26 May 2022 in Renewable and Sustainable Energy Reviews
4 February 2022 in IEEE Transactions on Smart Grid
Heat pumps (HPs) can provide flexibility for different power system services, including frequency support. The modern power system integrates various sized HPs as part of individual or district heating systems. While the basic principles and layout are similar for differently sized HPs, differences in dynamic response characteristics entail different limitations on their participation in grid service provision. Small-scale HPs (S-HPs) have a fast response and are widely distributed, while large-scale HPs (L-HPs) are more centralized with slow dynamics. This paper propose an innovative and coordinated control scheme for primary frequency response from S-HPs and L-HPs. The method configures the control of S-HPs based on an observed homogeneous S-HP population response to control actions. Furthermore, a centralized optimization of L-HPs based on model predictive control (MPC), balances the S-HP population’s response. Analysis of simulation results evaluates and compares the proposed methodology against exiting methods that consider only S-HP units. Results show the significant improvement of the frequency nadir with the support from the heating system through the proposed method.
5 September 2018 in Journal of Modern Power Systems and Clean Energy
In the modern power system, both local and centralized reactive power control strategies for photovoltaic (PV) plants, are proposed and compared. While local control improves the network security, it lacks the optimization benefits from centralized control strategies. Therefore, this paper considers the coordination of the two control strategies, depending on external impact from the weather system and consumer behavior, in a low voltage (LV) distribution feeder. Through modeling and simulation in an established real-time cyber-physical simulation platform, the LV network is evaluated with both local and centralized control. A set of boundaries for coordinating between the two strategies are identified, which can help network operators in deciding suitable control in different operating situations. Furthermore, the cyber-physical simulation platform, is used to study the impact of physical perturbations, i.e. changes in irradiance and consumption, and cyber disturbances, in form of communication channel noise, is evaluated for the control strategies. Results show how small and large disturbances in the cyber system affects the centralized control strategy optimizer performance.
1 December 2019 in International Journal of Electrical Power & Energy Systems