Antony J. Hodgson

Antony J. Hodgson

Auto-generated profile, based on publicly available information

Antony J. Hodgson

Department of Mechanical Engineering, Faculty of Applied Science University of British Columbia Vancouver British Columbia Canada

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2018 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
HEHooman Esfandiari
Hooman Esfandiari
RNRobyn Newell
Robyn Newell
CACarolyn Anglin
Carolyn Anglin
JSJohn Street
John Street
AHAntony J. Hodgson
Antony J. Hodgson

12 November 2018 in IEEE/ACM Transactions on Audio, Speech, and Language Processing
Verified
Journal Article
Closed access
VZVahid Zakeri
Vahid Zakeri
AHAntony J. Hodgson
Antony J. Hodgson
Our purpose was to assess if bone drilling sounds could be used to automatically distinguish between hard and soft bone tissues. Such a capability could be of value in a variety of surgical procedures involving drilling through bone. We acquired sound signals from six bovine tibial bones that were being drilled with a surgical drill. We investigated various classifiers including logistic regression, support vector machine (SVM), random forest (RF), and hidden Markov model. We explored different time and frequency features, and considered two training/testing scenarios: leave one bone out (LOBO) and bone-specific (BSP). Moreover, we conducted a survey of practicing surgeons to provide a baseline measure for assessing whether our proposed algorithm could improve the ability of surgeons to identify hard and soft bone tissues based on drilling sounds. The average accuracies for LOBO and BSP were 79.1% and 84.3% respectively. In both scenarios, the feature that resulted in the highest accuracy of classification was wavelet packet transform coefficients. Moreover, RF and SVM produced the highest accuracies for LOBO and BSP, respectively. In the survey, the surgeons were unsure on 29.2% of questions, and had an average accuracy of 51.4% on their judged answers. In conclusion, the drilling in hard and soft bones could be automatically identified with good accuracy based on the drilling sounds. Several of the algorithms tested were generalizable across specimens and their accuracy significantly exceeded surgeons' performance. The significance is that these algorithms can potentially be used to reduce challenges associated with bone drilling procedures.

1 July 2007 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
AHA Hodgson
A Hodgson
NHN Helmy
N Helmy
BMB A Masri
B A Masri
NGN V Greidanus
N V Greidanus
KIK B Inkpen
K B Inkpen
CAC Anglin
C Anglin
The orientation of the femoral component in hip resurfacing arthroplasty affects the likelihood of loosening and fracture. Computer-assisted surgery has been shown to improve significantly the surgeon's ability to achieve a desired position and orientation; nevertheless, both bias and variability in positioning remain and can potentially be improved. The authors recently developed a computer-assisted surgical (CAS) technique to guide the placement of the pin used in femoral head resurfacing arthroplasty and showed that it produced significantly less variation than a typical manual technique in varus/valgus placement relative to a pre-operatively determined surgical plan while taking a comparable amount of time. In the present study, the repeatability of both the CAS and manual techniques is evaluated in order to estimate the relative contributions to overall variability of surgical technique (CAS versus manual), surgeon experience (novice versus experienced), and other sources of variability (e.g. across specimens and across surgeons). This will enable further improvements in the accuracy of CAS techniques. Three residents/fellows new to femoral head resurfacing and three experienced hip arthroplasty surgeons performed 20-30 repetitions of each of the CAS and manual techniques on at least one of four cadaveric femur specimens. The CAS system had markedly better repeatability (1.2°) in varus/valgus placement relative to the manual technique (2.8°), slightly worse repeatability in version (4.4° versus 3.2°), markedly better repeatability in mid-neck placement (0.7 mm versus 2.5 mm), no significant dependence on surgeon skill level (in contrast to the manual technique), and took significantly less time (50 s versus 123 s). Proposed improvements to the version measurement process showed potential for reducing the standard deviation by almost two thirds. This study supports the use of CAS for femoral head resurfacing as it is quicker than the manual technique, independent of surgeon experience, and demonstrates improved repeatability.

8 September 2022 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
MHMatthew D. Beng Hickey
Matthew D. Beng Hickey
BMBassam A. Masri
Bassam A. Masri
AHAntony J. Hodgson
Antony J. Hodgson
Background: Robotic, navigated, and patient-specific instrumentation (PSI) TKA procedures have been introduced to improve component placement precision and improve implant survivorship and other clinical outcomes. However, the best available evidence has shown that these technologies are ineffective in reducing revision rates in the general TKA patient population. Nonetheless, it seems plausible that these technologies could be an effective and cost-effective means of reducing revision risk in clinical populations that are at an elevated risk of revision because of patient-specific demographics (such as older age at index surgery, elevated BMI, and being a man). Since clinical trials on this topic would need to be very large, a simulation approach could provide insight on which clinical populations would be the most promising for analysis. Questions/purposes: We conducted a simulation-based analysis and asked: (1) Given key demographic parameters characterizing a patient population, together with estimates of the precision achievable with selected forms of technology assistance in TKA, can we estimate the expected distributions of anticipated reductions in lifetime revision risk for that population and the associated improvements in quality-adjusted life years (QALYs) that would be expected to result? (2) Are there realistic practice characteristics (such as combinations of local patient demographics and capital and per-procedure costs) for which applying a per-patient risk-prioritized policy for using technology-assisted TKA could be considered cost-effective based on projected cost savings from reductions in revision rates? Methods: We designed simulations of hypothetical practice-specific clinical scenarios, each characterized by patient volume, patient demographics, and technology-assisted surgical technique, using demographic information drawn from other studies to characterize two contrasting simulated clinical scenarios in which the distributions of factors describing patients undergoing TKA place one population at a comparatively elevated risk of revision (elevated-risk population) and the second at a comparatively reduced risk of revision (lower-risk population). We used results from previous systematic reviews and meta-analyses to estimate the implant precision in coronal plane alignment for patient-specific instrumentation, navigated, and robotic technology. We generated simulated TKA patient populations based on risk estimates from large clinical studies, structured reviews, and meta-analyses and calculated the patient-specific reduction in the revision risk and the change in QALYs attributable to the technology-assisted intervention in each of the two simulated clinical scenarios. We also incorporated a sensitivity analysis, incorporating variations in the effect size of deviations from overall coronal alignment on revision risk and difference in health state utilities acquired through a structured review process. We then simulated the outcomes of 25,000 operations per patient using the precisions associated with the conventional TKA technique, the three technology-assisted techniques, and a hypothetical technology-assisted intervention that could consistently deliver perfectly neutral overall coronal alignment, which is unachievable in practice. A risk-prioritized treatment policy was emulated by ordering the simulated patients from the highest to lowest predicted increase in QALYs, such that simulated patients who would see the greatest increase in the QALYs (and therefore the greatest reduction in lifetime revision risk) were the patients to receive technology-assisted TKA intervention in a practice. We used cost estimates acquired through a structured review process and calculated the net added costs of each of the three technology-assisted techniques as a function of the percent utilization (proportion of patients treated with technology assistance in a practice), factoring in fixed costs, per-procedure variable costs, and savings occurring from the prevention of future revision surgery. Finally, we calculated the incremental cost-effectiveness ratio (ICER) and marginal cost-effectiveness ratio (MCER) for each technology-assisted technique for the two clinical scenarios. We then used a Monte Carlo approach to simulate variations in key patient risk, health state, and economic factors as well as to obtain a distribution of estimates for cost-effectiveness. We considered an intervention to be cost effective if either the ICER or MCER values were below USD/QALY 63,000. Results: For the lower-risk population, the median reduction in the revision risk was 0.9% (0.4% to 2.2%, extrema from the sensitivity analysis) and 1.8% (0.9% to 4.4%) for PSI and robotic TKA, respectively, and 1.9% (1.0% to 4.6%) for ideal TKA. In contrast, the median reduction in the revision risk in the elevated-risk clinical scenario was 2.0% (1.2% to 3.4%) and 4.6% (2.7% to 8.5%) for PSI and robotic TKA and 5.1% (3.0% to 9.4%) for ideal TKA. Estimated differences in the cumulative gain in QALYs attributable to technology-assisted TKA ranged from 0.6 (0.2 to 1.8) to 4.0 (1.8 to 10.0) QALYs per 100 patients, depending on the intervention type and clinical scenario. For PSI, we found treating 15% of patients in the lower-risk population and 77% in the elevated-risk population could meet the threshold for being considered cost effective. For navigated TKA systems offering high alignment precision, we found the intervention could meet this threshold for practice sizes of at least 300 patients per year and a percent utilization of 27% in the lower-risk population. In the elevated-risk population, cost-effectiveness could be achieved in practice volumes as small as 100 patients per year with a percent utilization of at least 6%, and cost savings could be achieved with a percent utilization of at least 45%. We found that robotic TKA could only meet the threshold for being considered cost-effectiveness in...

23 September 2023 in Ultrasonics
Verified
Journal Article
Closed access
AOAmirhossein Omidvar
Amirhossein Omidvar
RRRobert Rohling
Robert Rohling
Edmond CretuEdmond Cretu
Edmond Cretu
MCMark Cresswell
Mark Cresswell
AHAntony J Hodgson
Antony J Hodgson

18 January 2021 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
HEHooman Esfandiari
Hooman Esfandiari
SWSimon Weidert
Simon Weidert
IKIstván Kövesházi
István Kövesházi
CACarolyn Anglin
Carolyn Anglin
JSJohn Street
John Street
AHAntony J. Hodgson
Antony J. Hodgson