1 May 2005 in Molecular Cell
1 October 2019 in Cell Reports
The type VI secretion system (T6SS) is crucial in interbacterial competition and is a virulence determinant of many Gram-negative bacteria. Several T6SS effectors are covalently fused to secreted T6SS structural components such as the VgrG spike for delivery into target cells. In Pseudomonas aeruginosa, the VgrG2b effector was previously proposed to mediate bacterial internalization into eukaryotic cells. In this work, we find that the VgrG2b C-terminal domain (VgrG2bC-ter) elicits toxicity in the bacterial periplasm, counteracted by a cognate immunity protein. We resolve the structure of VgrG2bC-ter and confirm it is a member of the zinc-metallopeptidase family of enzymes. We show that this effector causes membrane blebbing at midcell, which suggests a distinct type of T6SS-mediated growth inhibition through interference with cell division, mimicking the impact of β-lactam antibiotics. Our study introduces a further effector family to the T6SS arsenal and demonstrates that VgrG2b can target both prokaryotic and eukaryotic cells.
31 August 2016 in Acta Crystallographica Section D Structural Biology
The development of single-photon-counting detectors, such as the PILATUS, has been a major recent breakthrough in macromolecular crystallography, enabling noise-free detection and novel data-acquisition modes. The new EIGER detector features a pixel size of 75 × 75 µm, frame rates of up to 3000 Hz and a dead time as low as 3.8 µs. An EIGER 1M and EIGER 16M were tested on Swiss Light Source beamlines X10SA and X06SA for their application in macromolecular crystallography. The combination of fast frame rates and a very short dead time allows high-quality data acquisition in a shorter time. The ultrafine φ-slicing data-collection method is introduced and validated and its application in finding the optimal rotation angle, a suitable rotation speed and a sufficient X-ray dose are presented. An improvement of the data quality up to slicing at one tenth of the mosaicity has been observed, which is much finer than expected based on previous findings. The influence of key data-collection parameters on data quality is discussed.
1 September 2003 in The EMBO Journal
The 20S proteasome is a large multisubunit assembly that performs most of the intracellular non‐lysosomal proteolysis of eukaryotes. Substrates access the proteasome active sites, which are sequestered in the interior of the barrel‐shaped structure, through pores that are opened by binding of activator complexes. The crystal structure of yeast proteasome in complex with an 11S activator suggested that activation results from disordering of the proteasome gate residues. Here we report further analysis of this structure, which demonstrates that, in contrast to earlier models, the activated proteasome adopts an ordered 7‐fold symmetric pore conformation that is stabilized by interactions formed by a cluster of highly conserved proteasome residues (Tyr8, Asp9, Pro17 and Tyr26). One non‐canonical cluster, which appears to be mandated by the requirement that eukaryotic proteasomes also form an ordered closed conformation, explains all deviations from perfect conservation of these residues. We also demonstrate the importance of these conserved residues for proteolysis by an archaeal proteasome. Evolutionary considerations suggest that other activators might induce the same open proteasome conformation as seen with the 11S activator.
1 January 2012 in Biochimica et Biophysica Acta (BBA) - Molecular Cell Research
29 April 2019 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Hybrid photon counting (HPC) detectors have radically transformed basic research at synchrotron light sources since 2006. They excel at X-ray diffraction applications in the energy range from 2 to 100 keV. The main reasons for their superiority are the direct detection of individual photons and the accurate determination of scattering and diffraction intensities over an extremely high dynamic range. The detectors were first adopted in macromolecular crystallography where they revolutionized data collection. They were soon also used for small-angle scattering, coherent scattering, powder X-ray diffraction, spectroscopy and increasingly high-energy applications. Here, we will briefly survey the history of HPC detectors, explain their technology and then show in detail how improved detection has transformed a wide range of experimental techniques. We will end with an outlook to the future, which will probably see HPC technology find even broader use, for example, in electron microscopy and medical applications. This article is part of the theme issue ‘Fifty years of synchrotron science: achievements and opportunities’.