3 November 2015 in International Journal of Colorectal Disease
1 January 2022 in Journal Of Neuroradiology
25 March 2021 in The Laryngoscope
3 February 2022 in Medeniyet Medical Journal
This study aims to develop neural networks to detect hormone secretion profiles in the pituitary adenomas based on T2 weighted magnetic resonance imaging (MRI) radiomics. This retrospective model-development study included a cohort of patients with pituitary adenomas (n=130) from January 2015 to January 2020 in one tertiary center. The mean age was 46.49±13.69 years, and 76/130 (58.46%) were women. Three observers segmented lesions on coronal T2 weighted MRI, and an interrater agreement was evaluated using the Dice coefficient. Predictors were determined as radiomics features (n=851). Feature selection was based on intraclass correlation coefficient, coefficient variance, variance inflation factor, and LASSO regression analysis. Outcomes were identified as 7 hormone secretion profiles [nonfunctioning pituitary adenoma, growth hormone-secreting adenomas, prolactinomas, adrenocorticotropic hormone-secreting adenomas, pluri-hormonal secreting adenomas (PHA), follicle-stimulating hormone and luteinizing hormone-secreting adenomas, and thyroid-stimulating hormone adenomas]. A multivariable diagnostic prediction model was developed with artificial neural networks (ANN) for 7 outcomes. ANN performance was presented as an area under the receiver operating characteristic curve (AUC) and accepted as successful if the AUC was >0.85 and p-value was <0.01. The performance of the ANN distinguishing prolactinomas from other adenomas was validated (AUC=0.95, p<0.001, sensitivity: 91%, and specificity: 98%). The model distinguishing PHA had the lowest AUC (AUC=0.74 and p0.85 and p values were <0.001. This study was successful in training neural networks that could differentiate the hormone secretion profile of pituitary adenomas.
1 January 2021 in The Journal of International Advanced Otology
OBJECTIVES: This study used the data from patients with congenital sensorineural hearing loss (CSNHL) and those with normal hearing to measure and compare the length of the cochlea with high-resolution computed tomography (HRCT). MATERIALS and METHODS: HRCT images of patients who were diagnosed with CSNHL and were candidates for cochlear implantation were evaluated retrospectively. Sixty-three ears of 33 patients were included in the study. The control group comprised 66 ears of 33 individuals. The measurements were conducted by an experienced radiologist, using three-dimensional curved multiplanar reconstruction. All the measurements were performed thrice, and the average was calculated. RESULTS: The data were distributed normally. The lengths of the cochlear components for the CSNHL and control groups were as follows: basal turn 21.66±1.01 (21.30-22.02) and 22.57±0.68 (22.32-22.81) mm, middle turn 11.58±0.69 (11.34-11.83) and 12.39±0.46 (12.23-12.56) mm, and apical turn 6.45±0.92 (6.12-6.77) and 7.12±0.65 (6.89-7.35) mm, respectively. The mean cochlear lateral wall (LW) length was significantly shorter in the CSNHL patients [39.71±1.32 (39.25-40.18) mm] than in the controls [42.09±1.17 (41.67-42.51) mm], (p<0.001). The intra-rater reliability was 0.878 (confidence interval 95%: 0.841-0.908 p<0.001). The cut-off value was 40.81 mm (sensitivity: 0.91, specificity: 0.94, and accuracy: 0.90). CONCLUSION: There were microanatomic dissimilarities between the length of the cochlea in subjects from the CSNHL group and those from the control group. Cite this article as: Eser MB, Atalay B, Kalcıoğlu MT. A Preliminary Data: Is Cochlear Length Related to Congenital Sensorineural Hearing Loss? J Int Adv Otol 2021; 17(1): 1-8
30 September 2021 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Prior studies have evaluated cochlear length using CT to select the most suitable cochlear implants and obtain patient-specific anatomy. This study aimed to test the accuracy and reliability of cochlear lateral wall length measurements using 3D MR imaging. MATERIALS AND METHODS: Two observers measured the cochlear lateral wall length of 35 patients (21 men) with postlingual hearing loss using CT and MR imaging. The intraclass correlation coefficient (with 95% confidence intervals) was used to evaluate intraobserver and interobserver reliability for the 3D cochlear measurements. RESULTS: The mean age of the participants was 39.85 (SD, 16.60) years. Observer 1 measured the mean lateral wall length as 41.52 (SD, 2.25) mm on CT and 41.44 (SD, 2.18) mm on MR imaging, with a mean difference of 0.08 mm (95% CI, −0.11 to 0.27 mm), while observer 2 measured the mean lateral wall length as 41.74 (SD, 2.69) mm on CT and 42.34 (SD, 2.53) mm on MR imaging, with a mean difference of −0.59 mm (95% CI, −1.00 to −0.20 mm). An intraclass correlation coefficient value of 0.90 (95% CI, 0.84−0.94) for CT and 0.69 (95% CI, 0.46−0.82) for MR imaging was obtained for the interobserver reliability for the full-turn cochlear lateral wall length. CONCLUSIONS: CT-based 3D cochlear measurements show excellent intraobserver and interobserver reliability, while MR imaging−based lateral wall length measurements have good-to-excellent intraobserver reliability and moderate interobserver reliability. These results corroborate the use of CT for 3D cochlear measurements as a reference method and demonstrate MR imaging to be an alternative acquisition technique with comparably reliable results.