Nathalie Guigues

Nathalie Guigues

Auto-generated profile, based on publicly available information

Nathalie Guigues

Laboratoire National de métrologie et d’Essais (LNE), Paris, France

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2015 in Accreditation and Quality Assurance
Verified
Journal Article
Closed access
PDF file
NGNathalie Guigues
Nathalie Guigues
MDMichèle Desenfant
Michèle Desenfant
BLBéatrice Lalere
Béatrice Lalere
SVSophie Vaslin-Reimann
Sophie Vaslin-Reimann
DEDamien Eyl
Damien Eyl
EHEmmanuel Hance
Emmanuel Hance

5 August 2013 in Environmental Science: Processes & Impacts
Verified
Journal Article
Closed access
PDF file
NGNathalie Guigues
Nathalie Guigues
MDMichèle Desenfant
Michèle Desenfant
EHEmmanuel Hance
Emmanuel Hance
The objective of this paper was to demonstrate how multivariate statistics combined with the analysis of variance could support decision-making during the process of redesigning a water quality monitoring network with highly heterogeneous datasets in terms of time and space. Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) were selected to optimise the selection of water quality parameters to be monitored as well as the number and location of monitoring stations. Sampling frequency was specifically investigated through the analysis of variance. The data used were obtained between 2007 and 2010 at the Long-term Environmental Research Monitoring and Testing System (OPE) located in the north-eastern part of France in relation with a geological disposal of radioactive waste project. PCA results showed that no substantial reduction among the parameters was possible as strong correlation only exists between electrical conductivity, calcium or bicarbonates. HCA results were geospatially represented for each field campaign and compared to one another in terms of similarities and differences allowing us to group the monitoring stations into 12 categories. This approach enabled us to take into account not only the spatial variability of water quality but also its temporal variability. Finally, the analysis of variances showed that three very different behaviours occurred: parameters with high temporal variability and low spatial variability (e.g. suspended matter), parameters with high spatial variability and average temporal variability (e.g. calcium) and finally parameters with both high temporal and spatial variability (e.g. nitrate).

11 June 2024 in The Analyst
Verified
Journal Article
Open access
PDF file
SLSerena Laschi
Serena Laschi
PSPatrick Severin Sfragano
Patrick Severin Sfragano
FTFrancesco Tadini-Buoninsegni
Francesco Tadini-Buoninsegni
NGNathalie Guigues
Nathalie Guigues
Ilaria PalchettiIlaria Palchetti
Ilaria Palchetti
Aim: obtain a field-deployable portable box for the online detection of heavy metals in water through an automatable software-assisted procedure and square-wave anodic stripping voltammetry.

14 March 2022 in SN Applied Sciences
Verified
Journal Article
Open access
PDF file
NGNathalie Guigues
Nathalie Guigues
SLSophie Lardy-Fontan
Sophie Lardy-Fontan
AVAurélie Villeneuve
Aurélie Villeneuve
PMPhilippe Mansuit
Philippe Mansuit
SWSandra Welsch
Sandra Welsch
BLBéatrice Lalere
Béatrice Lalere
The study presents an alternative strategy to conventional spot sampling for monitoring metals and polycyclic aromatic hydrocarbons (PAHs) at an upstream, rural and karstic catchment in the north eastern part of France, in order to get insight into their spatial and temporal variability. Passive samplers, as diffusive gradients in thin films (DGT) and semipermeable membrane device (SPMD), are monthly deployed from August 2012 to March 2016 at five of the catchment monitoring stations located on the Saulx and Ornain Rivers. An improvement of the frequency of quantification (by a factor 2 to 8, depending on the targeted compound) is observed allowing us to better identify spatial and temporal variability. For instance, the upstream monitoring station on the Saulx River is characterized by high concentrations of Ni and Mn whereas the upstream monitoring station on the Ornain River is enriched in Cu and Zn. Furthermore, five metals (Al, Fe, Mn, Ni, Zn) and three PAHs (fluoranthene, pyrene and chrysene) show significant variations with water levels when grouped in three categories (low, medium and high water levels) in relation with hydrological and climatic patterns. This study leads to a more accurate assessment of the background pollution in metals and PAHs within surface waters than when based on spot sampling data.

8 February 2024 in Accreditation and Quality Assurance
Verified
Journal Article
Closed access
PDF file
NGNathalie Guigues
Nathalie Guigues
EUEmrah Uysal
Emrah Uysal
SRSandrine Raveau
Sandrine Raveau
JMJérémie Magar
Jérémie Magar
GBGabriel Billon
Gabriel Billon
BLBéatrice Lalere
Béatrice Lalere

12 June 2020 in Accreditation and Quality Assurance
Verified
Journal Article
Closed access
PDF file
NGNathalie Guigues
Nathalie Guigues
BLBénédicte Lepot
Bénédicte Lepot
MDMichèle Desenfant
Michèle Desenfant
JDJacky Durocher
Jacky Durocher