Matthew N. Cramer

Matthew N. Cramer

Auto-generated profile, based on publicly available information

Matthew N. Cramer

Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital Dallas and University of Texas Southwestern Medical Center, Dallas, Texas

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Autonomic Neuroscience
Verified
Journal Article
Closed access
MCMatthew N. Cramer
Matthew N. Cramer
OJOllie Jay
Ollie Jay

13 October 2010 in Experimental Physiology
Verified
Journal Article
Open access
PDF file
JPJulien D. Périard
Julien D. Périard
MCMatthew N. Cramer
Matthew N. Cramer
PCPhillip G. Chapman
Phillip G. Chapman
CCCorinne Caillaud
Corinne Caillaud
MTMartin W. Thompson
Martin W. Thompson
It has been proposed that self‐paced exercise in the heat is regulated by an anticipatory reduction in work rate based on the rate of heat storage. However, performance may be impaired by the develop...

1 May 2014 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
MCMatthew N. Cramer
Matthew N. Cramer
OJOllie Jay
Ollie Jay
We assessed whether comparisons of thermoregulatory responses between groups unmatched for body mass and surface area (BSA) should be performed using a metabolic heat production (Ḣprod) in Watts or Watts per kilogram for changes in rectal temperature (ΔTre), and an evaporative heat balance requirement ( Ereq) in Watts or Watts per square meter for local sweat rates (LSR). Two groups with vastly different mass and BSA [large (LG): 91.5 ± 6.8 kg, 2.12 ± 0.09 m2, n = 8; small (SM): 67.6 ± 5.6 kg, 1.80 ± 0.09 m2, n = 8; P < 0.001], but matched for heat acclimation status, sex, age, and with the same onset threshold esophageal temperatures (LG: +0.37 ± 0.12°C; SM: +0.41 ± 0.17°C; P = 0.364) and thermosensitivities (LG: 1.02 ± 0.54, SM: 1.00 ± 0.38 mg·cm−2·min−1·°C−1; P = 0.918) for sweating, cycled for 60 min in 25°C at different levels of Ḣprod (500 W, 600 W, 6.5 W/kg, 9.0 W/kg) and Ereq (340 W, 400 W, 165 W/m2, 190 W/m2). ΔTre was different between groups at a Ḣprod of 500 W (LG: 0.52 ± 0.15°C, SM: 0.92 ± 0.24°C; P < 0.001) and 600 W (LG: 0.78 ± 0.19°C, SM: 1.14 ± 0.24°C; P = 0.007), but similar at 6.5 W/kg (LG: 0.79 ± 0.21°C, SM: 0.85 ± 0.14°C; P = 0.433) and 9.0 W/kg (LG: 1.02 ± 0.22°C, SM: 1.14 ± 0.24°C; P = 0.303). Furthermore, ΔTre was the same at 9.0 W/kg in a 35°C environment (LG: 1.12 ± 0.30°C, SM: 1.14 ± 0.25°C) as at 25°C ( P > 0.230). End-exercise LSR was different at Ereq of 400 W (LG: 0.41 ± 0.18, SM: 0.57 ± 0.13 mg·cm−2·min−1; P = 0.043) with a trend toward higher LSR in SM at 340 W (LG: 0.28 ± 0.06, SM: 0.37 ± 0.15 mg·cm−2·min−1; P = 0.057), but similar at 165 W/m2 (LG: 0.28 ± 0.06, SM: 0.28 ± 0.12 mg·cm−2·min−1; P = 0.988) and 190 W/m2 (LG: 0.41 ± 0.18, SM: 0.37 ± 0.15 mg·cm−2·min−1; P = 0.902). In conclusion, when comparing groups unmatched for mass and BSA, future experiments can avoid systematic differences in ΔTre and LSR by using a fixed Ḣprod in Watts per kilogram and Ereq in Watts per square meter, respectively.

1 February 2019 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
MCMatthew N. Cramer
Matthew N. Cramer
OJOllie Jay
Ollie Jay
For thermal physiologists, calorimetry is an important methodological tool to assess human heat balance during heat or cold exposures. A whole-body direct calorimeter remains the gold standard instrument for assessing human heat balance; however, this equipment is rarely available to most researchers. A more widely accessible substitute is partitional calorimetry, a method by which all components of the conceptual heat balance equation - metabolic heat production, conduction, radiation, convection, and evaporation - are calculated separately based on fundamental properties of energy exchange. Since partitional calorimetry requires relatively inexpensive equipment (vs. direct calorimetry) and can be used over a wider range of experimental conditions (i.e., different physical activities, laboratory or field settings, clothed or semi-nude), partitional calorimetry allows investigators to address a wide range of problems such as predicting human responses to thermal stress, developing climatic exposure limits and fluid replacement guidelines, estimating clothing properties, evaluating cooling/warming interventions, and identifying potential thermoregulatory dysfunction in unique populations. In this Cores of Reproducibility in Physiology (CORP) review, we summarize the fundamental principles underlying the use of partitional calorimetry, present the various methodological and arithmetic requirements, and provide typical examples of its use. Strategies to minimize estimation error of specific heat balance components, as well the limitations of the method, are also discussed. The goal of the CORP paper is to present a standardized methodology and thus improve the accuracy and reproducibility of research employing partitional calorimetry.

1 September 2011 in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Verified
Journal Article
Closed access
PDF file
OJOllie Jay
Ollie Jay
ABAnthony R. Bain
Anthony R. Bain
TDTomasz M. Deren
Tomasz M. Deren
MSMatthew Sacheli
Matthew Sacheli
MCMatthew N. Cramer
Matthew N. Cramer
The independent influence of peak oxygen uptake (V̇o2 peak) on changes in thermoregulatory responses during exercise in a neutral climate has not been previously isolated because of complex interactions between V̇o2 peak, metabolic heat production (Hprod), body mass, and body surface area (BSA). It was hypothesized that V̇o2 peak does not independently alter changes in core temperature and sweating during exercise. Fourteen males, 7 high (HI) V̇o2 peak: 60.1 ± 4.5 ml·kg−1·min−1; 7 low (LO) V̇o2 peak: 40.3 ± 2.9 ml·kg−1·min−1 matched for body mass (HI: 78.2 ± 6.1 kg; LO: 78.7 ± 7.1 kg) and BSA (HI: 1.97 ± 0.08 m2; LO: 1.94 ± 0.08 m2), cycled for 60-min at 1) a fixed heat production (FHP trial) and 2) a relative exercise intensity of 60% V̇o2 peak (REL trial) at 24.8 ± 0.6°C, 26 ± 10% RH. In the FHP trial, Hprod was similar between the HI (542 ± 38 W, 7.0 ± 0.6 W/kg or 275 ± 25 W/m2) and LO (535 ± 39 W, 6.9 ± 0.9 W/kg or 277 ± 29 W/m2) groups, while changes in rectal (Tre: HI: 0.87 ± 0.15°C, LO: 0.87 ± 0.18°C, P = 1.00) and aural canal (Tau: HI: 0.70 ± 0.12°C, LO: 0.74 ± 0.21°C, P = 0.65) temperature, whole-body sweat loss (WBSL) (HI: 434 ± 80 ml, LO: 440 ± 41 ml; P = 0.86), and steady-state local sweating (LSRback) ( P = 0.40) were all similar despite relative exercise intensity being different (HI: 39.7 ± 4.2%, LO: 57.6 ± 8.0% V̇o2 peak; P = 0.001). At 60% V̇o2 peak, Hprod was greater in the HI (834 ± 77 W, 10.7 ± 1.3 W/kg or 423 ± 44 W/m2) compared with LO (600 ± 90 W, 7.7 ± 1.4 W/kg or 310 ± 50 W/m2) group (all P < 0.001), as were changes in Tre (HI: 1.43 ± 0.28°C, LO: 0.89 ± 0.19°C; P = 0.001) and Tau (HI: 1.11 ± 0.21°C, LO: 0.66 ± 0.14°C; P < 0.001), and WBSL between 0 and 15, 15 and 30, 30 and 45, and 45 and 60 min (all P < 0.01), and LSRback ( P = 0.02). The absolute esophageal temperature (Tes) onset for sudomotor activity was ∼0.3°C lower ( P < 0.05) in the HI group, but the change in Tes from preexercise values before sweating onset was similar between groups. Sudomotor thermosensitivity during exercise were similar in both FHP ( P = 0.22) and REL ( P = 0.77) trials. In conclusion, changes in core temperature and sweating during exercise in a neutral climate are determined by Hprod, mass, and BSA, not V̇o2 peak.

1 November 2015 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
MCMatthew N. Cramer
Matthew N. Cramer
OJOllie Jay
Ollie Jay
Individual variation in the thermoregulatory responses to exercise is notoriously large. Although aerobic fitness (V̇o2 max) and body fatness are traditionally considered important predictors of individual core temperature and sweating responses, recent evidence indicates potentially important and independent roles for biophysical factors. Using stepwise regression, we examined the proportion of individual variability in rectal temperature changes (ΔTre), whole body sweat loss (WBSL), and steady-state local sweat rate (LSRss) independently described by 1) biophysical factors associated with metabolic heat production (Hprod) and evaporative heat balance requirements (Ereq) relative to body size and 2) factors independently related to V̇o2 max and body fatness. In a total of 69 trials, 28 males of wide-ranging morphological traits and V̇o2 max values cycled at workloads corresponding to a range of absolute Hprod (410–898 W) and relative intensities (32.2–82.0% V̇o2 max) for 60 min in 24.8 ± 0.7°C and 33.4 ± 12.2% relative humidity. Hprod (in W/kg total body mass) alone described ∼50% of the variability in ΔTre (adjusted to r2 = 0.496; P < 0.001), whereas surface area-to-mass ratio and body fat percentage (BF%) explained an additional 4.3 and 2.3% of variability, respectively. For WBSL, Ereq (in W) alone explained ∼71% of variance (adjusted to r2 = 0.713, P < 0.001), and the inclusion of BF% explained an additional 1.3%. Similarly, Ereq (in W/m2) correlated significantly with LSRss (adjusted to r2 = 0.603, P < 0.001), whereas %V̇o2 max described an additional ∼4% of total variance. In conclusion, biophysical parameters related to Hprod, Ereq, and body size explain 54–71% of the individual variability in ΔTre, WBSL, and LSRss, and only 1–4% of additional variance is explained by factors related to fitness or fatness.