M. S. Murshitha Shajahan

M. S. Murshitha Shajahan

Auto-generated profile, based on publicly available information

M. S. Murshitha Shajahan

B. S. Abdur Rahman Crescent Institute of Science and Technology

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
PBPriyanka Bhadra
Priyanka Bhadra
MSMohammed S. Shajahan
Mohammed S. Shajahan
PPParesh N Patel
Paresh N Patel
EBEnakshi Bhattacharya
Enakshi Bhattacharya
ACAnju Chadha
Anju Chadha
Praveen SekharPraveen Sekhar
Praveen Sekhar
The article reports a proof of concept validation of bacterial detection using Siderophores. Desferrioxamine B (DesfB) was used as the Siderophore to capture Escherichia coli on gold coated microcantilever surface. Self-assembled monolayer based gold thiol chemistry was used for surface functionalization of the Siderophore on top surface of the microcantilever. The bacterial attachment to the siderophore was observed through Fourier Transform Infrared Spectroscopy (FTIR) and Fluorescence Microscopy. The DesfB coated surface allows only the live bacterial cells to be attached and it is evident through the FTIR band formation. In a mixture of live and dead E. coli cells, the Fluorescence Microscope image indicates green emission from live cells and a core-shell structure formation upon progress of time. For a sample dilution of 10−1, the mass change of live E. coli bonded to Siderophores is four times higher than that of dead cells and 12 times higher to that of negative control on microcantilevers. Therefore this study should be considered as a foundation to build a miniaturized biosensing platform to distinguish between bacterial or viral infections in real time. The proposed platform could differentiate between bacterial and viral infections thus rendering it as Point of Care (PoC) diagnostic tool aiding Internet of Things (IoT) applications.

1 September 2018 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
MSM.S. Murshitha Shajahan
M.S. Murshitha Shajahan
DJD. Najumnissa Jamal
D. Najumnissa Jamal
VAV. Aparna
V. Aparna
MKM.K.A. Ahamed Khan
M.K.A. Ahamed Khan

17 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
KSKarthikeyan Sundaram
Karthikeyan Sundaram
MSMurshitha Shajahan
Murshitha Shajahan
KRKarthikha R
Karthikha R
: Maintaining a balance between scheduled and actual demand is critical for grid stability and economic efficiency in deregulated electricity markets, particularly under regulatory frameworks such as India’s Deviation Settlement Mechanism (DSM) that imposes nonlinear and frequency-sensitive penalties on deviations. Although artificial intelligence models have significantly enhanced short-term load forecasting (STLF) accuracy, most existing approaches focus on minimizing statistical error metrics like Mean Absolute Error (MAE) and Root Mean Square Error (RMSE), without explicitly addressing economic penalty exposure, resulting in a gap between predictive accuracy and regulatory cost optimization. This research proposes a DSM-aware analytical framework for short-horizon (six-block) demand estimation based on four months of half-hourly operational data which has 5,472 number of time blocks. A structured preprocessing pipeline and domain-driven feature engineering methodology are used to develop 40 features capturing temporal dependencies, cyclic behavior, volatility, and seasonal patterns. Four benchmark models—LSTM, GRU, XGBoost, and Transformer—are trained using a sliding window technique and evaluated with statistical metrics and a DSM cost formulation based on deviation-weighted penalty rates. Results demonstrate that XGBoost obtains the highest statistical accuracy (MAE ≈ 110 MW, RMSE ≈ 192 MW), while LSTM and GRU performs moderate (MAE ≈ 224–249 MW), and Transformer exhibits comparable MAE (~248 MW) but larger RMSE (~347 MW), indicating greater variance. Economic evaluation shows that Transformer achieves the lowest DSM cost (₹6.65 million), outperforming LSTM (₹7.06 million), XGBoost (₹7.19 million), and GRU (₹7.38 million). Residual analysis shows that while XGBoost reduces average error, it produces occasional high-magnitude deviations, whereas Transformer suppresses extreme deviation spikes effectively that influence DSM penalties. These findings emphasize that reducing statistical error does not ensure economic optimality, emphasizing the necessity of tail-risk-aware forecasting and encouraging the development of cost-sensitive, DSM-integrated predictive models for real-world grid operations.