Zhuo Deng

Zhuo Deng

Auto-generated profile, based on publicly available information

Zhuo Deng

Shenzhen International Graduate School, Tsinghua University, Shenzhen, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
ZDZhuo Deng
Zhuo Deng
YCYuanhao Cai
Yuanhao Cai
LCLu Chen
Lu Chen
ZGZheng Gong
Zheng Gong
QBQiqi Bao
Qiqi Bao
LMLan Ma
Lan Ma
Ophthalmologists have used fundus images to screen and diagnose eye diseases. However, different equipments and ophthalmologists pose large variations to the quality of fundus images. Low-quality (LQ) degraded fundus images easily lead to uncertainty in clinical screening and generally increase the risk of misdiagnosis. Thus, real fundus image restoration is worth studying. Unfortunately, real clinical benchmark has not been explored for this task so far. In this paper, we investigate the real clinical fundus image restoration problem. Firstly, We establish a clinical dataset, Real Fundus (RF), including 120 low- and high-quality (HQ) image pairs. Then we propose a novel Transformer-based Generative Adversarial Network (RFormer) to restore the real degradation of clinical fundus images. The key component in our network is the Window-based Self-Attention Block (WSAB) which captures non-local self-similarity and long-range dependencies. To produce more visually pleasant results, a Transformer-based discriminator is introduced. Extensive experiments on our clinical benchmark show that the proposed RFormer significantly outperforms the state-of-the-art (SOTA) methods. In addition, experiments of downstream tasks such as vessel segmentation and optic disc/cup detection demonstrate that our proposed RFormer benefits clinical fundus image analysis and applications.

22 October 2024 in Artificial Intelligence in Medicine
Verified
Journal Article
Open access
ZDZhuo Deng
Zhuo Deng
WGWeihao Gao
Weihao Gao
CCChucheng Chen
Chucheng Chen
ZNZhiyuan Niu
Zhiyuan Niu
ZGZheng Gong
Zheng Gong
LMLan MA
Lan MA
Vision computer-aided diagnostic methods have been used in early ophthalmic disease screening and diagnosis. However, the limited output formats of these methods lead to poor human-computer interaction and low clinical applicability value. Thus, ophthalmic visual question answering is worth studying. Unfortunately, no practical solutions exist before Large Language Models(LLMs). In this paper, we investigate the ophthalmic visual diagnostic interaction problem. We construct an ophthalmology large language-and-vision assistant, OphGLM, consisting of an image encoder, a text encoder, a fusion module, and an LLM module. We establish a new Chinese ophthalmic fine-tuning dataset, FundusTuning-CN, including the fundus instruction and conversation sets. Based on FundusTuning-CN, we establish a novel LLM-tuning strategy to introduce visual model understanding and ophthalmic knowledge into LLMs at a low cost and high efficiency. Leveraging the pre-training of the image encoder, OphGLM demonstrates strong visual understanding and surpasses open-source visual language models in common fundus disease classification tasks. The FundusTuning-CN enables OphGLM to surpass open-source medical LLMs in both ophthalmic knowledge and interactive capabilities. Our proposed OphGLM has the potential to revolutionize clinical applications in ophthalmology. The dataset, code, and models will be publicly available at https://github.com/ML-AILab/OphGLM.

25 October 2025 in Knowledge-Based Systems
Verified
Journal Article
Open access
WGWeihao Gao
Weihao Gao
ZGZheng Gong
Zheng Gong
ZDZhuo Deng
Zhuo Deng
LMLan Ma
Lan Ma

3 December 2024 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
ZCZhenjie Cao
Zhenjie Cao
ZDZhuo Deng
Zhuo Deng
ZYZhicheng Yang
Zhicheng Yang
JYJialin Yuan
Jialin Yuan
JMJie Ma
Jie Ma
LMLan MA
Lan MA
Early asymmetry (AS) and architectural distortion (AD) detection on mammograms are essential in breast cancer diagnosis. However, they are challenging as the prevalence of AS and AD is very low. This paper proposes an efficient AsyDisNet for the AS and AD detection. First, a novel angle-based quadruplet loss is proposed to detect the AS and AD with limited pixel-level labeled mammograms. Second, we scale the AsyDisNet with a novel semi-weakly supervised learning framework to boost the detection performance with a large number of mammograms with image-level labels extracted from medical reports. The validation on the two largest and privately collected datasets shows an average of ~ 10% improvement over State-of-the-Art baselines in terms of sensitivities under various false-positive-per-image (FPPI). Furthermore, the proposed AsyDisNet is scalable to the current Picture Archiving and Communication System (PACS) with incremental learning ability. The dataset will be made publicly available at https://github.com/ML-AILab/AsyDisNet.

23 June 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
ZZZiheng Zhang
Ziheng Zhang
DCDefeng Cai
Defeng Cai
ZDZhuo Deng
Zhuo Deng
ZDZhicheng Du
Zhicheng Du
FZFuxing Zhang
Fuxing Zhang
LMLan MA
Lan MA
Background/Objectives: The accuracy and reliability of automated clinical analyzers are fundamental to patient safety and effective medical decision-making. Traditional quality control (QC) methods, which rely on periodic manual calibration and reactive maintenance, are inherently limited by high latency and labor costs; furthermore, they fail to provide continuous, real-time monitoring. This paper introduces a novel hybrid ensemble learning framework for the automated quality inspection of medical devices through the analysis of time-series reaction curves. Methods: Our system integrates three heterogeneous anomaly detection paradigms: an Enhanced Dynamic Time Warping (DTW) detector for robust non-linear pattern matching, a Shape Template Matching (STM) detector that mimics expert clinical logic by analyzing morphological features in a normalized shape space, and a specialized Time-series Variational Autoencoder (TimeVAE) for deep representation learning. The outputs of these detectors are fused using a weighted ensemble strategy, which is specifically designed to prioritize the minimization of false negatives—a critical requirement in medical diagnostics. Results: We evaluate our framework on a comprehensive, multi-center real-world dataset comprising seven distinct biochemical assays. Experimental results demonstrate that our proposed method achieves superior performance, attaining a 0% false negative rate on CRE and DBIL assays and outperforming all baseline methods on the other five datasets. An ablation study confirms the model’s robustness even with limited training data, and a comparative analysis against eight state-of-the-art baseline methods further validates the effectiveness of our domain-optimized ensemble approach. Conclusions: The system provides a robust, interpretable, and highly automated solution for transitioning from reactive maintenance to proactive, real-time quality assurance in clinical laboratories.

22 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
SBShurui Bai
Shurui Bai
ZDZhuo Deng
Zhuo Deng
JYJingyan Yang
Jingyan Yang
ZGZheng Gong
Zheng Gong
WGWeihao Gao
Weihao Gao
LMLan MA
Lan MA
The segmentation of fundus tumors is critical for ophthalmic diagnosis and treatment, yet it presents unique challenges due to the variability in lesion size and shape. Our study introduces Fundus Tumor Segmentation Network (FTSNet), a novel segmentation network designed to address these challenges by leveraging classification results and prompt learning. Our key innovation is the multiscale feature extractor and the dynamic prompt head. Multiscale feature extractors are proficient in eliciting a spectrum of feature information from the original image across disparate scales. This proficiency is fundamental for deciphering the subtle details and patterns embedded in the image at multiple levels of granularity. Meanwhile, a dynamic prompt head is engineered to engender bespoke segmentation heads for each image, customizing the segmentation process to align with the distinctive attributes of the image under consideration. We also present the Fundus Tumor Segmentation (FTS) dataset, comprising 254 pairs of fundus images with tumor lesions and reference segmentations. Experiments demonstrate FTSNet’s superior performance over existing methods, achieving a mean Intersection over Union (mIoU) of 0.8254 and mean Dice (mDice) of 0.9042. The results highlight the potential of our approach in advancing the accuracy and efficiency of fundus tumor segmentation.