We have studied the temporal coherence of high-order harmonics (up to the 15th order) produced by focusing 100 fs laser pulses into an argon gas jet. We measure the visibility of the interference fringes, produced when two spatially separated harmonic sources interfere in the far field, as a function of the time delay between the two sources. In general, we find long coherence times, comparable to the expected pulse durations of the harmonics. For some of the harmonics, the interference pattern exhibits two regions, with significantly different coherence times. These results are interpreted in terms of different electronic trajectories contributing to harmonic generation.
In this paper we present the laboratory characterization and performance evaluation of the First Light Adaptive Optics (FLAO) the Natural Guide Star adaptive optics system for the Large Binocular Telescope (LBT). The system uses an adaptive secondary mirror with 672 actuators and a pyramid wavefront sensor with adjustable sampling of the telescope pupil from 30×30 down to 4×4 subapertures. The system was fully assembled in the Arcetri Observatory laboratories, passing the acceptance test in December 2009. The performance measured during the test were closed to goal specifications for all star magnitudes. In particular FLAO obtained 83% Strehl Ratio (SR) in the bright end (8.5 magnitudes star in R band) using H band filter and correcting 495 modes with 30×30 subapertures sampling. In the faint end (16.4 magnitude) a 5.0% SR correcting 36 modes with 7×7 subapertures was measured. The seeing conditions for these tests were 0.8" (r0 = 0.14m @ 550 nm) and an average wind speed of 15m/s. The results at other seeing conditions up to 1.5" are also presented. The system has been shipped to the LBT site, and the commissioning is taking place since March to December 2010. A few on sky results are presented.
We report what is to our knowledge the first laboratory experiment that shows the use of a pyramid wavefront sensor to cophase and align segmented mirrors having three degrees of freedom per segment, i.e., piston, tip, and tilt. In the laboratory the iterative alignment procedure reached a wavefront residual error of about . The residual error was equally distributed between piston, tip, and tilt. These results demonstrate that the pyramid can successfully simultaneously sense the piston, tip, and tilt of a segmented mirror. This last feature makes this technique very attractive in phasing and aligning astronomical segmented telescopes such as extremely large telescopes currently under extensive studies.
We present the laboratory characterization and performance evaluation of the First Light Adaptive Optics (FLAO), the natural guide star adaptive optics system for the Large Binocular Telescope (LBT). The system uses an adaptive secondary mirror with 672 actuators and a pyramid wavefront sensor with adjustable sampling of the telescope pupil from 30×30 down to 7×7 subapertures. The system was fully assembled in the Arcetri Observatory laboratories and passed its acceptance test in December 2009. The performance measured at different star magnitudes during the acceptance test is shown to lie between the baseline and the goal specifications. In particular, FLAO obtained a 77% Strehl ratio (SR) in the bright end (8.5 magnitude star in the R band) using an H-band filter and correcting 495 modes with 30×30 subaperture sampling. In the faint end (16.4 magnitude), a 5% SR correcting 36 modes with 7×7 subapertures was measured. The seeing conditions for these tests were 0.8 arcsec (r0=0.14 m at 550 nm) and an average wind speed of 15 m/s. The results for other seeing conditions up to 1.5 arcsec are also presented. The system has been shipped to the LBT site in Arizona, and its commissioning started in March 2010.