Mohammed Ibbini

Mohammed Ibbini

Auto-generated profile, based on publicly available information

Mohammed Ibbini

Department of Biomedical Engineering, Jordan University of Science and Technology, Irbid, Jordan

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1990 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
PDF file
MIM. S. Ibbini
M. S. Ibbini
CCC. A. Cain
C. A. Cain
While two-dimensional phased arrays can be electronically focused and steered in three dimensions without physically moving the applicator, they generally require a relatively large number of small transducer elements and, consequently, complex drive electronics. A configuration that does not require a large number of elements is that of a concentric-ring array. The field conjugation method can be used to produce a focal spot (or multiple spots) along the array axis. The resulting focal regions are very small and need to be steered transversely to heat tumours of typical size. However, steering the focused beam away from the array axis results in annular heating patterns which are often associated with undesired secondary foci (hot spots). In this paper, a method based on combining electrical and mechanical scanning using a concentric-ring applicator is presented. Advantages of the new method over the mechanically scanned fixed-focus transducers, currently in use, are pointed out. Computer simulations are conducted to investigate the possibility of heating different size tumours by appropriately combining the two scanning techniques. The bioheat transfer equation is solved numerically and temperature distributions associated with relevant heating patterns are presented and discussed. The simulations demonstrate the possibility of the combined technique to produce useful heating patterns which cannot be produced by either technique separately.

5 September 2025 in IEEE Open Journal of Instrumentation and Measurement
Verified
Journal Article
Open access
TATareq Almustafa
Tareq Almustafa
BABilel Ben Atitallah
Bilel Ben Atitallah
KLKhaldon Lweesy
Khaldon Lweesy
MIMohammed Ibbini
Mohammed Ibbini
Olfa KanounOlfa Kanoun
Olfa Kanoun
This study investigates the potential of impedimetric measurements providing deep muscle information for recognizing 36 American Sign Language (ASL) hand signs. Two measurement methods are considered together for the first time: electrical impedance myography (EIM) and electrical impedance tomography (EIT). EIM was measured along the anterior forearm, while 8-electrode EIT was recorded around the forearm below the elbow. Data were acquired from three volunteers, with each hand sign performed ten times. A correlation analysis was conducted to identify the relevant EIM frequencies to distinguish between hand signs. Among all evaluated algorithms, the random forest classifier achieves the highest classification performance. Classification based on the resistance and reactance at the selected EIM frequencies achieved 61.54 ± 0.85%, while classification based on EIT boundary voltages achieved 91.04% ± 0.46%. Combining the results from both classifiers into an EIM-EIT hybrid classifier improved the accuracy to 92.57 ± 0.41%, effectively reducing ambiguities between similar hand signs. Achieved results considerably outperform state-of-the-art works, which typically classify fewer hand signs or achieve lower accuracy.