Ye Huang

Ye Huang

Auto-generated profile, based on publicly available information

Ye Huang

Sanhang Institute for Brain Science and Technology (SiBST), School of Life Science and Technology, Northwestern Polytechnical University

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2024 in Heliyon
Verified
Journal Article
Open access
YHYe Huang
Ye Huang
LYLongfeng Yu
Longfeng Yu
FZFeifan Zhang
Feifan Zhang
Percutaneous needle insertion is a minimally invasive surgery with broad medical application prospects, such as biopsy and brachytherapy. However, the currently adopted rigid needles have limitations, as they cannot bypass obstacles or correct puncture deviations and can only travel along a straight path. Bevel-tip flexible needles are increasingly being adopted to address these issues, owing to their needle body's ease of deformation and bending. Successful puncture of flexible needles relies on accurate models and path planning, ensuring the needle reaches the target while avoiding vital tissues. This review investigates puncture models and path-planning algorithms by reviewing recent literature, focusing on the path-planning part. According to the literature, puncture models can be divided into three types: mechanical, finite element method (FEM), and kinematic models, while path-planning algorithms are categorized and discussed following the division used for mobile robots, which differs from the conventional approach for flexible needles-an innovation in this review. This review systematically summarizes the following categories: graph theory search, sampling-based, intelligent search, local obstacle avoidance, and other algorithms, including their implementation, advantages, and disadvantages, to further explore the potential to overcome obstacles in path planning for minimally invasive puncture needles. Finally, this study proposes future development trends in path-planning algorithms, providing possible directions for subsequent research for bevel-tipped flexible needles. This research aims to provide a resource for researchers to quickly learn about common path-planning algorithms, their backgrounds, and puncture models.

4 March 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YHYe Huang
Ye Huang
FZFeifan Zhang
Feifan Zhang
Flexible-needle percutaneous puncture is a widely used medical technique in clinical practice and is known for its advantages of minimal patient, fast recovery, and ease of operation. However, ensuring accuracy and avoiding obstacles during the puncture process are challenging because of the non-holonomic motion of the needle tip and the presence of obstacles and sensitive organs. To address this issue, this study proposed a novel path planning algorithm for robot-assisted flexible needle punctures. The algorithm is based on a bidirectional rapidly exploring random tree and incorporates target-oriented and rapid-search strategies. This provides a feasible approach for the clinical application of flexible-needle puncture, outperforming commonly used algorithms in terms of computational speed, path representation, and search capabilities. Additionally, this study applies a duty-cycling control strategy for a flexible needle, enabling proportional control of the curvature of the needle trajectory during soft tissue insertion. The effectiveness of the proposed path planning algorithm was validated through experiments using a duty-cycling strategy, and an experimental error within 4 mm was deemed adequate for most clinical needle-insertion applications.

10 November 2026 in Journal of Neural Engineering
Verified
Journal Article
Closed access
YHYe Huang
Ye Huang
JCJiaxu Cao
Jiaxu Cao
XWXuanqi Wang
Xuanqi Wang
XYXiaoli You
Xiaoli You
RBRuiyu Bai
Ruiyu Bai
Bowen JiBowen Ji
Bowen Ji
Objective . Wireless implantable neurologgers are emerging as miniature autonomous systems for long-term, untethered neural recording in animal studies. However, their development remains constrained by critical engineering bottlenecks, including neural recording, power supply, and data transmission. Approach. This review systematically summarizes representative commercial neurologgers and state-of-the-art research advances. Recent progress in three key engineering areas is then reviewed, covering high-performance electrode technologies, efficient wireless power transfer strategies, and advanced communication technologies. Main results. The critical trade-offs among energy efficiency, bandwidth, transmission distance, and system complexity are identified. Furthermore, the influence of diverse application environments on system-level design and the practical implementation of neurologgers is analyzed from a new perspective. Significance. This review discusses the remaining technical challenges and future research directions, providing guidance for the development of fully autonomous wireless implantable neural recording systems for animal studies.