D Lab, Department of Computerization, Automation and Medical Technology (iMED), OLVG Hospital, 9 Oosterpark, Amsterdam, 1091 AC, The Netherlands, 31 020 599 91 11
Auto-generated profile, based on publicly available information
Susan Gijsbertje Brouwer de Koning
D Lab, Department of Computerization, Automation and Medical Technology (iMED), OLVG Hospital, 9 Oosterpark, Amsterdam, 1091 AC, The Netherlands, 31 020 599 91 11
Objective: The utilization of hyperspectral imaging (HSI) in real-time tumor segmentation during a surgery have recently received much attention, but it remains a very challenging task. Methods: In this work, we propose semantic segmentation methods and compare them with other relevant deep learning algorithms for tongue tumor segmentation. To the best of our knowledge, this is the first work using deep learning semantic segmentation for tumor detection in HSI data using channel selection and accounting for more spatial tissue context and global comparison between the prediction map and the annotation per sample. Results and Conclusion: On a clinical data set with tongue squamous cell carcinoma, our best method obtains very strong results of average dice coefficient and area under the ROC-curve of 0.891 +/- 0.053 and 0.924 +/- 0.036, respectively on the original spatial image size. The results show that a very good performance can be achieved even with a limited amount of data. We demonstrate that important information regarding tumor decision is encoded in various channels, but some channel selection and filtering is beneficial over the full spectra. Moreover, we use both visual (VIS) and near-infrared (NIR) spectrum, rather than commonly used only VIS spectrum; although VIS spectrum is generally of higher significance, we demonstrate NIR spectrum is crucial for tumor capturing in some cases. Significance: The HSI technology augmented with accurate deep learning algorithms has a huge potential to be a promising alternative to digital pathology or a doctors' supportive tool in real-time surgeries.
Colorectal cancer is the third most commonly diagnosed cancer worldwide and the fourth cause of death due to cancer.1,2 For patients with colorectal cancer, surgery is the cornerstone of the treatment. In the last decades, laparoscopic surgery for colorectal cancer has become common practice. Randomized controlled trials have proven similar clinical outcomes for laparoscopic surgery as for open surgery with a decrease in hospital stay.3 One of the drawbacks of laparoscopic surgery is the reduced tactile feedback during surgery.4,5 The lack of tactile feedback makes tissue recognition more cumbersome, especially in areas where radical resection margins are often compromised, like in locally advanced tumors and in rectal cancer. Hence, an alternative technique that would enable the surgeon to distinguish tumor from normal tissue during laparoscopic surgery in real-time would be of great benefit to secure radical resection in difficult areas, such as in rectal cancer. We will investigate the use of hyperspectral imaging (HSI) as a tool to ensure radical margins in these circumstances, distinguishing tumor from healthy colorectal tissue.
Colorectal surgery is the standard treatment for patients with colorectal cancer. To overcome two of the main challenges, the circumferential resection margin and postoperative complications, real-time tissue assessment could be of great benefit during surgery. In this ex vivo study, diffuse reflectance spectroscopy (DRS) was used to differentiate tumor tissue from healthy surrounding tissues in patients with colorectal neoplasia. DRS spectra were obtained from tumor tissue, healthy colon, or rectal wall and fat tissue, for every patient. Data were randomly divided into training (80%) and test (20%) sets. After spectral band selection, the spectra were classified using a quadratic classifier and a linear support vector machine. Of the 38 included patients, 36 had colorectal cancer and 2 had an adenoma. When the classifiers were applied to the test set, colorectal cancer could be discriminated from healthy tissue with an overall accuracy of 0.95 (±0.03). This study demonstrates the possibility to separate colorectal cancer from healthy surrounding tissue by applying DRS. High classification accuracies were obtained both in homogeneous and inhomogeneous tissues. This is a fundamental step toward the development of a tool for real-time in vivo tissue assessment during colorectal surgery.
1 September 2021 in European Journal of Surgical Oncology
This ex-vivo study evaluates the feasibility of diffuse reflectance spectroscopy (DRS) for discriminating tumor from healthy tissue, with the aim to develop a technology that can assess resection margins for the presence of tumor cells during oral cavity cancer surgery. Diffuse reflectance spectra were acquired on fresh surgical specimens from 28 patients with oral cavity squamous cell carcinoma. The spectra (400 to 1600 nm) were detected after illuminating tissue with a source fiber at 0.3-, 0.7-, 1.0-, and 2.0-mm distances from a detection fiber, obtaining spectral information from different sampling depths. The spectra were correlated with histopathology. A total of 76 spectra were obtained from tumor tissue and 110 spectra from healthy muscle tissue. The first- and second-order derivatives of the spectra were calculated and a classification algorithm was developed using fivefold cross validation with a linear support vector machine. The best results were obtained by the reflectance measured with a 1-mm source–detector distance (sensitivity, specificity, and accuracy are 89%, 82%, and 86%, respectively). DRS can accurately discriminate tumor from healthy tissue in an ex-vivo setting using a 1-mm source–detector distance. Accurate validation methods are warranted for larger sampling depths to allow for guidance during oral cavity cancer excision.