Todd Kuiken

Todd Kuiken

Auto-generated profile, based on publicly available information

Todd Kuiken

Genetic Engineering and Society Center, North Carolina State University, Raleigh, USA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2015 in Beilstein Journal of Nanotechnology
Verified
Journal Article
Open access
PDF file
MVMarina Vance
Marina Vance
TKTodd Kuiken
Todd Kuiken
EVEric P. Vejerano
Eric P. Vejerano
SMSean P. McGinnis
Sean P. McGinnis
MHMichael F Hochella
Michael F Hochella
MHMatthew S. Hull
Matthew S. Hull
To document the marketing and distribution of nano-enabled products into the commercial marketplace, the Woodrow Wilson International Center for Scholars and the Project on Emerging Nanotechnologies created the Nanotechnology Consumer Products Inventory (CPI) in 2005. The objective of this present work is to redevelop the CPI by leading a research effort to increase the usefulness and reliability of this inventory. We created eight new descriptors for consumer products, including information pertaining to the nanomaterials contained in each product. The project was motivated by the recognition that a diverse group of stakeholders from academia, industry, and state/federal government had become highly dependent on the inventory as an important resource and bellweather of the pervasiveness of nanotechnology in society. We interviewed 68 nanotechnology experts to assess key information needs. Their answers guided inventory modifications by providing a clear conceptual framework best suited for user expectations. The revised inventory was released in October 2013. It currently lists 1814 consumer products from 622 companies in 32 countries. The Health and Fitness category contains the most products (762, or 42% of the total). Silver is the most frequently used nanomaterial (435 products, or 24%); however, 49% of the products (889) included in the CPI do not provide the composition of the nanomaterial used in them. About 29% of the CPI (528 products) contain nanomaterials suspended in a variety of liquid media and dermal contact is the most likely exposure scenario from their use. The majority (1288 products, or 71%) of the products do not present enough supporting information to corroborate the claim that nanomaterials are used. The modified CPI has enabled crowdsourcing capabilities, which allow users to suggest edits to any entry and permits researchers to upload new findings ranging from human and environmental exposure data to complete life cycle assessments. There are inherent limitations to this type of database, but these modifications to the inventory addressed the majority of criticisms raised in published literature and in surveys of nanotechnology stakeholders and experts. The development of standardized methods and metrics for nanomaterial characterization and labelling in consumer products can lead to greater understanding between the key stakeholders in nanotechnology, especially consumers, researchers, regulators, and industry.

11 February 2009 in JAMA
Verified
Journal Article
Open access
PDF file
TKTodd A. Kuiken
Todd A. Kuiken
GLGuanglin Li
Guanglin Li
BLBlair A. Lock
Blair A. Lock
RLRobert D. Lipschutz
Robert D. Lipschutz
LMLaura A. Miller
Laura A. Miller
KEKevin B. Englehart
Kevin B. Englehart
The loss of one or both arms is a major disability that profoundly limits the everyday capabilities and interactions of individuals with upper-limb amputation. Currently available prostheses do not adequately restore the function of an individual's arm and hand. The most commonly used prostheses are body-powered. These devices capture remaining shoulder motion with a harness and transfer this movement through a cable to operate the hand, wrist, or elbow. With this control method, only 1 joint can be operated at a time. Myoelectric prostheses use the electromyogram (EMG) signals (the electrical signals generated during muscle contraction) from residual limb muscles to control motorized arm joints.

1 December 2009 in Environmental Health Perspectives
Verified
Journal Article
Open access
BKBarbara Karn
Barbara Karn
TKTodd Kuiken
Todd Kuiken
MOMartha Otto
Martha Otto
A peer-reviewed open access journal published by the National Institute of Environmental Health Sciences

21 May 2010 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
DTDennis Tkach
Dennis Tkach
HHHe Huang
He Huang
TKTodd A Kuiken
Todd A Kuiken
Background: Significant progress has been made towards the clinical application of human-machine interfaces (HMIs) based on electromyographic (EMG) pattern recognition for various rehabilitation purposes. Making this technology practical and available to patients with motor deficits requires overcoming real-world challenges, such as physical and physiological changes, that result in variations in EMG signals and systems that are unreliable for long-term use. In this study, we aimed to address these challenges by (1) investigating the stability of time-domain EMG features during changes in the EMG signals and (2) identifying the feature sets that would provide the most robust EMG pattern recognition. Methods: Variations in EMG signals were introduced during physical experiments. We identified three disturbances that commonly affect EMG signals: EMG electrode location shift, variation in muscle contraction effort, and muscle fatigue. The impact of these disturbances on individual features and combined feature sets was quantified by changes in classification performance. The robustness of feature sets was evaluated by a stability index developed in this study. Results: Muscle fatigue had the smallest effect on the studied EMG features, while electrode location shift and varying effort level significantly reduced the classification accuracy for most of the features. Under these disturbances, the most stable EMG feature set with combination of four features produced at least 16.0% higher classification accuracy than the least stable set. EMG autoregression coefficients and cepstrum coefficients showed the most robust classification performance of all studied time-domain features. Conclusions: Selecting appropriate EMG feature combinations can overcome the impact of the studied disturbances on EMG pattern classification to a certain extent; however, this simple solution is still inadequate. Stabilizing electrode contact locations and developing effective classifier training strategies are suggested to further improve the robustness of HMIs based on EMG pattern recognition.

30 December 2010 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
LSLauren H. Smith
Lauren H. Smith
LHLevi J. Hargrove
Levi J. Hargrove
BLBlair A. Lock
Blair A. Lock
TKTodd A. Kuiken
Todd A. Kuiken
Pattern recognition-based control of myoelectric prostheses has shown great promise in research environments, but has not been optimized for use in a clinical setting. To explore the relationship between classification error, controller delay, and real-time controllability, 13 able-bodied subjects were trained to operate a virtual upper-limb prosthesis using pattern recognition of electromyogram (EMG) signals. Classification error and controller delay were varied by training different classifiers with a variety of analysis window lengths ranging from 50 to 550 ms and either two or four EMG input channels. Offline analysis showed that classification error decreased with longer window lengths ( p <; 0.01). Real-time controllability was evaluated with the target achievement control (TAC) test, which prompted users to maneuver the virtual prosthesis into various target postures. The results indicated that user performance improved with lower classification error ( p <; 0.01 ) and was reduced with longer controller delay ( p <; 0.01), as determined by the window length. Therefore, both of these effects should be considered when choosing a window length; it may be beneficial to increase the window length if this results in a reduced classification error, despite the corresponding increase in controller delay. For the system employed in this study, the optimal window length was found to be between 150 and 250 ms , which is within acceptable controller delays for conventional multistate amplitude controllers.

1 February 2007 in The Lancet
Verified
Journal Article
Closed access
TKTodd A Kuiken
Todd A Kuiken
LMLaura A Miller
Laura A Miller
RLRobert D Lipschutz
Robert D Lipschutz
BLBlair A Lock
Blair A Lock
KSKathy Stubblefield
Kathy Stubblefield
GDGregory A Dumanian
Gregory A Dumanian