures are not clinically obvious, they penetrate deep into the enamel and frequently reach the dentine-enamel junction. Effective treatment is recommended to block access to P&F, thus preventing ingress of bacteria.

3 March 2026 in Revista de la Facultad de Odontologia. Universidad de Buenos Aires
Verified
Journal Article
Open access
MIMaría Emilia Iglesias
María Emilia Iglesias
PAP F Abate
P F Abate
MCM Alvarez Castro
M Alvarez Castro
ACA Capusotto
A Capusotto
SCS P Cattaneo
S P Cattaneo
PRPablo Alejandro Rodriguez
Pablo Alejandro Rodriguez
La incorporación de las técnicas adhesivas como standard of care al flujo de trabajo de la clínica odontológica ha modificado prácticamente todas las etapas del tratamiento dental, desde el diagnóstico hasta el mantenimiento de las restauraciones. En el caso de las restauraciones indirectas, la fijación adhesiva tiene como objetivo la integración del bloque restaurador con el remanente dentario y con los materiales que hayan sido necesarios para la conformación de la preparación. Los aspectos fundamentales para alcanzar el éxito clínico en restauraciones estéticas adheridas incluyen: la identificación de la magnitud de fijación requerida en el caso; el control del campo operatorio (incluido el vapor de agua del aire exhalado); la preparación del sustrato orientada para la máxima conservación de tejido dentario y la minimización de las tensiones de corte y flexión; la selección del medio de fijación o cemento (términos que serán considerados sinónimos) adecuado al espesor y transmitancia del material restaurador; el tratamiento de la superficie interna de la restauración y del sustrato dentario (y no dentario) para generar interacción mecánica y/o química con el cemento elegido, de acuerdo con el protocolo correspondiente; y el control de la oclusión. La diversidad de materiales disponibles, junto con la sensibilidad técnica del procedimiento, ha generado una considerable variabilidad en los protocolos clínicos de fijación. En este contexto, el presente consenso propone una sistematización de los pasos clínicos involucrados en la fijación adhesiva de restauraciones estéticas indirectas basada en la mejor evidencia científica disponible, con el objetivo de favorecer procedimientos más predecibles y reproducibles en la práctica odontológica.

14 August 2021 in Revista de la Asociación Odontológica Argentina
Verified
Journal Article
Open access
PDF file
OZOsvaldo Zmener
Osvaldo Zmener
PEPablo Ensinas
Pablo Ensinas
MPMariana Picca
Mariana Picca
RPRoberto Della Porta
Roberto Della Porta
Objetivo:Comparar la microdureza de dos materiales endodónticos a base de silicato de calcio: MTA Densell Endo Sealer y TotalFill BC Sealer. Materiales y métodos: Se evaluó la microdureza de los selladores MTA Densell Endo Sealer (Grupo 1, n=5) y TotalFill BC Sealer (Grupo 2, n=5) contenidos en cilindros de dentina de vacuno a los 14 días posteriores a su fraguado. La medición se realizó a temperatura ambiente mediante la prueba de indentación Vickers. Se realizaron cinco indentaciones por probeta con una carga de 100 g durante 10 s cada una. Las mediciones se convirtieron a valores de dureza Vickers (HV) y los promedios de los valores HV de cada grupo se compararon por medio de la prueba t de Student con un nivel de significación de P <0,05. Resultados: A los 14 días, luego del fraguado, la microdureza de MTA Densell Endo Sealer fue significativamente mayor (P=0,001) que la de TotalFill BC Sealer. Conclusiones: Los resultados sugieren que a causa de su dureza la remoción de MTA Densell Endo Sealer puede resultar dificultosa cuando está indicado un retratamiento.