Xu Liu

Xu Liu

Auto-generated profile, based on publicly available information

Xu Liu

Ontera Inc., Santa Cruz, CA, 95060, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2015 in Nature Communications
Verified
Journal Article
Open access
PDF file
XLXu Liu
Xu Liu
MSMirna Mihovilovic Skanata
Mirna Mihovilovic Skanata
DSDerek Stein
Derek Stein
Nanopores can probe the structure of biopolymers in solution; however, diffusion makes it difficult to study the same molecule for extended periods. Here we report devices that entropically trap single DNA molecules in a 6.2-femtolitre cage near a solid-state nanopore. We electrophoretically inject DNA molecules into the cage through the nanopore, pause for preset times and then drive the DNA back out through the nanopore. The saturating recapture time and high recapture probability after long pauses, their agreement with a convection–diffusion model and the observation of trapped DNA under fluorescence microscopy all confirm that the cage stably traps DNA. Meanwhile, the cages have 200 nm openings that make them permeable to small molecules, like the restriction endonuclease we use to sequence-specifically cut trapped DNA into fragments whose number and sizes are analysed upon exiting through the nanopore. Entropic cages thus serve as reactors for chemically modifying single DNA molecules.

17 October 2018 in Small
Verified
Journal Article
Closed access
PDF file
YZYuning Zhang
Yuning Zhang
XLXu Liu
Xu Liu
YZYanan Zhao
Yanan Zhao
JYJen‐Kan Yu
Jen‐Kan Yu
WRWalter Reisner
Walter Reisner
WDWilliam B. Dunbar
William B. Dunbar

5 May 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TMTrevor J. Morin
Trevor J. Morin
TSTyler Shropshire
Tyler Shropshire
XLXu Liu
Xu Liu
KBKyle Briggs
Kyle Briggs
CHCindy Huynh
Cindy Huynh
WDWilliam B. Dunbar
William B. Dunbar
The promise of portable diagnostic devices relies on three basic requirements: comparable sensitivity to established platforms, inexpensive manufacturing and cost of operations, and the ability to survive rugged field conditions. Solid state nanopores can meet all these requirements, but to achieve high manufacturing yields at low costs, assays must be tolerant to fabrication imperfections and to nanopore enlargement during operation. This paper presents a model for molecular engineering techniques that meets these goals with the aim of detecting target sequences within DNA. In contrast to methods that require precise geometries, we demonstrate detection using a range of pore geometries. As a result, our assay model tolerates any pore-forming method and in-situ pore enlargement. Using peptide nucleic acid (PNA) probes modified for conjugation with synthetic bulk-adding molecules, pores ranging 15-50 nm in diameter are shown to detect individual PNA-bound DNA. Detection of the CFTRΔF508 gene mutation, a codon deletion responsible for ∼66% of all cystic fibrosis chromosomes, is demonstrated with a 26-36 nm pore size range by using a size-enhanced PNA probe. A mathematical framework for assessing the statistical significance of detection is also presented.

20 December 2019 in Small
Verified
Journal Article
Closed access
PDF file
XLXu Liu
Xu Liu
PZPhilip Zimny
Philip Zimny
YZYuning Zhang
Yuning Zhang
ARAnkit Rana
Ankit Rana
RNRoland Nagel
Roland Nagel
WDWilliam B. Dunbar
William B. Dunbar

4 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TMTrevor J. Morin
Trevor J. Morin
WMWilliam L. McKenna
William L. McKenna
TSTyler D. Shropshire
Tyler D. Shropshire
DWDustin A. Wride
Dustin A. Wride
JDJoshua D. Deschamps
Joshua D. Deschamps
WDWilliam B. Dunbar
William B. Dunbar
Accessible point-of-care technologies that can provide immunoassay and molecular modalities could dramatically enhance diagnostics, particularly for infectious disease control in low-resource settings. Solid-state nanopores are simple and durable sensors with low-energy instrumentation requirements. While nanopore sensors have demonstrated efficacy for nucleic acid targets, selective detection and quantification of target proteins from sample background has not been demonstrated. We present a simple approach for electronic detection and quantification of target proteins that combines novel biomolecular engineering methods, a portable reader device and disposable nanopore test strips. The target of interest can be varied by swapping the binding domain on our engineered detection reagent, which eficiently binds in the bulk-phase to the target and subsequently generates a unique signature when passing through the pore. We show modularity of the detection reagent for two HIV antibodies, TNFα and tetanus toxin as targets. A saliva swab-to-result is demonstrated for clinically relevant HIV antibody levels (0.4–20 mg/liter) in under 60 seconds. While other strip-like assays are qualitative, the presented method is quantitative and sets the stage for simultaneous immunoassay and molecular diagnostic functionality within a single portable platform.

19 January 2012 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
WYWenbo Yu
Wenbo Yu
ZWZhiqing Wu
Zhiqing Wu
HCHuibin Chen
Huibin Chen
XLXu Liu
Xu Liu
AMAlexander MacKerell
Alexander MacKerell
Zijing LinZijing Lin
Zijing Lin