Xiaogang Liu

Xiaogang Liu

Auto-generated profile, based on publicly available information

Xiaogang Liu

Department of Gastroenterology and Hepatology, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu, Sichuan Province, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2019 in Gut
Verified
Journal Article
Open access
PDF file
PWPu Wang
Pu Wang
TBTyler M Berzin
Tyler M Berzin
JBJeremy Romek Glissen Brown
Jeremy Romek Glissen Brown
SBShishira Bharadwaj
Shishira Bharadwaj
ABAymeric Becq
Aymeric Becq
XLXiaogang Liu
Xiaogang Liu
Objective The effect of colonoscopy on colorectal cancer mortality is limited by several factors, among them a certain miss rate, leading to limited adenoma detection rates (ADRs). We investigated the effect of an automatic polyp detection system based on deep learning on polyp detection rate and ADR. Design In an open, non-blinded trial, consecutive patients were prospectively randomised to undergo diagnostic colonoscopy with or without assistance of a real-time automatic polyp detection system providing a simultaneous visual notice and sound alarm on polyp detection. The primary outcome was ADR. Results Of 1058 patients included, 536 were randomised to standard colonoscopy, and 522 were randomised to colonoscopy with computer-aided diagnosis. The artificial intelligence (AI) system significantly increased ADR (29.1%vs20.3%, p<0.001) and the mean number of adenomas per patient (0.53vs0.31, p<0.001). This was due to a higher number of diminutive adenomas found (185vs102; p<0.001), while there was no statistical difference in larger adenomas (77vs58, p=0.075). In addition, the number of hyperplastic polyps was also significantly increased (114vs52, p<0.001). Conclusions In a low prevalent ADR population, an automatic polyp detection system during colonoscopy resulted in a significant increase in the number of diminutive adenomas detected, as well as an increase in the rate of hyperplastic polyps. The cost–benefit ratio of such effects has to be determined further. Trial registration number ChiCTR-DDD-17012221; Results.

10 October 2018 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
PWPu Wang
Pu Wang
XXXiao Xiao
Xiao Xiao
JBJeremy R. Glissen Brown
Jeremy R. Glissen Brown
TBTyler M. Berzin
Tyler M. Berzin
MTMengtian Tu
Mengtian Tu
XLXiaogang Liu
Xiaogang Liu

7 June 2019 in Endoscopy
Verified
Journal Article
Open access
PDF file
XHXiao Hu
Xiao Hu
YYYun-Chao Yang
Yun-Chao Yang
XLXiao-Gang Liu
Xiao-Gang Liu
Renyi ZhangRenyi Zhang
Renyi Zhang
SHSheng-Xi Han
Sheng-Xi Han
WLWei-hui Liu
Wei-hui Liu
The adequate exposure of the ampullary orifice and reliable fixation of the duodenal papilla are always the basic principles of successful cannulation during endoscopic retrograde cholangiopancreatography (ERCP). In recent years, several traction strategies have proven to be effective in eversion of a hidden papilla within a large diverticulum, such as using a cannula [1], endobiliary forceps [2], or the SpyBite [3] to manipulate the papilla. However, with the above coaxial lifting strategies, it is not possible to optionally adjust the direction and intensity of traction because of interference with the duodenoscope. Therefore, here we report a novel clip-and-snare traction (CST) method to effectively accomplish successful biliary cannulation ([Video 1]), which had not been possible with guidewire-aided cannulation techniques. Video 1 In a patient undergoing endoscopic retrograde cholangiopancreatography for biliary stones, an intradiverticular papilla meant access to the bile duct failed, despite multiple attempts at traditional guidewire-aided cannulation. An endoclip was inserted through the endoscope to grasp the papilla and was interlinked with a snare. The clip-and-snare traction (CST) tools were used to pull the papilla out of the diverticulum, thereby clearly exposing the ampullary orifice. With the CST-assisted cannulation technique, the first guidewire was rapidly advanced into the pancreatic duct and, after several attempts, the bile duct was successfully cannulated with a second guidewire. The patient was being treated by ERCP for common bile duct stones. Attempts were made to access the biliary tree using the guidewire-aided cannulation technique; however, as the ampulla of Vater was hidden inside a diverticulum, attempts to gain access were unsuccessful and, after 15 minutes, the mucosa of the papilla became swollen, with the orifice of papilla becoming obscured ([Fig. 1 a]). Subsequently, the CST method was applied to pull the papilla back out of the diverticulum and the ampullary orifice was eventually turned outward. After several attempts at cannulation, the guidewire smoothly advanced into pancreatic duct ([Fig. 1 b, c]). Attempts were made to perform biliary cannulation in the region towards the upper left orifice of the papilla using a sphincterotome with a second guidewire, and a successful cannulation of the bile duct was finally achieved ([Fig. 1 d, e]). In this patient, the independent lifting technique of CST was employed to optimize the position of the papilla and its orifice by free movements of pull, push, pick, and rotate ([Fig. 2]), which led to successful biliary cannulation in a short time. As the CST method is very simple to manipulate, it may be applied to routine biliary cannulation in any patients where a lifting technique is required. Endoscopy_UCTN_Code_TTT_1AQ_2AC * Contributed equally to this work – both 1st author