Arjun Kumar

Arjun Kumar

Auto-generated profile, based on publicly available information

Arjun Kumar

Department of Computer Science, KAIST, Daejeon, South Korea

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2023
Verified
Conference Paper
Open access
JKJaeheon Kwak
Jaeheon Kwak
SLSunjae Lee
Sunjae Lee
DJDae R. Jeong
Dae R. Jeong
AKArjun Kumar
Arjun Kumar
DSDongjae Shin
Dongjae Shin
ISInsik Shin
Insik Shin

4 March 2026 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
AKArjun Kumar
Arjun Kumar
NWNoppanat Wadlom
Noppanat Wadlom
JKJaeheon Kwak
Jaeheon Kwak
SKSi-Hyuck Kang
Si-Hyuck Kang
ISInsik Shin
Insik Shin
Arrhythmia is a common cardiac condition that can precipitate severe complications without timely intervention. Among them, atrial fibrillation (AF) is the most common form. While continuous monitoring is essential for timely diagnosis, conventional approaches such as electrocardiogram (ECG) and wearable devices are constrained by their reliance on specialized medical expertise and patient discomfort from their contact nature. Existing contactless monitoring, primarily designed for healthy subjects, face significant challenges when analyzing reflections from AF patients due to disrupted spatial stability and temporal consistency caused by underlying irregular heart contractions. In this paper, we introduce mCardiacDx, a radar-driven contactless system that accurately analyzes these complex reflections and reconstructs heart pulse waveforms (HPWs) for AF monitoring and diagnosis. The key technical contributions of our work include a novel precise target localization (PTL) technique that accurately locates heart reflections despite spatial disruptions, an encoder-decoder model (HPR-Net) that effectively transforms these reflections into HPWs, addressing temporal inconsistencies, and a final analysis module for AF monitoring and diagnosis. Our evaluation on a dataset of 48 subjects (24 healthy, 24 with AF) in a seated, normal breathing, real-world setting shows that both mCardiacDx and the PTL technique significantly outperform the state-of-the-art approach in monitoring and diagnosing AF. Objective: To develop a contactless radar-driven system, mCardiacDx, that overcomes reflection disruption challenges in AF patients to accurately reconstruct interpretable heart pulse waveforms (HPWs) for monitoring and diagnosis.Methods and procedures: We introduce a PTL technique to locate heart reflections despite spatial disruptions, and an encoder-decoder model (HPR-Net) to robustly process reflections and reconstruct interpretable HPWs, addressing temporal inconsistencies. The HPWs are then processed by a final analysis module for AF monitoring and diagnosis. mCardiacDx is validated against a state-of-the-art approach (baseline) on a dataset of 48 subjects (24 healthy, 24 with AF) in a seated, normal breathing, real-world setting. This validation confirms the system’s robustness and generalizability to real-world seated scenarios variations in posture and environment.Results: mCardiacDx significantly outperforms the baseline in both monitoring and diagnosis. HPW fidelity (Dynamic time warping (DTW) score) for AF patients improves from 5.92 to 2.92. HR/RR interval median absolute percentage error (MedAPE) reduced (e.g., HR from 9.10 % to 2.94 %; RR interval from 8.42 % to 2.95 %). Our system achieves superior diagnostic performance with 0.93 accuracy, and 0.91 recall (sensitivity), significantly surpassing the baseline’s accuracy of 0.85 and recall of 0.75, while both maintain a specificity of 0.96.Conclusion: mCardiacDx is a robust, non-contact system for continuous cardiac care, addressing a critical gap in real-world AF monitoring and diagnosis.

17 September 2025 in IEEE Transactions on Sustainable Computing
Verified
Journal Article
Closed access
JKJaeheon Kwak
Jaeheon Kwak
SLSunjae Lee
Sunjae Lee
DJDae R. Jeong
Dae R. Jeong
AKArjun Kumar
Arjun Kumar
DSDongjae Shin
Dongjae Shin
ISInsik Shin
Insik Shin
Even with advances in single-cell batteries, mobile users still experience low battery anxiety. By analyzing 19,855 hours of user behavior, we propose MixMax, a heterogeneous battery system consisting of three complementary battery types tailored to minimizing low battery time. While the heterogeneous battery system offers an opportunity to simultaneously improve capacity and charging speed, one must face non-trivial challenges to design charge/discharge policies during runtime and determine the ratio of enclosed batteries. They are highly dependent on each other, which entails almost infinite candidates for the choice. MixMax simplifies this by reformulating the problem as an optimization problem, breaking it down into manageable sub-problems. However, MixMax still faces the challenge of catering to all users due to their diverse battery usage patterns. To address this, we introduce a customized MixMax that groups users based on their usage patterns and provides tailored battery solutions. In evaluating MixMax, we fabricate coin-cell batteries, develop a precise battery emulator using the fabricated batteries, and prototype MixMax on a real-world smartphone. Our evaluation shows that MixMax reduces low battery time by up to 24.6% without compromising capacity, volume, weight, or user behavior, and its customized version can further reduce it by up to 46.2%.