Feyza Şen

Feyza Şen

Auto-generated profile, based on publicly available information

Feyza Şen

Department of Nuclear Medicine Marmara University Pendik Training and Research Hospital Istanbul Turkey

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Molecular Imaging and Radionuclide Therapy
Verified
Journal Article
Open access
SÖSalih Özgüven
Salih Özgüven
NFNuh Filizoğlu
Nuh Filizoğlu
SKSelin Kesim
Selin Kesim
KÖKevser Öksüzoğlu
Kevser Öksüzoğlu
FŞFeyza Şen
Feyza Şen
TETanju Yusuf Erdil
Tanju Yusuf Erdil
Somatostatin is an endocrine peptide hormone that regulates neurotransmission and cell proliferation by interacting with G protein-coupled somatostatin receptors (SSTRs). SSTRs are specific molecular targets of several radiotracers for neuroendocrine tumor (NET) imaging. Gallium-68 (68Ga)-DOTA-TATE is widely used for positron emission tomography/computed tomography (PET/CT) imaging of SSTRs and has shown a higher affinity for SSTR2, the most common SSTR subtype found in NETs. We aimed to analyze the distribution pattern of 68Ga-DOTA-TATE in normal subjects. A total of 617 consecutive 68Ga-DOTA-TATE PET/CT whole-body scans performed in our department from May 2015 through April 2020 with known or suspected neuroendocrine malignancies, mostly to evaluate adrenal adenomas, were retrospectively analyzed by 2 nuclear medicine physicians. One hundred eighteen subjects without a diagnosis of NET, with no tracer avid lesion of NET on 68Ga-DOTA-TATE PET/CT, and followed up for at least 6 months (average 2-3 years) without any biochemical, clinical, or imaging findings suggestive of NET were included in this study. The highest uptake of 68Ga-DOTA-TATE was noted in the spleen followed by the kidneys, adrenal glands, liver, stomach, small intestine, prostate gland, pancreas head, pancreas body, thyroid gland, and uterus, in descending order. Minimal to mild uptake was detected in the submandibular glands, parotid glands, thymus, muscles, bones, breast, lungs, and mediastinum. Our study shows the biodistribution pattern of 68Ga-DOTA-TATE in normal subjects and the ranges of the maximum standard uptake value (SUVmax) and SUVmean values of 68Ga-DOTA-TATE obtained in several tissues for reliably identifying malignancy in 68Ga-DOTA-TATE PET/CT studies.

25 September 2007 in Molecular and Cellular Biochemistry
Verified
Journal Article
Closed access
PDF file
MCMehmet Cabuk
Mehmet Cabuk
AGAhmet Gurel
Ahmet Gurel
FSFeyza Sen
Feyza Sen
NDNejat Demircan
Nejat Demircan

1 February 2021 in Molecular Imaging and Radionuclide Therapy
Verified
Journal Article
Open access
SÖSalih Özgüven
Salih Özgüven
SKSelin Kesim
Selin Kesim
KÖKevser Öksüzoğlu
Kevser Öksüzoğlu
MYMehmed Yanartaş
Mehmed Yanartaş
STSerpil Taş
Serpil Taş
BYBedrettin Yıldızeli
Bedrettin Yıldızeli
Objectives: Chronic thromboembolic pulmonary hypertension (CTEPH) is a type of pulmonary hypertension with persistent pulmonary vascular obstruction and exercise intolerance, which may benefit from pulmonary endarterectomy (PEA). Ventilation/perfusion (V/Q) scan is the preferred screening test of CTEPH, which can be used to assess the anatomical extent of the disease. This study aimed to analyze the correlation between the extent of mismatched Q defects in V/Q single photon emission computed tomography/computed tomography (SPECT/CT) with preoperative clinical and hemodynamic parameters in patients with CTEPH. Methods: A total of 102 patients with CTEPH prior to PEA having V/Q SPECT/CT scans were retrospectively reviewed. Age, gender, New York Heart Association classification, intraoperative right-sided heart catheterization (mPAP and PVR), and 6-minute walk test (6MWT) findings were obtained from clinical records of patients. Results: Linear regression analysis showed a significant but weak correlation between the preoperative mPAP and PVR with the extent of mismatched Q defects in V/Q SPECT/CT (rs=0.09474 with p=0.0016 and rs=0.045 with p=0.045, respectively). No significant correlation was found between 6MWT and extent of mismatched Q defects in V/Q SPECT/CT (p>0.05). Conclusion: A quantitative assessment of Q defects on V/Q SPECT/CT might provide information about hemodynamic parameters in patients with CTEPH.

26 August 2020 in Nuclear Medicine Seminars
Verified
Journal Article
Closed access
FTFevziye Canbaz Tosun
Fevziye Canbaz Tosun
SOSemra OZDEMIR
Semra OZDEMIR
FŞFeyza Şen
Feyza Şen
HDHakan Demir
Hakan Demir
EÖELİF ÖZDEMİR
ELİF ÖZDEMİR
GAGülay Durmuş Altun
Gülay Durmuş Altun

30 July 2023 in World Journal of Surgery
Verified
Journal Article
Closed access
PDF file
AEAhmet Cem Esmer
Ahmet Cem Esmer
KÖKevser Öksüzoğlu
Kevser Öksüzoğlu
FŞFeyza Şen
Feyza Şen
HYHilmi Yazici
Hilmi Yazici
DTDeniz Tazeoğlu
Deniz Tazeoğlu
ŞYŞevket Cumhur Yeğen
Şevket Cumhur Yeğen

26 August 2020 in Nuclear Medicine Seminars
Verified
Journal Article
Closed access
GAGülay Durmuş Altun
Gülay Durmuş Altun
BSBurcu Dirlik Serim
Burcu Dirlik Serim
EÖELİF ÖZDEMİR
ELİF ÖZDEMİR
SOSemra OZDEMIR
Semra OZDEMIR
FŞFeyza Şen
Feyza Şen
FTFevziye Canbaz Tosun
Fevziye Canbaz Tosun