Fentanyl is a potent, effective analgesic and narcotic drug widely used for anesthesia and chronic pain control. In this study, a simple electrochemical method for the detection of fentanyl in aqueous solutions was developed. The modification of a screen-printed carbon electrode (SPCE) was performed by casting a metal–organic framework (MOF) on its surface. The characterization of the zinc-based MOF (Zn(II)-MOF) modifier was investigated via scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier transform infrared (FT-IR) and X-ray diffraction (XRD) techniques. The differential pulse voltammetry (DPV) technique was used for evaluating the fentanyl electrochemical behavior on the electrodes. The optimum experimental conditions were investigated by examining the effects of the scan rate and pH on the cyclic voltammetry (CV) and DPV responses, respectively. The results showed that fentanyl has an irreversible behavior at the potential of 0.9 V and its current increases in the presence of MOF. The application of the presented electrode with the DPV method showed a detection limit of 0.3 μM in the concentration range of 1–100 μM (linear range) for the fentanyl in an aqueous solution. The modified electrode was successfully used to determine the low levels of fentanyl in urine and plasma as the real samples.
A dispersive solid-phase microextraction method based on magnetic carbon nano-onions (MCNOs) was developed for the extraction and preconcentration of some pesticides from water and vegetable samples. For more cleanup and preconcentration, a dispersive liquid–liquid microextraction (DLLME) method was employed after performing the first step. In this method, firstly, MCNOs were prepared and then used for adsorption of the analytes from the sample solution. After that, the adsorbed analytes were eluted with an appropriate water-miscible organic solvent and used as a dispersive solvent in the following DLLME procedure. The extracted analytes were quantified by gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) mode. Various factors affecting the method efficiency such as sorbent weight, salt effect, pH, temperature, and type and volume of eluent and extraction solvent were optimized. This method showed wide linear ranges with a coefficient of determination ≥ 0.994, and low limits of detection (0.001–0.005 ng mL−1) and quantification (0.003–0.019 ng mL−1) under optimal conditions. Also, a good precision (relative standard deviation ≤ 8.6%) for five replicates and a satisfactory accuracy (mean relative recoveries between 82 and 99%) were obtained. It can be considered as an efficient and environment friendly method for the extraction of analytes from vegetable and fruit juices and water samples.