Charles Alexander McKenzie

Charles Alexander McKenzie

Auto-generated profile, based on publicly available information

Charles Alexander McKenzie

Department of Medical Biophysics, Western University, London, ON, Canada

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2008 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
HYHuanzhou Yu
Huanzhou Yu
ASAnn Shimakawa
Ann Shimakawa
CMCharles A. McKenzie
Charles A. McKenzie
EBEthan Brodsky
Ethan Brodsky
JBJean H. Brittain
Jean H. Brittain
SRScott B. Reeder
Scott B. Reeder
Multiecho chemical shift–based water‐fat separation methods are seeing increasing clinical use due to their ability to estimate and correct for field inhomogeneities. Previous chemical shift‐based water‐fat separation methods used a relatively simple signal model that assumes both water and fat have a single resonant frequency. However, it is well known that fat has several spectral peaks. This inaccuracy in the signal model results in two undesired effects. First, water and fat are incompletely separated. Second, methods designed to estimate T in the presence of fat incorrectly estimate the T decay in tissues containing fat. In this work, a more accurate multifrequency model of fat is included in the iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL) water‐fat separation and simultaneous T estimation techniques. The fat spectrum can be assumed to be constant in all subjects and measured a priori using MR spectroscopy. Alternatively, the fat spectrum can be estimated directly from the data using novel spectrum self‐calibration algorithms. The improvement in water‐fat separation and T estimation is demonstrated in a variety of in vivo applications, including knee, ankle, spine, breast, and abdominal scans. Magn Reson Med 60:1122–1134, 2008.

24 July 2007 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CLChia‐Ying Liu
Chia‐Ying Liu
CMCharles A. McKenzie
Charles A. McKenzie
HYHuanzhou Yu
Huanzhou Yu
JBJean H. Brittain
Jean H. Brittain
SRScott B. Reeder
Scott B. Reeder
Quantification of hepatic steatosis is a significant unmet need for the diagnosis and treatment of patients with nonalcoholic fatty liver disease (NAFLD). MRI is capable of separating water and fat signals in order to quantify fatty infiltration of the liver (hepatic steatosis). Unfortunately, fat signal has confounding T1 effects and the nonzero mean noise in low signal‐to‐noise ratio (SNR) magnitude images can lead to incorrect estimation of the true lipid percentage. In this study, the effects of bias from T1 effects and image noise were investigated. An oil/water phantom with volume fat‐fractions ranging linearly from 0% to 100% was designed and validated using a spoiled gradient echo (SPGR) sequence in combination with a chemical‐shift based fat‐water separation method known as iterative decomposition of water and fat with echo asymmetry and least squares estimation (IDEAL). We demonstrated two approaches to reduce the effects of T1: small flip angle (flip angle) and dual flip angle methods. Both methods were shown to effectively minimize deviation of the measured fat‐fraction from its true value. We also demonstrated two methods to reduce noise bias: magnitude discrimination and phase‐constrained reconstruction. Both methods were shown to reduce this noise bias effectively from 15% to less than 1%. Magn Reson Med 58:354–364, 2007.

24 September 2008 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
PRPhilip M. Robson
Philip M. Robson
AGAaron K. Grant
Aaron K. Grant
AMAnanth J. Madhuranthakam
Ananth J. Madhuranthakam
RLRiccardo Lattanzi
Riccardo Lattanzi
DSDaniel K. Sodickson
Daniel K. Sodickson
CMCharles A. McKenzie
Charles A. McKenzie
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g‐factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal‐to‐noise ratio and g‐factor and is demonstrated for SENSE and GRAPPA reconstructions for accelerated acquisitions that have not previously been amenable to such assessment. Only a simple “prescan” measurement of noise amplitude and correlation in the phased‐array receiver, and a single accelerated image acquisition are required, allowing robust assessment of signal‐to‐noise ratio and g‐factor. The “pseudo multiple replica” method has been rigorously validated in phantoms and in vivo, showing excellent agreement with true multiple replica and analytical methods. This method is universally applicable to the parallel imaging reconstruction techniques used in clinical applications and will allow pixel‐by‐pixel image noise measurements for all parallel imaging strategies, allowing quantitative comparison between arbitrary k‐space trajectories, image reconstruction, or noise conditioning techniques. Magn Reson Med 60:895–907, 2008.

25 September 2007 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
HYHuanzhou Yu
Huanzhou Yu
CMCharles A. McKenzie
Charles A. McKenzie
ASAnn Shimakawa
Ann Shimakawa
AVAnthony T. Vu
Anthony T. Vu
ABAnja C.S. Brau
Anja C.S. Brau
SRScott B. Reeder
Scott B. Reeder
Purpose: To describe and demonstrate the feasibility of a novel multiecho reconstruction technique that achieves simultaneous water‐fat decomposition and T2* estimation. The method removes interference of water‐fat separation with iron‐induced T2* effects and therefore has potential for the simultaneous characterization of hepatic steatosis (fatty infiltration) and iron overload.Materials and Methods: The algorithm called “T2*‐IDEAL” is based on the IDEAL water‐fat decomposition method. A novel “complex field map” construct is used to estimate both R2* (1/T2*) and local B0 field inhomogeneities using an iterative least‐squares estimation method. Water and fat are then decomposed from source images that are corrected for both T2* and B0 field inhomogeneity.Results: It was found that a six‐echo multiecho acquisition using the shortest possible echo times achieves an excellent balance of short scan and reliable R2* measurement. Phantom experiments demonstrate the feasibility with high accuracy in R2* measurement. Promising preliminary in vivo results are also shown.Conclusion: The T2*‐IDEAL technique has potential applications in imaging of diffuse liver disease for evaluation of both hepatic steatosis and iron overload in a single breath‐hold. J. Magn. Reson. Imaging 2007;26:1153–1161.

1 March 2011 in Radiology
Verified
Journal Article
Closed access
SMSina Meisamy
Sina Meisamy
CHCatherine D. G. Hines
Catherine D. G. Hines
GHGavin Hamilton
Gavin Hamilton
CSClaude B. Sirlin
Claude B. Sirlin
CMCharles A. McKenzie
Charles A. McKenzie
SRScott B. Reeder
Scott B. Reeder
This work demonstrated that T1-independent chemical shift–based water-fat separation MR imaging with T2* correction, spectral modeling of fat, and eddy current correction is statistically equivalen... PurposeTo prospectively compare an investigational version of a complex-based chemical shift–based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of...

26 February 2007 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
SRScott B. Reeder
Scott B. Reeder
CMCharles A. McKenzie
Charles A. McKenzie
APAngel R. Pineda
Angel R. Pineda
HYHuanzhou Yu
Huanzhou Yu
ASAnn Shimakawa
Ann Shimakawa
JBJean H. Brittain
Jean H. Brittain