Kyung Eun Song

Kyung Eun Song

Auto-generated profile, based on publicly available information

Kyung Eun Song

Department of Clinical Pathology, Kyungpook National University School of Medicine, Daegu, Korea

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Annals of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
EYEun-Hyung Yoo
Eun-Hyung Yoo
SCSoon Hee Chang
Soon Hee Chang
DSDo-Young Song
Do-Young Song
CLChae Hoon Lee
Chae Hoon Lee
GCGyu Young Cheong
Gyu Young Cheong
KSKyung Eun Song
Kyung Eun Song
Eun-Hyung Yoo, M.D., Ph.D., Soon Hee Chang, M.D., Ph.D., Do-Young Song, M.D., Ph.D., Chae Hoon Lee, M.D., Ph.D., Gyu Young Cheong, M.D., Ph.D., Sunggyun Park, M.D., Ph.D., Jae Hee Lee, M.D., Ph.D., Sooin Lee, M.D., Ph.D., Sang-Gyu Kwak, Ph.D., Chang-Ho Jeon, M.D., Ph.D., and Kyung Eun Song, M.D., Ph.D.. Ann Lab Med 2022;42:24-35. https://doi.org/10.3343/alm.2022.42.1.24

16 March 2016 in Scandinavian Journal of Clinical and Laboratory Investigation
Verified
Journal Article
Closed access
PDF file
JHJi Yeon Ham
Ji Yeon Ham
HJHee-Yeon Jung
Hee-Yeon Jung
JCJi-Young Choi
Ji-Young Choi
SPSun-Hee Park
Sun-Hee Park
YKYong-Lim Kim
Yong-Lim Kim
Jang-Hee ChoJang-Hee Cho
Jang-Hee Cho
Background Therapeutic drug monitoring of mycophenolic acid (MPA) is required to optimize the immunosuppressive effect and minimize toxicity. We validated a new particle-enhanced turbidimetric inhibition immunoassay (PETINIA) for the determination of MPA levels and evaluated the relationship of MPA trough level with drug-related adverse events. Methods PETENIA and liquid chromatography-mass spectrometry (LC-MS) were used to determine MPA concentrations from 54 kidney transplant recipients (KTRs). Agreement between PETINIA and LC-MS results was assessed by Passing-Bablok regression and the Bland-Altman plot method. The association of adverse events with MPA trough level obtained by PETINIA was analyzed. Results PETINIA revealed a good agreement with the LC-MS; Regression analysis gave an equation of y = 1.27x − 0.12 (r2 = 0.975, p < 0.001). PETINIA showed a systemic positive bias with a mean difference of 0.66 mg/L compared to LC-MS. However, the magnitude of the positive bias decreased to 0.44 mg/L within the therapeutic range of MPA. Multiple logistic regression showed that MPA trough level determined by PETINIA was an independent risk factor for adverse events (odds ratio 2.28, 95% CI 1.25–4.16, p = 0.007). MPA trough level predicted adverse events with a sensitivity of 77.8% and a specificity of 86.7% using a cut-off level of 5.25 mg/L. Conclusions Good correlation between the two methods indicates that PETINIA is an acceptable method for the monitoring of MPA therapeutic levels. Furthermore, MPA trough level obtained by PETINIA is a useful monitoring tool to minimize toxicity in KTRs.

1 December 2008 in Annals of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
JPJung Ran Park
Jung Ran Park
MKMi Hye Kim
Mi Hye Kim
JWJungmin Woo
Jungmin Woo
SLSeung Jae Lee
Seung Jae Lee
KSKyung Eun Song
Kyung Eun Song
Saliva is increasingly being used as a specimen for systemic disease as well as for oral health status. Especially, salivary amylase has been studied as an excellent index for psychological stress. Authors evaluated the measurement of salivary amylase activities collected by Salivettes (Sarstedt, Germany). Saliva specimens were collected from 13 healthy adults between 10:00 and 11:00 a.m. Participants were asked to gently chew tampons of Salivettes for 1 min. Immediately after collection, all specimens were stored frozen. On the day of testing, they were centrifuged after thawing and diluted with distilled water. Amylase was measured by Dimension RxL Max (Dade Behring Inc., USA). We evaluated precision, linearity, and recovery rate of Salivette. Amylase activities between collection of saliva by Salivette and passive drool were compared, and also the changes of amylase by the storage temperature were evaluated. Intra-run CVs for three levels of amylase were excellent. Between-day CVs and total CVs were good only for mid and high levels. A good linear relationship was found at all diluted levels. Dosing Salivettes with 2 mL, 1.5 mL, and 1 mL yielded sample recovery 85.5+/-2.4%, 82.4+/-1.5%, and 72.2+/-3.1%, respectively and amylase recovery 78.9+/-10.9%, 74.1+/-13.7%, and 37.3+/-26.9%, respectively. Amylase by Salivette and passive drool were correlated well (r=0.757), although they showed a significant difference. Amylase activity was not affected by the storage temperature. Measurement of salivary amylase using Salivette could be a useful test having good intra-run CVs and linearity. More than 1.5 mL of saliva would be needed to have more than 70% recovery of Salivette.

3 April 2020 in HLA
Verified
Journal Article
Closed access
PDF file
JHJi Yeon Ham
Ji Yeon Ham
SCSo‐Jung Choi
So‐Jung Choi
JRJimin Ryu
Jimin Ryu
NLNan Young Lee
Nan Young Lee
KSKyung Eun Song
Kyung Eun Song

1 January 2015
Verified
Journal Article
Closed access
JHJi Yeon Ham
Ji Yeon Ham
JSJang Soo Suh
Jang Soo Suh
WLWon-Kil Lee
Won-Kil Lee
KSKyung Eun Song
Kyung Eun Song

1 January 2016 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
JHJi Yeon Ham
Ji Yeon Ham
KSKyung Eun Song
Kyung Eun Song
Article Impact of specimen mixing methods on presepsin point-of-care test results using whole blood was published on May 1, 2016 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 54, issue 5).