Omid Zarini

Omid Zarini

Auto-generated profile, based on publicly available information

Omid Zarini

Helmholtz-Zentrum Dresden–Rossendorf, Bautzner Landstraße 400, 01328 Dresden, Germany

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
JCJ. P. Couperus
J. P. Couperus
RPRichard Pausch
Richard Pausch
AKA. Köhler
A. Köhler
OZO. Zarini
O. Zarini
JKJ. M. Krämer
J. M. Krämer
AIA. Irman
A. Irman
Laser-plasma wakefield accelerators have seen tremendous progress, now capable of producing quasi-monoenergetic electron beams in the GeV energy range with few-femtoseconds bunch duration. Scaling these accelerators to the nanocoulomb range would yield hundreds of kiloamperes peak current and stimulate the next generation of radiation sources covering high-field THz, high-brightness X-ray and γ-ray sources, compact free-electron lasers and laboratory-size beam-driven plasma accelerators. However, accelerators generating such currents operate in the beam loading regime where the accelerating field is strongly modified by the self-fields of the injected bunch, potentially deteriorating key beam parameters. Here we demonstrate that, if appropriately controlled, the beam loading effect can be employed to improve the accelerator’s performance. Self-truncated ionization injection enables loading of unprecedented charges of ∼0.5 nC within a mono-energetic peak. As the energy balance is reached, we show that the accelerator operates at the theoretically predicted optimal loading condition and the final energy spread is minimized.

20 July 2017 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
USUlrich Schramm
Ulrich Schramm
MBM Bussmann
M Bussmann
AIA Irman
A Irman
MSM Siebold
M Siebold
KZK Zeil
K Zeil
OZO Zarini
O Zarini
We report on first commissioning results of the DRACO Petawatt ultra-short pulse laser system implemented at the ELBE center for high power radiation sources of Helmholtz-Zentrum Dresden-Rossendorf. Key parameters of the laser system essential for efficient and reproducible performance of plasma accelerators are presented and discussed with the demonstration of 40 MeV proton acceleration under TNSA conditions as well as peaked electron spectra with unprecedented bunch charge in the 0.5 nC range.

1 September 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
TKThomas Kurz
Thomas Kurz
JCJurjen Pieter Couperus
Jurjen Pieter Couperus
JKJakob Matthias Krämer
Jakob Matthias Krämer
HDHao Ding
Hao Ding
SKStephan Kuschel
Stephan Kuschel
SKStefan Karsch
Stefan Karsch
We revise the calibration of scintillating screens commonly used to detect relativistic electron beams with low average current, e.g., from laser-plasma accelerators, based on new and expanded measurements that include higher charge density and different types of screens than previous work [Buck et al., Rev. Sci. Instrum. 81, 033301 (2010)]. Electron peak charge densities up to 10 nC/mm2 were provided by focused picosecond-long electron beams delivered by the Electron Linac for beams with high Brilliance and low Emittance (ELBE) at the Helmholtz-Zentrum Dresden-Rossendorf. At low charge densities, a linear scintillation response was found, followed by the onset of saturation in the range of nC/mm2. The absolute calibration factor (photons/sr/pC) in this linear regime was measured to be almost a factor of 2 lower than that reported by Buck et al. retrospectively implying a higher charge in the charge measurements performed with the former calibration. A good agreement was found with the results provided by Glinec et al. [Rev. Sci. Instrum. 77, 103301 (2006)]. Furthermore long-term irradiation tests with an integrated dose of approximately 50 nC/mm2 indicate a significant decrease of the scintillation efficiency over time. Finally, in order to enable the transfer of the absolute calibration between laboratories, a new constant reference light source has been developed.

23 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JKJ. M. Krämer
J. M. Krämer
AJA. Jochmann
A. Jochmann
MBM. Budde
M. Budde
MBM. Bussmann
M. Bussmann
JCJ. P. Couperus
J. P. Couperus
AIA. Irman
A. Irman
Interaction of relativistic electron beams with high power lasers can both serve as a secondary light source and as a novel diagnostic tool for various beam parameters. For both applications, it is important to understand the dynamics of the inverse Compton scattering mechanism and the dependence of the scattered light’s spectral properties on the interacting laser and electron beam parameters. Measurements are easily misinterpreted due to the complex interplay of the interaction parameters. Here we report the potential of inverse Compton scattering as an advanced diagnostic tool by investigating two of the most influential interaction parameters, namely the laser intensity and the electron beam emittance. Established scaling laws for the spectral bandwidth and redshift of the mean scattered photon energy are refined. This allows for a quantitatively well matching prediction of the spectral shape. Driving the interaction to a nonlinear regime, we spectrally resolve the rise of higher harmonic radiation with increasing laser intensity. Unprecedented agreement with 3D radiation simulations is found, showing the good control and characterization of the interaction. The findings advance the interpretation of inverse Compton scattering measurements into a diagnostic tool for electron beams from laser plasma acceleration.

1 September 2016 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
JCJ.P. Couperus
J.P. Couperus
AKA. Köhler
A. Köhler
TWT.A.W. Wolterink
T.A.W. Wolterink
AJA. Jochmann
A. Jochmann
OZO. Zarini
O. Zarini
USUlrich Schramm
Ulrich Schramm

5 March 2018 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
PDF file
AIArie Irman
Arie Irman
JCJurjen Couperus
Jurjen Couperus
ADAlexander D Debus
Alexander D Debus
AKAlexander Köhler
Alexander Köhler
JKJakob Krämer
Jakob Krämer
AKAlexander Koehler
Alexander Koehler
We report on tailoring ionization-induced injection in laser wakefield acceleration so that the electron injection process is self-truncating following the evolution of the plasma bubble. Robust generation of high-quality electron beams with shot-to-shot fluctuations of the beam parameters better than 10% is presented in detail. As a novelty, the scheme was found to enable well-controlled yet simple tuning of the injected charge while preserving acceleration conditions and beam quality. Quasi-monoenergetic electron beams at several 100 MeV energy and 15% relative energy spread were routinely demonstrated with a total charge of the monoenergetic feature reaching 0.5 nC. Finally these unique beam parameters, suggesting unprecedented peak currents of several 10 kA, are systematically related to published data on alternative injection schemes.