1 December 2011 in Digital Signal Processing
23 February 2021 in International Journal of Communication Systems
1 November 2020 in Journal of the Optical Society of America A
NENirmeen A. El-Bahnasawy
A contact-free inexpensive measurement system with an algorithm based on the integral form of video frames is proposed to estimate the respiration rate from an extracted respiration pattern. The proposed algorithm is applied and tested on 28 videos of sleeping-simulated positions, and the results are compared with the manual visual inspection values. With linear regression, the determination coefficient (R-2) is 0.961, which demonstrates high agreement with reference measurements. In addition, the Bland-Altman plot shows that almost all data points are within the 95% limits of agreement. Moreover, the time complexity of the proposed algorithm, which involves taking just a single point value of the integral image, is lower than that of traditional methods that circulate over a large number of points. In other words, the proposed algorithm achieves O(1) fixed-time complexity compared to O(N-2) for traditional methods. The average speed of processing is enhanced by about 17.4%. (C) 2020 Optical Society of America
25 July 2023 in Complex & Intelligent Systems
Security of Internet-of-Medical-Things (IoMT) networks has evolved as a vital issue in recent years. The IoMT networks are designed to link patients with caregivers. All reports, data, and medical signals are transferred over these networks. Hence, these networks require robust and secure access strategies for patients to send their vital data or reports. Hence, hacking of these networks may lead to harmful effects on patients. One of the vulnerable points to hacking in these networks is the access point. Access to these networks could be performed with biometrics. The popular biometric traits for this purpose are biomedical signals such as Electrocardiogram (ECG) signals, as they are continuously monitored and measured for patients. A common thread between all biometric authentication systems is the possibility of losing the biometric traits forever if hacking attempts manage to concur the biometric template storage. A new trend in the field of biometric authentication is to avoid the utilization of original biometrics in access control processes. A possible alternative is to use cancelable biometrics instead. Cancelable biometrics can be generated through encryption schemes or non-invertible transforms. This paper adopts both strategies in a unified framework for cancelable ECG signal recognition that can be used in the access step of IoMT networks. The proposed framework begins with applying a non-invertible transformation on the ECG signals through fuzzy logic to change the dynamic range of the signals. As this process is non-invertible in nature, it prevents the recovery of the original ECG signals from the processed versions, which is the main target of cancelable biometric systems. After that, lightweight encryption through XOR operation with user-specific patterns is implemented. Here, the high complexity of full encryption schemes that need a large processing burden is eliminated. The addition of the encryption stage enhances the security of cancelable biometric traits, allowing a hybrid nature of the proposed cancelable biometric framework through the merging of non-invertible transforms and encryption algorithms. Moreover, an FPGA hardware implementation is introduced for real implementation of the proposed ECG-based cancelable biometric recognition framework. This hardware can accompany the user to allow access of the IoMT network when requested. Experimental results show a promising performance of the proposed framework with a large Area under the Receiver Operating Characteristic curve (AROC) of 99.5% and an Equal Error Rate (EER) of 0.058%.
20 December 2018 in Multimedia Tools and Applications
1 February 2024 in Neural Computing and Applications