Timon H. Geurkink

Timon H. Geurkink

Auto-generated profile, based on publicly available information

Timon H. Geurkink

Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2023 in International Journal of Health Policy and Management
Verified
Journal Article
Open access
PDF file
LHLotje A. Hoogervorst
Lotje A. Hoogervorst
TGTimon H. Geurkink
Timon H. Geurkink
ALAnne Lübbeke
Anne Lübbeke
SBSergio Buccheri
Sergio Buccheri
JSJan Schoones
Jan Schoones
PMPerla J. Marang-Van de Mheen
Perla J. Marang-Van de Mheen
Background: The European Union Medical Device Regulation (MDR) requires manufacturers to undertake post-market clinical follow-up (PMCF) to assess the safety and performance of their devices following approval and Conformité Européenne (CE) marking. The quality and reliability of device registries for this Regulation have not been reported. As part of the Coordinating Research and Evidence for Medical Devices (CORE-MD) project, we identified and reviewed European cardiovascular and orthopaedic registries to assess their structures, methods, and suitability as data sources for regulatory purposes. Methods: Regional, national and multi-country European cardiovascular (coronary stents and valve repair/replacement) and orthopaedic (hip/knee prostheses) registries were identified using a systematic literature search. Annual reports, peer-reviewed publications, and websites were reviewed to extract publicly available information for 33 items related to structure and methodology in six domains and also for reported outcomes. Results: Of the 20 cardiovascular and 26 orthopaedic registries fulfilling eligibility criteria, a median of 33% (IQR: 14%-71%) items for cardiovascular and 60% (IQR: 28%-100%) items for orthopaedic registries were reported, with large variation across domains. For instance, no cardiovascular and 16 (62%) orthopaedic registries reported patient/ procedure-level completeness. No cardiovascular and 5 (19%) orthopaedic registries reported outlier performances of devices, but each with a different outlier definition. There was large heterogeneity in reporting on items, outcomes, definitions of outcomes, and follow-up durations. Conclusion: European cardiovascular and orthopaedic device registries could improve their potential as data sources for regulatory purposes by reaching consensus on standardised reporting of structural and methodological characteristics to judge the quality of the evidence as well as outcomes.

17 July 2019 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
KWKoen Willemsen
Koen Willemsen
TBThomas D. Berendes
Thomas D. Berendes
TGTimon Geurkink
Timon Geurkink
RBRonald L.A.W. Bleys
Ronald L.A.W. Bleys
MLMarius A. Leeflang
Marius A. Leeflang
BWBart C.H. van der Wal
Bart C.H. van der Wal
Background: Anterior glenohumeral instability with >20% glenoid bone loss is a disorder that can be treated with the Latarjet stabilizing procedure; however, complications are common. The purposes of this study were to (1) evaluate the effect of an anatomic-specific titanium implant produced by 3-dimensional (3D) printing as a treatment option for recurrent shoulder instability with substantial glenoid bone loss and (2) compare the use of that implant with the Latarjet procedure. Methods: Ten fresh-frozen cadaveric shoulders (mean age at the time of death, 78 years) were tested in a biomechanical setup with the humerus in 30° of abduction and in neutral rotation. The shoulders were tested under 5 different conditions: (1) normal situation, (2) creation of an anterior glenoid defect, (3) implantation of an anatomic-specific titanium implant produced by 3D printing, and the Latarjet procedure (4) with and (5) without 10 N of load attached to the conjoined tendon. In each condition, the humerus was translated 10 mm anteriorly relative to the glenoid, and the maximum peak translational force that was necessary for this translation was measured. Results: After creation of the glenoid defect, the mean translational peak force decreased by 30% ± 6% compared with that for the normal shoulder. After restoration of the original glenoid anatomy, the translational force needed to dislocate the humeral head from the glenoid significantly increased compared with that in the defect condition—to 119% ± 16% of normal (p < 0.01) with the 3D-printed anatomic-specific implant and to 121% ± 48% of normal (p < 0.01) following the Latarjet procedure. No significant differences in mean translational force were found between the anatomic-specific implant and the Latarjet procedure (p = 0.72). Conclusions: The mean translational peak force needed to dislocate the humerus 10 mm anteriorly on the glenoid was higher after glenoid restoration with the 3D-printed anatomic-specific implant compared with when the glenoid had a 20% surface defect but also compared with when the glenoid was intact. No differences in mean translational peak force were found between the 3D-printed anatomic-specific glenoid implant and the Latarjet procedure, although there was less variability in the 3D-implant condition. Clinical Relevance: Novel 3D-printing technology could provide a reliable patient-specific alternative to solve problems related to traditional treatment methods for shoulder instability.

15 October 2022 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Open access
TGTimon H. Geurkink
Timon H. Geurkink
HGHamez Gacaferi
Hamez Gacaferi
PMPerla J. Marang-Van de Mheen
Perla J. Marang-Van de Mheen
JSJan Schoones
Jan Schoones
JGJurriaan H. de Groot
Jurriaan H. de Groot
RNRob G.H.H. Nelissen
Rob G.H.H. Nelissen
Scapular winging is a rare condition of the shoulder girdle that presents challenging treatment decisions for clinicians. To inform clinical practice, clinicians need guidance on what the best treatment decision is for their patients, and such recommendations should be based on the total evidence available. Therefore, the purpose of this review was to systematically review the evidence regarding nonsurgical management and tendon transfer surgery of patients with neurologic scapular winging due to serratus anterior (SA) or trapezius (TP) palsy. PubMed, Embase, Web of Science, Cochrane Library, Emcare, and Academic Search Premier were searched up to April 5, 2022, for studies reporting on clinical outcomes after nonsurgical management and tendon transfer surgery of scapular winging due to weakness of the SA or TP muscle. The Integrated quality Criteria for Review Of Multiple Study (ICROMS) tool was used to classify the quality of the studies. Primary outcomes were the fraction of patients with spontaneous recovery after nonsurgical management and improvement in shoulder function, pain scores, and shoulder scores after tendon transfer surgery. Data were pooled if data on the same outcome were available for at least 3 studies, using random-effects meta-analysis. Twenty-three (10 moderate-quality [MQ] and 13 low-quality) studies were included. Six studies (3 MQ; 234 shoulders) reported on outcomes after nonsurgical management of SA palsy, whereas 12 (6 MQ; 221 shoulders) and 6 studies (1 MQ; 80 shoulders) evaluated the outcomes of tendon transfer for SA or TP palsy (1 study addressed both). Spontaneous recovery of scapular winging with nonsurgical management varied between 21% and 78% across studies after a median follow-up of 72 months. For surgical management of SA palsy, pooling data in a meta-analysis showed that patients on average improved by 47° (95% confidence interval [CI]: 34-61, P ≤ .001) in active forward flexion, had lower visual analog scale scores for pain (mean difference [MD]: -3.0, 95% CI: -4.9 to -1.0, P = .003), and had substantial improvements in American Shoulder and Elbow Surgeons (MD: 24, 95% CI: 9-39, P = .002) and Constant scores (MD: 45, 95% CI: 39-51, P ≤ .001). Patients with TP palsy on average improved by 36° (95% CI: 21-51, P ≤ .001) in active forward flexion after tendon transfer. Statistical pooling was not possible for other outcome measures as insufficient data were available. A substantial part of nonsurgically managed patients with scapular winging seem to have persistent complaints, which should be part of the information provided to patients. Data pooling demonstrated significant improvements in shoulder function, pain scores, and shoulder scores after tendon transfer surgery, but higher quality evidence is needed to allow for more robust recommendations and guide clinical decision-making on when to perform such functional surgery.

29 May 2023 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Open access
TGTimon H. Geurkink
Timon H. Geurkink
COCeleste L. Overbeek
Celeste L. Overbeek
PMPerla J. Marang-Van de Mheen
Perla J. Marang-Van de Mheen
JNJochem Nagels
Jochem Nagels
RNRob G.H.H. Nelissen
Rob G.H.H. Nelissen
JGJurriaan H. de Groot
Jurriaan H. de Groot
This study aimed to quantify the extent to which age was associated with joint position sense (JPS) of the asymptomatic shoulder as measured by joint position reproduction (JPR) tasks and assess the reproducibility of these tasks. 120 Asymptomatic participants aged 18-70 years each performed 10 JPR-tasks. Both contralateral and ipsilateral JPR-tasks were evaluated on accuracy of JPR under active- and passive conditions at two levels within the shoulder forward flexion trajectory. Each task was performed three times. In a subgroup of 40 participants, the reproducibility of JPR-tasks was assessed one week after initial measurement. Reproducibility of JPR-tasks was evaluated by both reliability (intra-class correlation coefficients (ICC's)) and agreement (standard error of measurement (SEM)) measures. Age was not associated with increased JPR-errors for any of the contralateral or ipsilateral JPR-tasks. ICC's ranged between 0.63 and 0.80 for contralateral JPR-tasks, and from 0.32 to 0.48 for ipsilateral tasks, except for one ipsilateral task where the reliability was similar to contralateral tasks (0.79). The SEM was comparable and small for all JPR-tasks, ranging between 1.1 and 2.1. No age-related decline in JPS of the asymptomatic shoulder was found, and good agreement between test and re-test measurements for all JPR-tasks as indicated by the small SEM.

21 April 2024 in JSES International
Verified
Journal Article
Open access
TGTimon H. Geurkink
Timon H. Geurkink
PMPerla J. Marang-Van de Mheen
Perla J. Marang-Van de Mheen
TRTim Robbers
Tim Robbers
JNJochem Nagels
Jochem Nagels
RNRob G.H.H. Nelissen
Rob G.H.H. Nelissen
A pectoralis major (PM) transfer is a viable treatment option for patients with scapular winging due to long thoracic nerve (LTN) palsy not responding to nonsurgical management. However, the long-term outcomes remain unknown. Therefore, the purpose of this study was to evaluate the long-term outcome of shoulder function (ie, minimum follow-up of 10 years) and quality-of-life (QoL) of patients treated for scapular winging due to LTN palsy with a PM transfer. This observational cohort study included 15 patients (16 shoulders) who underwent PM transfer, using a tendoachilles allograft, between 1995 and 2012. Shoulder forward flexion and abduction were analyzed preoperatively, 1 year after surgery and at the final follow-up. SF-36 component scores (physical component summary (PCS) and mental component summary (MCS)) were used to evaluate the QoL. Shoulder forward flexion and abduction measured in degrees improved from 86 (SD 14.5) and 82 (SD 33.8) preoperatively to 140 (SD 27.3) and 138 (31.3) at 1 year postoperatively. After a median follow-up of 17 years, mean shoulder functions were slightly lower than at 1 year postoperatively, but still better than preoperative function, ie, forward flexion 121 (SD 41.9) and abduction 122 (SD 44.5). The mean PCS score at the final follow-up was 41.9 (SD 9.7), and the mean MCS score was 49.9 (SD 12.5). Better shoulder function at the final follow-up was significantly associated with higher QoL in terms of PCS scores (P = .023), but not MCS scores (P = .287). The results of the present study indicate that PM transfer augmented with an achilles tendon allograft for scapular winging due to LTN palsy leads to functional improvements that persist in long term. These functional improvements likely translate to better QoL based on their association.

13 August 2023 in International Journal of Health Policy and Management
Verified
Journal Article
Open access
PDF file
TGTimon H. Geurkink
Timon H. Geurkink
PMPerla J. Marang-Van de Mheen
Perla J. Marang-Van de Mheen
JNJochem Nagels
Jochem Nagels
RPRudolf W. Poolman
Rudolf W. Poolman
RNRob G.H.H. Nelissen
Rob G.H.H. Nelissen
LBLeti van Bodegom-Vos
Leti van Bodegom-Vos
Background: Withdrawal of reimbursement for low-value care through a policy change, ie, active disinvestment, is considered a potentially effective de-implementation strategy. However, previous studies have shown conflicting results and the mechanism through which active disinvestment may be effective is unclear. This study explored how the active disinvestment initiative regarding subacromial decompression (SAD) surgery for subacromial pain syndrome (SAPS) in the Netherlands influenced clinical decision-making around surgery, including the perspectives of orthopedic surgeons and hospital sales managers. Methods: We performed 20 semi-structured interviews from November 2020 to October 2021 with ten hospital sales managers and ten orthopedic surgeons from twelve hospitals across the Netherlands as relevant stakeholders in the active disinvestment process. The interviews were video-recorded and transcribed verbatim. Inductive thematic analysis was used to analyse interview transcripts independently by two authors and discrepancies were resolved through discussion. Results: Two overarching themes were identified that negatively influenced the effect of the active disinvestment initiative for SAPS. The first theme was that the active disinvestment represented a "Too small piece of the pie" indicating little financial consequences for the hospital as it was merely used in negotiations with healthcare insurers to reduce costs, required a disproportionate amount of effort from hospital staff given the small saving-potential, and was not clearly defined nor enforced in the overall healthcare insurer agreements. The second theme was "They [healthcare insurer] got it wrong," as the evidence and guidelines had been incorrectly interpreted, the active disinvestment was at odds with clinician experiences and beliefs and was perceived as a reduction in their professional autonomy. Conclusion: The two overarching themes and their underlying factors highlight the complexity for active disinvestment initiatives to be effective. Future de-implementation initiatives including active disinvestment should engage relevant stakeholders at an early stage to incorporate their different perspectives, gain support and increase the probability of success.