This paper introduces the novel concept of using Set-Valued Observers (SVOs) in Fault Detection and Isolation (FDI), for discrete-time linear time-varying systems. The proposed method relies on SVO-based model invalidation to discard models that are not compatible with the input/output data. We argue that there are mainly three significant advantages of using SVOs for FDI, when compared to the most common strategies available in the literature: i) under suitable conditions, we can guarantee that there will be no false alarms; ii) unlike residual-based architectures, the proposed technique does not require the computation of a threshold to declare faults; iii) the SVOs can be used with a wide class of time-varying linear uncertain discrete-time systems. We further show, in simulation, that the proposed FDI algorithm in general requires a very small number of iterations to detect and identify a faulty behavior.
5 June 2014 in IEEE Transactions on Control Systems Technology
A complete methodology to design robust fault detection and isolation (FDI) filters and fault-tolerant control (FTC) schemes for linear parameter varying systems is proposed, with particular focus on its applicability to wind turbines. This paper takes advantage of the recent advances in model falsification using set-valued observers (SVOs) that led to the development of FDI methods for uncertain linear time-varying systems, with promising results in terms of the time required to diagnose faults. An integration of such SVO-based FDI methods with robust control synthesis is described, to deploy new FTC algorithms that are able to stabilize the plant under faulty environments. The FDI and FTC algorithms are assessed by resorting to a publicly available wind turbine benchmark model, using Monte Carlo simulation runs.
This paper introduces the notion of absolutely distinguishable discrete dynamic systems, with particular applicability to linear time-invariant (LTI) systems. The motivation for this novel type of distinguishability stems, in particular, from the stability and performance requirements of worst-case adaptive control methodologies. The main results presented herein show that, in most practical cases, a persistence of excitation type of condition and a minimum number of iterations are required to properly distinguish two dynamic systems. We also demonstrate that the former constraint can be written as a lower bound on the intensity of the exogenous disturbances. The applicability of the developed theory is illustrated with a set of examples.