4 February 2015 in Nature Communications
Nanopores can probe the structure of biopolymers in solution; however, diffusion makes it difficult to study the same molecule for extended periods. Here we report devices that entropically trap single DNA molecules in a 6.2-femtolitre cage near a solid-state nanopore. We electrophoretically inject DNA molecules into the cage through the nanopore, pause for preset times and then drive the DNA back out through the nanopore. The saturating recapture time and high recapture probability after long pauses, their agreement with a convection–diffusion model and the observation of trapped DNA under fluorescence microscopy all confirm that the cage stably traps DNA. Meanwhile, the cages have 200 nm openings that make them permeable to small molecules, like the restriction endonuclease we use to sequence-specifically cut trapped DNA into fragments whose number and sizes are analysed upon exiting through the nanopore. Entropic cages thus serve as reactors for chemically modifying single DNA molecules.
20 December 2019 in Small
4 October 2018 in Scientific Reports
Accessible point-of-care technologies that can provide immunoassay and molecular modalities could dramatically enhance diagnostics, particularly for infectious disease control in low-resource settings. Solid-state nanopores are simple and durable sensors with low-energy instrumentation requirements. While nanopore sensors have demonstrated efficacy for nucleic acid targets, selective detection and quantification of target proteins from sample background has not been demonstrated. We present a simple approach for electronic detection and quantification of target proteins that combines novel biomolecular engineering methods, a portable reader device and disposable nanopore test strips. The target of interest can be varied by swapping the binding domain on our engineered detection reagent, which eficiently binds in the bulk-phase to the target and subsequently generates a unique signature when passing through the pore. We show modularity of the detection reagent for two HIV antibodies, TNFα and tetanus toxin as targets. A saliva swab-to-result is demonstrated for clinically relevant HIV antibody levels (0.4–20 mg/liter) in under 60 seconds. While other strip-like assays are qualitative, the presented method is quantitative and sets the stage for simultaneous immunoassay and molecular diagnostic functionality within a single portable platform.
19 January 2012 in The Journal of Physical Chemistry B