Lucien E. Weiss

Lucien E. Weiss

Auto-generated profile, based on publicly available information

Lucien E. Weiss

Department of Engineering Physics, Polytechnique Montréal

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2018 in Optica
Verified
Journal Article
Open access
PDF file
ENElias Nehme
Elias Nehme
LWLucien E. Weiss
Lucien E. Weiss
TMTomer Michaeli
Tomer Michaeli
YSYoav Shechtman
Yoav Shechtman
We present an ultrafast, precise, parameter-free method, which we term Deep-STORM, for obtaining super-resolution images from stochastically blinking emitters, such as fluorescent molecules used for localization microscopy. Deep-STORM uses a deep convolutional neural network that can be trained on simulated data or experimental measurements, both of which are demonstrated. The method achieves state-of-the-art resolution under challenging signal-to-noise conditions and high emitter densities and is significantly faster than existing approaches. Additionally, no prior information on the shape of the underlying structure is required, making the method applicable to any blinking dataset. We validate our approach by super-resolution image reconstruction of simulated and experimentally obtained data.

15 June 2020 in Nature Methods
Verified
Journal Article
Closed access
PDF file
ENElias Nehme
Elias Nehme
DFDaniel Freedman
Daniel Freedman
RGRacheli Gordon
Racheli Gordon
BFBoris Ferdman
Boris Ferdman
LWLucien E. Weiss
Lucien E. Weiss
YSYoav Shechtman
Yoav Shechtman

5 May 2015 in Nano Letters
Verified
Journal Article
Open access
YSYoav Shechtman
Yoav Shechtman
LWLucien E. Weiss
Lucien E. Weiss
ABAdam S. Backer
Adam S. Backer
SSSteffen J. Sahl
Steffen J. Sahl
WMW. E. Moerner
W. E. Moerner
We employ a novel framework for information-optimal microscopy to design a family of point spread functions (PSFs), the Tetrapod PSFs, which enable high-precision localization of nanoscale emitters in three dimensions over customizable axial (z) ranges of up to 20 μm with a high numerical aperture objective lens. To illustrate, we perform flow profiling in a microfluidic channel and show scan-free tracking of single quantum-dot-labeled phospholipid molecules on the surface of living, thick mammalian cells.

1 July 2019 in Biophysical Journal
Verified
Journal Article
Closed access
NGNaor Granik
Naor Granik
LWLucien E. Weiss
Lucien E. Weiss
ENElias Nehme
Elias Nehme
MLMaayan Levin
Maayan Levin
MCMichael Chein
Michael Chein
YSYoav Shechtman
Yoav Shechtman

5 May 2009 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
TCTzahi Cohen-Karni
Tzahi Cohen-Karni
BTBrian P. Timko
Brian P. Timko
LWLucien E. Weiss
Lucien E. Weiss
CLCharles Lieber
Charles Lieber
Semiconductor nanowires (NWs) have unique electronic properties and sizes comparable with biological structures involved in cellular communication, thus making them promising nanostructures for establishing active interfaces with biological systems. We report a flexible approach to interface NW field-effect transistors (NWFETs) with cells and demonstrate this for silicon NWFET arrays coupled to embryonic chicken cardiomyocytes. Cardiomyocyte cells were cultured on thin, optically transparent polydimethylsiloxane (PDMS) sheets and then brought into contact with Si-NWFET arrays fabricated on standard substrates. NWFET conductance signals recorded from cardiomyocytes exhibited excellent signal-to-noise ratios with values routinely >5 and signal amplitudes that were tuned by varying device sensitivity through changes in water gate–voltage potential, V g . Signals recorded from cardiomyocytes for V g from −0.5 to +0.1 V exhibited amplitude variations from 31 to 7 nS whereas the calibrated voltage remained constant, indicating a robust NWFET/cell interface. In addition, signals recorded as a function of increasing/decreasing displacement of the PDMS/cell support to the device chip showed a reversible >2× increase in signal amplitude (calibrated voltage) from 31 nS (1.0 mV) to 72 nS (2.3 mV). Studies with the displacement close to but below the point of cell disruption yielded calibrated signal amplitudes as large as 10.5 ± 0.2 mV. Last, multiplexed recording of signals from NWFET arrays interfaced to cardiomyocyte monolayers enabled temporal shifts and signal propagation to be determined with good spatial and temporal resolution. Our modular approach simplifies the process of interfacing cardiomyocytes and other cells to high-performance Si-NWFETs, thus increasing the experimental versatility of NWFET arrays and enabling device registration at the subcellular level.

8 August 2016 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
YSYoav Shechtman
Yoav Shechtman
LWLucien E. Weiss
Lucien E. Weiss
ABAdam S. Backer
Adam S. Backer
MLMaurice Y. Lee
Maurice Y. Lee
WMW. E. Moerner
W. E. Moerner