Lavinia Barducci

Lavinia Barducci

Auto-generated profile, based on publicly available information

Lavinia Barducci

STORM Lab UK, University of Leeds, Leeds LS2 9JT, U.K

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2019 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
GPGiovanni Pittiglio
Giovanni Pittiglio
LBLavinia Barducci
Lavinia Barducci
JMJames W. Martin
James W. Martin
JNJoseph C. Norton
Joseph C. Norton
Carlo Alberto AvizzanoCarlo Alberto Avizzano
Carlo Alberto Avizzano
PVPietro Valdastri
Pietro Valdastri
The present letter investigates a novel control approach for magnetically driven soft-tethered capsules for colonoscopy-a potentially painless approach for colon inspection. The focus of this work is on a class of devices composed of a magnetic capsule endoscope actuated by a single external permanent magnet. Actuation is achieved by manipulating the external magnet with a serial manipulator, which in turn produces forces and torques on the internal magnetic capsule. We propose a control strategy which, counteracting gravity, achieves levitation of the capsule. This technique, based on a nonlinear backstepping approach, is able to limit contact with the colon walls, reducing friction, avoiding contact with internal folds, and facilitating the inspection of nonplanar cavities. The approach is validated on an experimental setup, which embodies a general scenario faced in colonoscopy. The experiments show that we can attain 19.5% of contact with the colon wall, compared to the almost 100% of previously proposed approaches. Moreover, we show that the control can be used to navigate the capsule through a more realistic environment-a colon phantom-with reasonable completion time.

15 July 2019 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
LBLavinia Barducci
Lavinia Barducci
GPGiovanni Pittiglio
Giovanni Pittiglio
JNJoseph C. Norton
Joseph C. Norton
KOKeith L. Obstein
Keith L. Obstein
PVPietro Valdastri
Pietro Valdastri
In the present letter, we discuss a novel dynamic control approach for magnetically actuated robots, by proposing an adaptive control technique, robust toward parametric uncertainties and unknown bounded disturbances. The former generally arise due to partial knowledge of the robots' dynamic parameters, such as inertial factors, the latter are the outcome of unpredictable interaction with unstructured environments. In order to show the application of the proposed approach, we consider controlling the magnetic flexible endoscope (MFE), which is composed of a soft-tethered internal permanent magnet (IPM), actuated with a single external permanent magnet. We provide with experimental analysis to show the possibility of levitating the MFE-one of the most difficult tasks with this platform-in case of partial knowledge of the IPM's dynamics and no knowledge of the tether's behavior. Experiments in an acrylic tube show a reduction of contact of the 32% compared to non-levitating techniques and 1.75 times faster task completion with respect to previously proposed levitating techniques. More realistic experiments, performed in a colon phantom, show that levitating the capsule achieves faster and smoother exploration and that the minimum time for completing the task is attained by the proposed approach.

17 September 2020 in Progress in Biomedical Engineering
Verified
Journal Article
Closed access
LBLavinia Barducci
Lavinia Barducci
JNJoseph C Norton
Joseph C Norton
SSSunandita Sarker
Sunandita Sarker
SMSayeed Mohammed
Sayeed Mohammed
RJRyan Jones
Ryan Jones
BTBenjamin S Terry
Benjamin S Terry
The gastrointestinal (GI) tract is a complex environment comprised of the mouth, esophagus, stomach, small and large intestines, rectum and anus, which all cooperate to form the complete working GI system. Access to the GI using endoscopy has been augmented over the past several decades by swallowable diagnostic electromechanical devices, such as pill cameras. Research continues today and into the foreseeable future on new and more capable miniature devices for the purposes of systemic drug delivery, therapy, tissue biopsy, microbiome sampling, and a host of other novel ground-breaking applications. The purpose of this review is to provide engineers in this field a comprehensive reference manual of the GI environment and its complex physical, biological, and chemical characteristics so they can more quickly understand the constraints and challenges associated with developing devices for the GI space. To accomplish this, the work reviews and summarizes a broad spectrum of literature covering the main anatomical and physiological properties of the GI tract that are pertinent to successful development and operation of an electromechanical device. Each organ in the GI is discussed in this context, including the main mechanisms of digestion, chemical and mechanical processes that could impact devices, and GI motor behavior and resultant forces that may be experienced by objects as they move through the environment of the gut.

29 June 2022 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
JMJames W. Martin
James W. Martin
LBLavinia Barducci
Lavinia Barducci
Bruno ScaglioniBruno Scaglioni
Bruno Scaglioni
JNJoseph C. Norton
Joseph C. Norton
CWConchubhair Winters
Conchubhair Winters
PVPietro Valdastri
Pietro Valdastri
Magnetically actuated endoscopes are currently transitioning in to clinical use for procedures such as colonoscopy, presenting numerous benefits over their conventional counterparts. Intelligent and easy-to-use control strategies are an essential part of their clinical effectiveness due to the un-intuitive nature of magnetic field interaction. However, work on developing intelligent control for these devices has mainly been focused on general purpose endoscope navigation. In this work, we investigate the use of autonomous robotic control for magnetic colonoscope intervention via biopsy, another major component of clinical viability. We have developed control strategies with varying levels of robotic autonomy, including semi-autonomous routines for identifying and performing targeted biopsy, as well as random quadrant biopsy. We present and compare the performance of these approaches to magnetic endoscope biopsy against the use of a standard flexible endoscope on bench-top using a colonoscopy training simulator and silicone colon model. The semi-autonomous routines for targeted and random quadrant biopsy were shown to reduce user workload with comparable times to using a standard flexible endoscope.