Maria Drangova

Maria Drangova

Auto-generated profile, based on publicly available information

Maria Drangova

Robarts Research Institute, Western University, London, Canada

Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2006 in JACC
Verified
Journal Article
Closed access
JWJames A. White
James A. White
RYRaymond Yee
Raymond Yee
XYXiaping Yuan
Xiaping Yuan
AKAndrew Krahn
Andrew Krahn
ASAllan Skanes
Allan Skanes
MDMaria Drangova
Maria Drangova

29 August 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
Cristian T BadeaCristian T Badea
Cristian T Badea
MDM Drangova
M Drangova
DHDavid Holdsworth
David Holdsworth
GJG A Johnson
G A Johnson
Small-animal imaging has a critical role in phenotyping, drug discovery and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review in vivo x-ray based small-animal imaging, with a focus on in vivo micro-computed tomography (micro-CT) and digital subtraction angiography (DSA). We present the principles, technologies, image quality parameters and types of applications. We show that both methods can be used not only to provide morphological, but also functional information, such as cardiac function estimation or perfusion. Compared to other modalities, x-ray based imaging is usually regarded as being able to provide higher throughput at lower cost and adequate resolution. The limitations are usually associated with the relatively poor contrast mechanisms and potential radiation damage due to ionizing radiation, although the use of contrast agents and careful design of studies can address these limitations. We hope that the information will effectively address how x-ray based imaging can be exploited for successful in vivo preclinical imaging.

1 July 2012 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
PGPeng Gao
Peng Gao
RYRaymond Yee
Raymond Yee
LGLorne Gula
Lorne Gula
AKAndrew D. Krahn
Andrew D. Krahn
ASAllan Skanes
Allan Skanes
JWJames A. White
James A. White
Background—: Scar signal quantification using late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) identifies patients at higher risk of future events, both in ischemic cardiomyopathy (ICM) and nonischemic dilated cardiomyopathy (DCM). However, the ability of scar signal burden to predict events in such patient groups at the time of referral for implantable cardioverter-defibrillator (ICD) has not been well explored. This study evaluates the predictive use of multiple scar quantification measures in ICM and DCM patients being referred for ICD. Methods and Results—: One hundred twenty-four consecutive patients referred for ICD therapy (59 with ICM and 65 with DCM) underwent a standardized LGE-CMR protocol with blinded, multithreshold scar signal quantification and, for those with ICM, peri-infarct signal quantification. Patients were followed prospectively for the primary combined outcome of appropriate ICD therapy, survived cardiac arrest, or sudden cardiac death. At a mean follow-up of 632 ± 262 days, 18 patients (15%) had suffered the primary outcome. Total scar was significantly higher among those suffering a primary outcome, a relationship maintained within each cardiomyopathy cohort ( P <0.01 for all comparisons). Total scar was the strongest independent predictor of the primary outcome and demonstrated a negative predictive value of 86%. In the ICM subcohort, peri-infarct signal showed only a nonsignificant trend toward elevation among those having a primary end point. Conclusions—: Myocardial scar quantification by LGE-CMR predicts arrhythmic events in patients being evaluated for ICD eligibility irrespective of cardiomyopathy etiology.

1 July 2009 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
YTY. Thakur
Y. Thakur
JBJ.S. Bax
J.S. Bax
DHD.W. Holdsworth
D.W. Holdsworth
MDM. Drangova
M. Drangova
A novel remote catheter navigation system has been developed to reduce physical stress and irradiation to the interventionalist during fluoroscopic X-ray guided catheter intervention. The unique teleoperated design of this system allows the interventionalist to apply conventional axial and radial motion, as used in current practice, to an input catheter placed in a radiation-safe location to control a second catheter placed inside the procedure room. A catheter sensor (used to measure motion of the input catheter) and a catheter manipulator (used to manipulate the second catheter) are both presented. Performance evaluation of the system was assessed by first conducting bench-top experiments to quantify accuracy and precision of both sensed and replicated motion, and then conducting two experiments to evaluate the latency from sensed to replicated motion. The first study consisted of replicating motions of prescribed motion trajectories, while the second study utilized eight operators to remotely navigate a catheter through a normal carotid model. The results show the system has the ability to sense and replicate motion to within 1 mm and 1deg in the axial and radial directions, respectively. Remote catheter manipulation was found to be operator dependent and occurred under 300 ms. Future applications of this technology are then presented.

22 April 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
PJPatricia M. Johnson
Patricia M. Johnson
MDMaria Drangova
Maria Drangova

16 October 2008 in Medical Physics
Verified
Journal Article
Closed access
PGP. V. Granton
P. V. Granton
SPS. I. Pollmann
S. I. Pollmann
NFN. L. Ford
N. L. Ford
MDM. Drangova
M. Drangova
DHDavid Holdsworth
David Holdsworth