Scott L. Delp

Scott L. Delp

Auto-generated profile, based on publicly available information

Scott L. Delp

Department of Bioengineering, Stanford University, Stanford, CA, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
ARApoorva Rajagopal
Apoorva Rajagopal
CDChristopher L. Dembia
Christopher L. Dembia
MDMatthew S. DeMers
Matthew S. DeMers
DDDenny D. Delp
Denny D. Delp
JHJennifer L. Hicks
Jennifer L. Hicks
SDScott L. Delp
Scott L. Delp
Objective: Musculoskeletal models provide a noninvasive means to study human movement and predict the effects of interventions on gait. Our goal was to create an open-source 3-D musculoskeletal model with high-fidelity representations of the lower limb musculature of healthy young individuals that can be used to generate accurate simulations of gait. Methods: Our model includes bony geometry for the full body, 37 degrees of freedom to define joint kinematics, Hill-type models of 80 muscle-tendon units actuating the lower limbs, and 17 ideal torque actuators driving the upper body. The model's musculotendon parameters are derived from previous anatomical measurements of 21 cadaver specimens and magnetic resonance images of 24 young healthy subjects. We tested the model by evaluating its computational time and accuracy of simulations of healthy walking and running. Results: Generating muscle-driven simulations of normal walking and running took approximately 10 minutes on a typical desktop computer. The differences between our muscle-generated and inverse dynamics joint moments were within 3% (RMSE) of the peak inverse dynamics joint moments in both walking and running, and our simulated muscle activity showed qualitative agreement with salient features from experimental electromyography data. Conclusion: These results suggest that our model is suitable for generating muscle-driven simulations of healthy gait. We encourage other researchers to further validate and apply the model to study other motions of the lower extremity. Significance: The model is implemented in the open-source software platform OpenSim. The model and data used to create and test the simulations are freely available at https://simtk.org/home/full_body/, allowing others to reproduce these results and create their own simulations.

12 August 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
PSPatrick Slade
Patrick Slade
AHAyman Habib
Ayman Habib
JHJennifer L. Hicks
Jennifer L. Hicks
SDScott L. Delp
Scott L. Delp
Objective: Analyzing human motion is essential for diagnosing movement disorders and guiding rehabilitation for conditions like osteoarthritis, stroke, and Parkinson's disease. Optical motion capture systems are the standard for estimating kinematics, but the equipment is expensive and requires a predefined space. While wearable sensor systems can estimate kinematics in any environment, existing systems are generally less accurate than optical motion capture. Many wearable sensor systems require a computer in close proximity and use proprietary software, limiting experimental reproducibility. Methods: Here, we present OpenSenseRT, an open-source and wearable system that estimates upper and lower extremity kinematics in real time by using inertial measurement units and a portable microcontroller. Results: We compared the OpenSenseRT system to optical motion capture and found an average RMSE of 4.4 degrees across 5 lower-limb joint angles during three minutes of walking and an average RMSE of 5.6 degrees across 8 upper extremity joint angles during a Fugl-Meyer task. The open-source software and hardware are scalable, tracking 1 to 14 body segments, with one sensor per segment. A musculoskeletal model and inverse kinematics solver estimate Kinematics in real-time. The computation frequency depends on the number of tracked segments, but is sufficient for real-time measurement for many tasks of interest; for example, the system can track 7 segments at 30 Hz in real-time. The system uses off-the-shelf parts costing approximately $100 USD plus $20 for each tracked segment. Significance: The OpenSenseRT system is validated against optical motion capture, low-cost, and simple to replicate, enabling movement analysis in clinics, homes, and free-living settings

17 January 2025 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
AFAntoine Falisse
Antoine Falisse
SUScott D. Uhlrich
Scott D. Uhlrich
ACAkshay Chaudhari
Akshay Chaudhari
JHJennifer L. Hicks
Jennifer L. Hicks
SDScott L. Delp
Scott L. Delp
Objective: Human pose estimation models can measure movement from videos at a large scale and low cost; however, open-source pose estimation models typically detect only sparse keypoints, which leads to inaccurate joint kinematics. OpenCap, a freely available service for researchers to measure movement from videos, mitigates this issue using a deep learning model—the marker enhancer—that transforms sparse video keypoints into dense anatomical markers. However, OpenCap performs poorly on movements not included in the training data. Here, we create a much larger and more diverse training dataset and develop a more accurate and generalizable marker enhancer. Methods: We compiled marker-based motion capture data from 1176 subjects and synthesized 1433 hours of video keypoints and anatomical markers to train the marker enhancer. We evaluated its accuracy in computing kinematics using both benchmark movement videos and synthetic data representing unseen, diverse movements. Results: The marker enhancer improved kinematic accuracy on benchmark movements (mean error: 4.1$^\circ$, max: 8.7$^\circ$) compared to using video keypoints (mean: 9.6$^\circ$, max: 43.1$^\circ$) and OpenCap's original enhancer (mean: 5.3$^\circ$, max: 11.5$^\circ$). It also better generalized to unseen, diverse movements (mean: 4.1$^\circ$, max: 6.7$^\circ$) than OpenCap's original enhancer (mean: 40.4$^\circ$, max: 252.0$^\circ$). Conclusion: Our marker enhancer demonstrates both improved accuracy and generalizability across diverse movements. Significance: We integrated the marker enhancer into OpenCap, thereby offering its thousands of users more accurate measurements across a broader range of movements.

27 March 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
MRMichael Raitor
Michael Raitor
SRSandra Waugh Ruggles
Sandra Waugh Ruggles
SDScott L. Delp
Scott L. Delp
CLC. Karen Liu
C. Karen Liu
SCSteven H. Collins
Steven H. Collins
Exoskeletons are a burgeoning technology with many possible applications to improve human life; focusing the effort of exoskeleton research and development on the most important features is essential for facilitating adoption and maximizing positive societal impact. To identify important focus areas for exoskeleton research and development, we conducted a survey with 154 potential users (older adults) and another survey with 152 clinicians. The surveys were conducted online and to ensure a consistent concept of an exoskeleton across respondents, an image of a hip exoskeleton was shown during exoskeleton-related prompts. The survey responses indicate that both older adults and clinicians are open to using exoskeletons, fall prevention and joint pain reduction are especially important features, and users are likely to wear an exoskeleton in the scenarios when it has the greatest opportunity to help prevent a fall. These findings can help inform future exoskeleton research and guide the development of devices that are accepted, used, and provide meaningful benefit to users.

25 October 2024 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
AGAnthony A. Gatti
Anthony A. Gatti
LBLouis Blankemeier
Louis Blankemeier
DVDave Van Veen
Dave Van Veen
BHBrian Hargreaves
Brian Hargreaves
SDScott L. Delp
Scott L. Delp
ACAkshay Chaudhari
Akshay Chaudhari
Analyzing anatomic shapes of tissues and organs is pivotal for accurate disease diagnostics and clinical decision-making. One prominent disease that depends on anatomic shape analysis is osteoarthritis, which affects 30 million Americans. To advance osteoarthritis diagnostics and prognostics, we introduce ShapeMed-Knee, a 3D shape dataset with 9,376 high-resolution, medical-imaging-based 3D shapes of both femur bone and cartilage. Besides data, ShapeMed-Knee includes two benchmarks for assessing reconstruction accuracy and five clinical prediction tasks that assess the utility of learned shape representations. Leveraging ShapeMed-Knee, we develop and evaluate a novel hybrid explicit-implicit neural shape model which achieves up to 40% better reconstruction accuracy than a statistical shape model and two implicit neural shape models. Our hybrid models achieve state-of-the-art performance for preserving cartilage biomarkers (root mean squared error ≤ 0.05 vs. ≤ 0.07, 0.10, and 0.14). Our models are also the first to successfully predict localized structural features of osteoarthritis, outperforming shape models and convolutional neural networks applied to raw magnetic resonance images and segmentations (e.g., osteophyte size and localization 63% accuracy vs. 49-61%). The ShapeMed-Knee dataset provides medical evaluations to reconstruct multiple anatomic surfaces and embed meaningful disease-specific information. ShapeMed-Knee reduces barriers to applying 3D modeling in medicine, and our benchmarks highlight that advancements in 3D modeling can enhance the diagnosis and risk stratification for complex diseases. The dataset, code, and benchmarks are freely accessible.

7 August 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
JSJon P. Stingel
Jon P. Stingel
JHJennifer L. Hicks
Jennifer L. Hicks
SUScott D. Uhlrich
Scott D. Uhlrich
SDScott L. Delp
Scott L. Delp
Connecting the legs with a spring attached to the shoelaces, called an exotendon, can reduce the energetic cost of running, but how the exotendon reduces the energetic burden of individual muscles remains unknown. We generated muscle-driven simulations of seven individuals running with and without the exotendon to discern whether savings occurred during the stance phase or the swing phase, and to identify which muscles contributed to energy savings. We computed differences in muscle-level energy consumption, muscle activations, and changes in muscle-fiber velocity and force between running with and without the exotendon. The seven of nine participants who reduced energy cost when running with the exotendon reduced their measured energy expenditure rate by 0.9 W/kg (8.3%). Simulations predicted a 1.4 W/kg (12.0%) reduction in the average rate of energy expenditure and correctly identified that the exotendon reduced rates of energy expenditure for all seven individuals. Simulations showed most of the savings occurred during stance (1.5 W/kg), though the rate of energy expenditure was also reduced during swing (0.3 W/kg). The energetic savings were distributed across the quadriceps, hip flexor, hip abductor, hamstring, hip adductor, and hip extensor muscle groups, whereas no changes were observed in the plantarflexor or dorsiflexor muscles. Energetic savings were facilitated by reductions in the rate of mechanical work performed by muscles and their estimated rate of heat production. By modeling muscle-level energetics, this simulation framework accurately captured measured changes in whole-body energetics when using an assistive device. This is a useful first step towards using simulation to accelerate device design by predicting how humans will interact with assistive devices that have yet to be built.