Shreya Nag

Shreya Nag

Auto-generated profile, based on publicly available information

Shreya Nag

Department of Electronics and Communication Engineering, University of Engineering and Management, Kolkata, India

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SNShreya Nag
Shreya Nag
SPSusmita Pradhan
Susmita Pradhan
HNHemanta Naskar
Hemanta Naskar
RRRunu Banerjee Roy
Runu Banerjee Roy
BTBipan Tudu
Bipan Tudu
RBRajib Bandyopadhay
Rajib Bandyopadhay
In this present work, electrochemical detection and quantification of formalin (FAL) trace present in mushroom (Agaricus bisporus) was premeditated using a cerium oxide nanoparticle modified graphite paste electrode (CeO2@GP). Cerium oxide (CeO2) nanoparticles (nps) were synthesized through the sol-gel technique from cerium nitrate hexahydrate using poly (ethylene glycol) as a capping agent. The prepared CeO2 nps were characterized using X-ray diffraction (XRD) and transmission electron microscopy (TEM) techniques which revealed the successful formation of the cubic phase of CeO2 having crystallite size 4.84 nm. The prepared CeO2 nps were used to modify the graphite paste electrode (bare GP). Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were utilized to study comparative electroanalytical features of the fabricated electrodes. Under optimized experimental conditions, CeO2@GP exhibited a wide linear range from 25μM-1mM and a limit of detection of 1μM. Moreover, CeO2@GP featured high repeatability, reproducibility, and long-term stability. The electrode exhibited high selectivity for FAL in the presence of interferences like ethanol, methanol, formic acid, benzaldehyde, and acetone. CeO2@GP demonstrated exceptional aptitudes in electrochemical behavior when subjected to mushroom extract.

16 November 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SNShreya Nag
Shreya Nag
SPSusmita Pradhan
Susmita Pradhan
DDDebangana Das
Debangana Das
BTBipan Tudu
Bipan Tudu
RBRajib Bandyopadhay
Rajib Bandyopadhay
RRRunu Banerjee Roy
Runu Banerjee Roy
Formalin is extensively used by traders to preserve various food items like fish and mushrooms, but it has serious health hazards. Detection of formalin content in foods is a challenging problem and in the proposed work, an electrochemical sensor based on a molecular imprinted polymer of acrylonitrile over graphite platform (MiPAN@GP electrode) is pioneered for the recognition of formalin (FAL). The synthesized MiPAN@GP electrode material was characterized with Fourier transform infra-red (FTIR) spectroscope, UV-visible (UV-vis) spectroscope, and scanning electron microscope (SEM). The analytical performance of the electrode was evaluated by a three electrode system using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). A wide linear range from $10 \mu \text{M}$ to $1000 \mu \text{M}$ with a limit of detection of $0.63 \mu \text{M}$ was obtained. The MiPAN@GP sensor exhibited various advantages, such as low cost, high repeatability, high reproducibility, long term stability, and good selectivity. The practical applicability of the MiPAN@GP electrode was tested with mushroom and fish extracts which yielded satisfactory results and high accuracy ( $\approx 99$ %) when compared with the high performance liquid chromatography (HPLC) analysis results.

6 June 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SNShreya Nag
Shreya Nag
DDDebangana Das
Debangana Das
HNHemanta Naskar
Hemanta Naskar
BTBipan Tudu
Bipan Tudu
RBRajib Bandyopadhay
Rajib Bandyopadhay
RRRunu Banerjee Roy
Runu Banerjee Roy
A nickel cobalt oxide nanoparticle modified graphite paste electrode (NiCo2O4@GP) was developed to detect and quantify metanil yellow traces (MY) present in food particles and is presented in this paper. Nanoparticles of nickel cobalt oxide (NiCo2O4) were characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis revealing 18.75 nm crystallite size and these nanoparticles were used to modify a graphite paste electrode. The performance of the fabricated electrodes was studied using differential pulse voltammetry (DPV) and cyclic voltammetry (CV). NiCo2O4@GP displayed a wide linear range of 5 to 1000 μM and a limit of detection of 100 nM under optimal experimental conditions. Additionally, NiCo2O4@GP was highly repeatable, reproducible, and stable over time. Despite interferences such as sodium, potassium, zinc ions, and curcumin, the NiCo2O4@GP electrode was observed to be highly selective for MY. When exposed to real turmeric powder samples, NiCo2O4@GP exhibited remarkable electrochemical behavior.

22 October 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DDDebangana Das
Debangana Das
SNShreya Nag
Shreya Nag
SDShubham De
Shubham De
AHAjanto Kumar Hazarika
Ajanto Kumar Hazarika
SSSantanu Sabhapondit
Santanu Sabhapondit
RRRunu Banerjee Roy
Runu Banerjee Roy
The current study utilizes molecularly imprinted polymer (MIP) technology to fabricate a cost-effective and reproducible electrode for selective determination and quantitative prediction of epicatechin (EC) in green tea. Acrylamide (AAm) co-polymerized with ethylene glycol dimethacrylate (EGDMA) and optically inactive quercetin (Q) as the template has been used to make the MIP-Q@G material. The voltammetric experiment has been performed using the MIP-Q@G electrode with the help of a three-electrode configuration. In addition to a low detection limit (LoD) of $0.33 ~\mu \text{M}$ , the electrode exhibited two wide ranges of linearity from $1 ~\mu \text{M}$ – $100 ~\mu \text{M}$ and $100 ~\mu \text{M}$ to $500 ~\mu \text{M}$ . The limit of quantitation (LoQ) of the electrode was found to be $1.09 ~\mu \text{M}$ . Partial least square regression (PLSR) and principal component regression (PCR) models have been developed to investigate the predictive ability of the MIP-Q@G electrode using the differential pulse voltammetry (DPV) signals and the high- performance liquid chromatography (HPLC) data. Both PLSR and PCR models achieved prediction accuracies of 94.54 % and 94.41% with a root mean square error of calibration (RMSEC) of 0.113 and 0.119, respectively.

2 February 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MMMadhurima Moulick
Madhurima Moulick
DDDebangana Das
Debangana Das
SNShreya Nag
Shreya Nag
BTBipan Tudu
Bipan Tudu
RBRajib Bandyopadhay
Rajib Bandyopadhay
RRRunu Banerjee Roy
Runu Banerjee Roy
The present study aims at developing a low-cost and reliable electrode based on the molecularly imprinted polymer (MIP) technology for the detection and quantification of tannic acid (TAN) in black tea samples. The material was synthesized using a copolymer of acrylic acid (AA) and ethylene glycol dimethacrylate (EGDMA), a cross-linker, on a graphite bed. The developed electrode material was characterized by UV-Visible (UV-Vis) spectroscopy and scanning electron microscope (SEM). The performance of the electrode was evaluated by a three-electrode configuration using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The devised electrode (MIP_TAN) has shown a wide linear range of performance from 0.1 to 500 μM with a limit of detection (LOD) of 37nM and evinced high repeatability, reproducibility, stability, and good selectivity. To predict the content of TAN, partial least square regression model (PLSR) was developed utilizing DPV responses of the electrode and high-performance liquid chromatography (HPLC) as reference data. The prediction accuracy of PLSR was obtained as 96.315%. The electrode was examined on real samples of black tea which produced satisfactory results.

13 January 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SNShreya Nag
Shreya Nag
DDDebangana Das
Debangana Das
RRRunu Banerjee Roy
Runu Banerjee Roy
The proposed work, reflects a polyacrylamide with molecular imprints over graphite substrate (MIPAM/GP electrochemical sensor) fabricated to detect the flavoring element vanillin (VNL). The synthesized material has been characterized with scanning electron microscope (SEM), Fourier transform infra-red (FTIR) spectroscope, and UV-visible (UV-vis) spectroscope. A three-electrode arrangement has been used to evaluate the electrode’s analytical performance using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The electrode featured wide linearity range 0.1 μM to 1000 μM in addition the limit of detection of 1.43 nM. The fabricated sensor demonstrated excellent repeatability, reproducibility, selectivity at low cost with long term stability. The practical application of the MIPAM/GP electrode was assessed using various dessert extracts like icecream, yogurt, custard, milkshake, and the results were promising when compared to the HPLC study.