29 December 2020 in Optics & Laser Technology
5 January 2024 in Applied Thermal Engineering
21 May 2025 in Energy Conversion and Management
13 August 2024 in Arabian Journal for Science and Engineering
An essential factor influencing photovoltaic (PV) panel performance is its operating temperature. Various active and passive cooling methods have been explored in the literature to mitigate the effects of high operating temperatures; however, recent research has shown a growing interest in hybrid cooling systems that combine both active and passive approaches. In this context, phase change material (PCM) serves as a passive cooling method, while fluid is employed as an active cooling medium. This study introduces a channel into the PV panel base through which fluid flows. Additionally, a PCM layer is placed at the bottom of the water channel to reduce the average temperature of the fluid, thus extracting more heat compared to direct contact with the PV panel. The proposed model is compared with traditional water-cooled PV panels using a parametric approach, with varying parameters including concentration ratio, environmental temperature, wind speed, mass flow rate of water in the channel, and inlet temperature. The study findings reveal that the proposed model leads to an increase in electricity production within the range of 1.4–7 kW, an improvement in PV efficiency between 1.6 and 3.8%.
5 August 2022 in International Journal for Numerical Methods in Biomedical Engineering
1 January 2018 in Journal of Enhanced Heat Transfer
Thermal energy storage tanks are widely used in many applications. Therefore, there are many studies in the literature on increasing the efficiency of thermal tanks. Also, air bubble injection systems were used in many types of the heat exchanger in literature but there is no study about the effect of air bubble injection on the thermal storage tank performance. In this study, air bubble injection system was integrated into the tank and effect of the system on heat transfer examined experimentally. Experimental set up was occurred thermal storage tank and coiled tube. Experiments were carried out for the tank with air bubble injection and tank without air bubble injection and compared each other. The results of the study showed that air bubble injection systems increased thermal power transmission at the value of 1.261, overall heat transfer coefficient between the tank and coiled tube the rate of 44,1%. and exergy value in the coiled tube the rate of 21%. But, exergy value in the storage tank decrease the rate of 13 % in the tank with air bubble injection. This means that with the air bubble injection system, the amount of convection in the tank increases and thus the heat transfer increases. So that the use of the air bubble injection system would be beneficial in systems expected to have a high heat transfer rate.