Kathleen Mantell

Kathleen Mantell

Auto-generated profile, based on publicly available information

Kathleen Mantell

Department of Biomedical Engineering, University of Minnesota

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in NeuroImage
Verified
Journal Article
Closed access
IAIvan Alekseichuk
Ivan Alekseichuk
KMKathleen Mantell
Kathleen Mantell
SSSina Shirinpour
Sina Shirinpour
AOAlexander Opitz
Alexander Opitz

1 November 2021 in Neuroscience & Biobehavioral Reviews
Verified
Journal Article
Closed access
MWMiles Wischnewski
Miles Wischnewski
KMKathleen E. Mantell
Kathleen E. Mantell
AOAlexander Opitz
Alexander Opitz

8 July 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
SSSina Shirinpour
Sina Shirinpour
IAIvan Alekseichuk
Ivan Alekseichuk
KMKathleen Mantell
Kathleen Mantell
AOAlexander Opitz
Alexander Opitz
Objective. Real-time approaches for transcranial magnetic stimulation (TMS) based on a specific EEG phase are a promising avenue for more precise neuromodulation interventions. However, optimal approaches to reliably extract the EEG phase in a frequency band of interest to inform TMS are still to be identified. Here, we implement a new real-time phase detection method for closed-loop EEG-TMS for robust phase extraction. We compare this algorithm with state-of-the-art methods and evaluate its performance both in silico and experimentally. Approach. We propose a new robust algorithm (Educated Temporal Prediction) for delivering real-time EEG phase-specific stimulation based on short prerecorded EEG training data. This method estimates the interpeak period from a training period and applies a bias correction to predict future peaks. We compare the accuracy and computation speed of the ETP algorithm with two existing methods (Fourier based, Autoregressive Prediction) using prerecorded resting EEG data and real-time experiments. Main results . We found that Educated Temporal Prediction performs with higher accuracy than Fourier-based or Autoregressive methods both in silico and in vivo while being computationally more efficient. Further, we document the dependency of the EEG signal-to-noise ratio (SNR) on algorithm accuracy across all algorithms. Significance . Our results give important insights for real-time EEG-TMS technical development as well as experimental design. Due to its robustness and computational efficiency, our method can find broad use in experimental research or clinical applications. Through open sharing of code for all three methods, we enable broad access of TMS-EEG real-time algorithms to the community.

1 January 2021 in NeuroImage: Clinical
Verified
Journal Article
Open access
KMKathleen E. Mantell
Kathleen E. Mantell
ESEllen N Sutter
Ellen N Sutter
SSSina Shirinpour
Sina Shirinpour
SNSamuel T. Nemanich
Samuel T. Nemanich
DLDaniel H. Lench
Daniel H. Lench
AOAlexander Opitz
Alexander Opitz
Transcranial magnetic stimulation (TMS) is an increasingly popular tool for stroke rehabilitation. Consequently, researchers have started to explore the use of TMS in pediatric stroke. However, the application of TMS in a developing brain with pathologies comes with a unique set of challenges. The effect of TMS-induced electric fields has not been explored in children with stroke lesions. Here, we used finite element method (FEM) modeling to study how the electric field strength is affected by the presence of a lesion. We created individual realistic head models from MRIs (n = 6) of children with unilateral cerebral palsy due to perinatal stroke. We conducted TMS electric field simulations for coil locations over lesioned and non-lesioned hemispheres. We found that the presence of a lesion can strongly affect the electric field distribution. On the group level, the mean electric field strength did not differ between lesioned and non-lesioned hemispheres but exhibited a greater variability in the lesioned hemisphere. Other factors such as coil-to-cortex distance have a strong influence on the TMS electric field even in the presence of lesions. Our study has important implications for the delivery of TMS in children with brain lesions with respect to TMS dosing and coil placement.

30 November 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
SSSina Shirinpour
Sina Shirinpour
IAIvan Alekseichuk
Ivan Alekseichuk
KMKathleen Mantell
Kathleen Mantell
AOAlexander Opitz
Alexander Opitz
Brain oscillations reflect system-level neural dynamics and capture the current brain state. These brain rhythms can be measured noninvasively in humans with electroencephalography (EEG). Up and down states of brain oscillations capture local changes in neuronal excitability. This makes them a promising target for non-invasive brain stimulation methods such as Transcranial Magnetic Stimulation (TMS). Real-time EEG-TMS systems record ongoing brain signals, process the data, and deliver TMS stimuli at a specific brain state. Despite their promise to increase the temporal specificity of stimulation, best practices and technical solutions are still under development. Here, we implement and compare state-of-the-art methods (Fourier based, Autoregressive Prediction) for real-time EEG-TMS and evaluate their performance both in silico and experimentally. We further propose a new robust algorithm for delivering real-time EEG phase-specific stimulation based on short prerecorded EEG training data (Educated Temporal Prediction). We found that Educated Temporal Prediction performs at the same level or better than Fourier-based or Autoregressive methods both in silico and in vivo , while being computationally more efficient. Further, we document a dependency of EEG signal-to-noise ratio (SNR) on algorithm accuracy across all algorithms. In conclusion, our results can give important insights for real-time TMS-EEG technical development as well as experimental design.

13 October 2018 in bioRxiv
Verified
Preprint
Open access
PDF file
IAIvan Alekseichuk
Ivan Alekseichuk
KMKathleen Mantell
Kathleen Mantell
SSSina Shirinpour
Sina Shirinpour
AOAlexander Opitz
Alexander Opitz
Transcranial magnetic stimulation (TMS) and transcranial electric stimulation (TES) are increasingly popular methods to noninvasively affect brain activity. However, their mechanism of action and dose-response characteristics remain under active investigation. Translational studies in animals play a pivotal role in these efforts due to a larger neuroscientific toolset enabled by invasive recordings. In order to translate knowledge gained in animal studies to humans, it is crucial to generate comparable stimulation conditions with respect to the induced electric field in the brain. Here, we conduct a finite element method (FEM) modeling study of TMS and TES electric fields in a mouse, capuchin monkey, and human model. We systematically evaluate the induced electric fields and analyze their relationship to head and brain anatomy. We find that with increasing head size, TMS-induced electric field strength first increases and then decreases according to a two-term exponential function. TES-induced electric field strength strongly decreases from smaller to larger specimen with up to 100x fold differences across species. Our results can serve as a basis to compare and match stimulation parameters across studies in animals and humans. HIGHLIGHTS: Translational research in brain stimulation should account for large differences in induced electric fields in different organisms We simulate TMS and TES electric fields using anatomically realistic finite element models in three species: mouse, monkey, and human TMS with a 70 mm figure-8 coil creates an approximately 2-times weaker electric field in a mouse brain than in monkey and human brains, where electric field strength is comparable Two-electrode TES creates an approximately 100-times stronger electric field in a mouse brain and 3.5-times stronger electric field in a monkey brain than in a human brain