1 March 2024 in Journal of Instrumentation
TCthe HERD SCD collaboration
the HERD SCD collaboration
The High Energy Cosmic Radiation Detector (HERD) is an experiment designed for direct measurement of cosmic rays on the Chinese Space Station in 2027. Its goals include precise measurements of cosmic ray energy spectra, mass composition, electron/positron spectra, cosmic rays anisotropy, gamma ray astronomy and indirect searches for Dark Matter. HERD features a 55X0, homogeneous, 3D segmented imaging calorimeter and can detect particles from the top and four lateral sides, providing precise energy measurements and electron/proton separation for a wide field of view. A key detector in HERD is the Silicon Charge Detector (SCD). SCD measures the charge of particles before interaction with other materials, minimizing cosmic rays nuclei fragmentation and reducing systematics on nuclei flux measurement. Thorough studies, TCAD and/or SPICE simulations, and accelerator tests on prototypes have been conducted to evaluate the tracking and charge resolution capabilities of the SCD. Further testing with 300 μm detectors is planned in the coming months to fully characterize the SCD's performance. This paper presents the results of the simulation studies and of the measured performance with particles.
1 March 2022 in Journal of Instrumentation
The FOOT (FragmentatiOn Of Target) multi-detector experiment aims at improving the accuracy of oncological hadrontherapy for tumor treatment. It studies the nuclear fragmentation due to the interactions of charged particle beams with patient tissues employing the inverse kinematic approach to boost the fragments in the laboratory reference system. Hence it is necessary a tracking system in a magnetic field to measure the momentum of the charged fragments. The Microstrip Silicon Detector (MSD) is part of the charged-ions-tracking magnetic spectrometer for the evaluation of the Linear Energy Transfer LET (dE/dx) and the nuclear fragments momentum. Here we describe the MSD architecture and its data acquisition system whose task is to collect and digitize the detectors output, generating a data packet to be sent to the experiment’s central acquisition. This data acquisition system is designed and tested to withstand the trigger rate and detector’s throughput; it has a small size and is easily portable, a necessary feature for an experiment that will move among the available ion beam accelerators and proton therapy treatment rooms.
4 September 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
ASTRA-64 (Adaptable Silicon sTrip Read-out ASIC) is a 64-channel mixed-signal ASIC designed for reading out micro-strip silicon detectors. Its initial application is on serving as the read-out for the Silicon Charge Detector of the HERD experiment, slated for installation aboard the Chinese space station in 2027 to facilitate tracking and supplementary charge measurement. Designed using 110 nm technology, ASTRA-64 comprises two identical mirrored blocks, each accommodating 32 channels. Each channel integrates a Charge-Sensitive Amplifier featuring two programmable gain settings suitable for both positive and negative input signal polarities. Following this is a shaper with adjustable peaking time, allowing for noise performance optimization based on the detector capacitance. The front-end gain is calibrated to enable linear charge measurement of up to 160 fC and 80 fC depending on the gain configuration. ASTRA-64 offers two distinct readout modes. In the analog readout mode, sampled voltages are sent off-chip via an analog multiplexer linked with a differential output buffer. Conversely, the digital readout mode employs a Wilkinson ADC in each channel to digitize sampled voltages, with a shared serializer transmitting digital data through an SLVS driver. Additionally, a fast shaper, in tandem with a leading-edge hysteresis discriminator, is integrated, and the outputs of the 32 channel discriminators are merged using a FAST-OR logic to produce a rapid trigger signal off-chip. Remarkably, the ASIC’s power dissipation is kept below 600 W per channel, aligning with stringent power consumption requirements for space applications. We will present the tests, characterization, and performance of ASTRA-64.
29 October 2026 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
22 August 2026 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 September 2026 in Journal of Instrumentation
The Pentadimensional Tracking Space Detector (PTSD) project aims to increase the Technological Readiness Level (TRL) of Low Gain Avalanche Diode (LGAD)-based Si- μ strip trackers for space applications. Originally developed for collider experiments, LGADs provide simultaneous high-precision timing (<100 ps) and spatial (∼ 10 μm) measurements, making them a promising technology for future 5D space tracking systems (position, time, and charge). A major challenge for large-area thin silicon detectors is the high input capacitance seen by the Front-End Electronics (FEE), which increases noise and this could be mitigated only by requiring additional power consumption. The PTSD project addresses this issue through dedicated capacitance-mitigation strategies based on alternative readout architectures. This paper presents the proposed approach together with the first laboratory results. This work also discusses briefly the result of a Concurrent Engineering system-level study for a CubeSat-based LGAD tracking demonstrator. A successful in-orbit validation could raise the TRL of LGAD Si- μ strip trackers to 9, enabling their immediate adoption for the use in future charged cosmic-ray and γ -ray space missions.