John Joseph Graham

John Joseph Graham

Auto-generated profile, based on publicly available information

John Joseph Graham

Terrence Donnelly Heart Centre, St Michaels Hospital Toronto Ontario Canada

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2010 in The American Journal of Cardiology
Verified
Journal Article
Closed access
TLTony C. Lee
Tony C. Lee
SGShaun G. Goodman
Shaun G. Goodman
RYRaymond T. Yan
Raymond T. Yan
FGFrançois Grondin
François Grondin
RWRobert C. Welsh
Robert C. Welsh
AYAndrew T Yan
Andrew T Yan

28 September 2009 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
Kim A. ConnellyKim A. Connelly
Kim A. Connelly
JDJay Detsky
Jay Detsky
JGJohn J. Graham
John J. Graham
GPGideon Paul
Gideon Paul
RVRam Vijayaragavan
Ram Vijayaragavan
GWGraham A. Wright
Graham A. Wright
Purpose To determine the accuracy of multicontrast late enhancement imaging (MCLE) in the assessment of myocardial viability and wall motion compared to the conventional wall motion and viability cardiac magnetic resonance imaging (MRI) pulse sequences. Materials and Methods Forty-one patients with suspected myocardial infarction were studied. Patients underwent assessment of cardiac function with cine steady-state free-precession (SSFP), followed by late gadolinium enhancement (LGE) imaging using inversion recovery gradient echo scanning (IR-GRE) sequence and MCLE. MCLE was compared to cine SSFP in the assessment of wall motion, ejection fraction (EF), left ventricular (LV) mass, LV end-diastolic volume (EDV), and to IR-GRE for measuring infarct size. Results MCLE, IR-GRE, and SSFP imaging demonstrated excellent agreement in the assessment of EF, LV infarct size, and LV mass (r > 0.95, P < 0.001 for all measures), as well as in the assessment of wall motion (κ statistic 0.75). Conclusion MCLE provided coregistered images for the assessment of viability and wall motion without loss of accuracy in the assessment of quantitative cardiac parameters. MCLE provides accurate quantitative cardiac assessment with reduced scan times compared to the conventional sequences and thus may be used as an alternative to conventional cine SSFP and IR-GRE imaging. J. Magn. Reson. Imaging 2009;30:771–777.

25 January 2022 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
JGJohn J. Graham
John J. Graham
ABAkshay Bagai
Akshay Bagai
HWHarindra Wijeysundera
Harindra Wijeysundera
GWGiora Weisz
Giora Weisz
SRStéphane Rinfret
Stéphane Rinfret
CBChristopher E. Buller
Christopher E. Buller

23 April 2024 in Journal of the Society for Cardiovascular Angiography & Interventions
Verified
Journal Article
Open access
MMMelissa Y.Y. Moey
Melissa Y.Y. Moey
VPVikram Prabhudesai
Vikram Prabhudesai
EGElisa Greco
Elisa Greco
JGJohn J. Graham
John J. Graham
Subclavian artery pseudoaneurysms are rare and associated with high morbidity and mortality. Alternative approaches to open surgical repair can include endovascular repair or ultrasound-guided thrombin injection. Here, we describe a safe and novel technique of closure of a subclavian artery pseudoaneurysm with Angio-Seal that was unresponsive to thrombin injection and in a difficult location for open repair.

28 April 2021 in Current Opinion in Cardiology
Verified
Journal Article
Closed access
LBLucas Burke
Lucas Burke
JGJohn Joseph Graham
John Joseph Graham
Purpose of review: Coronary artery calcification (CAC) predisposes to suboptimal revascularization outcomes after percutaneous coronary intervention (PCI). Despite the availability of several plaque modification devices, their rates of use remain low despite the prevalence of CAC encountered in clinical practice. It is important to understand how each device can be utilized in clinical practice in order to improve outcomes after PCI. Recent findings: This article summarizes the most recent clinical evidence for each plaque modification device. Although rotational atherectomy is the most frequently used device for plaque modification, the use of orbital atherectomy (OA) has been increasing. Balloon-based strategies including recent studies evaluating a novel intravascular lithotripsy balloon have shed light on the benefits of nonablative devices in modifying CAC during PCI. Summary: CAC poses significant technical challenges in achieving optimal stent results. Several intracoronary plaque modification devices are currently available and understanding the technical aspects, indications and contraindications to the use of each device is essential. Although rotational and OA are most commonly used, laser atherectomy and balloon-based devices may offer an advantage in certain lesion subsets.

3 December 2024 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
DSDinesh Selvakumar
Dinesh Selvakumar
JGJohn J. Graham
John J. Graham
CBChristopher E. Buller
Christopher E. Buller
ABAkshay Bagai
Akshay Bagai