Bahar Di̇ken

Bahar Di̇ken

Auto-generated profile, based on publicly available information

Bahar Di̇ken

TÜBITAK

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2021 in Tekirdağ Ziraat Fakültesi Dergisi
Verified
Journal Article
Closed access
PDF file
AAAylin DUMAN ALTAN
Aylin DUMAN ALTAN
BDBahar Di̇kEn
Bahar Di̇kEn
BKBİROL KAYISOGLU
BİROL KAYISOGLU
Solar energy is one of the renewable energy sources that has been in high demand in the last decades. With the increasing penetration of photovoltaic (PV) systems in around the world, accurate estimation of the power output of PV systems has become an important issue. Since PV systems directly convert sunlight into electrical energy, PV power output varies depending on environmental conditions. In order to deal with the periodic and non-stationary problems of PV output power, modelling methods are widely use for forecasting. The main purpose of this study is to lead an assessment of forecasting of the PV power outputs in short-time. For this purpose, data are obtained from experimental activities carried out on a real 250 kWp PV stystem, which is located in T.C Tekirdağ Namık Kemal University, Süleymanpaşa district of Tekirdağ province. All parametres are measured hourly with three times according to inclination of the panel setups (0˚, 30˚,60˚). In this sense, this study differs from the previously studies in literature, as it expands the forecasting model with considering of different panel angle. In the first stage, the significant variables for predicting PV power output are identified based on both correlation analysis and stepwise regression analysis. The findings are shown that solar radiation and angle of inclination of the panel are significant predictors of the generation of PV power. In the second stage, three different model are proposed based on Time Series Analysis (TSA) and Artificial Neural Network (ANN) approaches in order to predict power production of PV system. Furthermore, the accuracies of the models are analyzed in order to better understand the intrinsic errors caused and to evaluate its potential in energy forecasting applications. All models are compared in terms of the correlation coefficient (R), coefficient of determination (R2), mean absolute percentage error (MAPE). The results of analyses show that the ANN models have higher accuracy than the TSA model for forecasting PV power.

1 September 2022 in Tekirdağ Ziraat Fakültesi Dergisi
Verified
Journal Article
Closed access
PDF file
BDBahar Di̇ken
Bahar Di̇ken
BKBİROL KAYISOGLU
BİROL KAYISOGLU
As a result of the rapid decrease in fossil fuels and increasing energy demand, countries have turned to alternative energy sources. Renewable resources, which are alternative to fossil resources and are environmentally friendly, are clean and inexhaustible energy resources. Solar energy is one of these alternative energy sources This study; With the RetScreen program, it is aimed to analyze the suitability of the system and observe its performance before the PV system is installed. Features affecting the performance of PV systems; It has been designed by considering factors such as the position of the panel, the angle of inclination, shading and panel type. Shadow analysis was performed with the Helioscope program. In the shadow analysis, firstly, the geographical location is defined and the determined parameters are entered into the system. Technical, energy and economic analysis of the 14 kW solar system for the Ziraatbiyotek building was made. The analysis was made in 2 different scenarios and the positive and negative aspects of the solar system to be installed in the building were revealed. The Ziraatbiyotek building, where the study was carried out, was established in the Naip District of the Suleymanpasa district of Tekirdag province. For the Ziraatbiyotek laboratory building, 60 panels of the GES power plant with an area of 405 m(2) were used. The brand of the selected panel is Astronergy Solar and each has a power capacity of 240 W. The panel inclination is 30 degrees and the azimuth angle is 0 degrees in the RetScreen program. Polycrystalline was used as the panel type in two different scenarios. In the first scenario, emission reduction support was not included and the payback period of the system was 10.4 years, and in the other, $15 tCO(2)(-1) and annual support of $142 were included and the payback period of the system was 9.8 years. According to the results obtained with the program, 20.1 Wh energy produced by the solar panel system decreased 9.5 tCO(2) greenhouse gas emissions. It has been obtained that if a 14 kW solar energy system is installed in the Ziraatbiyotek building, approximately 40% of the annual electricity need will be met from solar energy.

31 January 2020 in El-Cezeri Fen ve Mühendislik Dergisi
Verified
Journal Article
Open access
PDF file
BDBahar Di̇ken
Bahar Di̇ken
TATürkan Aktaş
Türkan Aktaş
BKBirol Kayi̇şoğlu
Birol Kayi̇şoğlu
MEMerve Eremkere
Merve Eremkere
GDGülizar Demi̇rtaş
Gülizar Demi̇rtaş
En tr Drying process is one of the methods used to supply consuming of fruits and vegetables out of the harvesting period and to preserve the market value. In this research, kiwi fruit, which is rapidly growing of its production in our country in recent years, was sliced in 3 mm thickness and dried at different temperatures (50-60-70 °C) and constant airspeed (2.2 m s-1) in a hot air dryer as thin layer. The sorption isotherms, which are very important in terms of continuity of product quality stability and which are used to understand the physicochemical relationship between water and product, were determined at 3 different temperatures (30, 40 and 50 °C) and 5 different ambient relative humidity conditions for fresh and dried kiwi samples. The obtained experimental sorption data were adapted to 4 different models, namely BET, GAB, Oswin and Smith models. Four mathematical drying models namely Henderson and Pabis, Page, Logarithmic, Wangh and Singh were applied to the experimental results of drying processes. It was determined that the most suitable mathematical model is Page model in hot air drying of kiwi according to the comparison of root mean square error (RMSE), chi-square (χ2) and model efficiency (EF) values obtained by modeling of drying data. It was determined that the most suitable mathematical model is GAB model for the sorption behavior of kiwi fruit. The effective diffusion coefficient values ranged from 2.73936 x 10-10 (50 ˚C) to 3.89772 x 10-10 m2 s-1 (70 ˚C) depending on the temperature. Meyve ve sebzelerin hasat dönemi dışında da tüketilmesi ve pazar değerinin korunması amacıyla kullanılan yöntemlerin başında kurutma işlemi gelmektedir. Bu çalışmada, son yıllarda ülkemizde üretimi hızla artan kivi meyvesi, 3 mm kalınlıkta dilimlenerek, sıcak havalı bir kurutucuda farklı sıcaklıklarda (50-60-70˚C) ve sabit hava hızında (2.2 m/s) ince tabaka halinde kurutularak kurutma karakteristikleri saptanmıştır. Su ve ürün arasındaki fizikokimyasal ilişkiyi anlamak ve ürünün kalite stabilitesinin devamlılığı bakımından oldukça önemli olan sorpsiyon izotermleri de (desorpsiyon ve adsorpsiyon) 30, 40 ve 50 ˚C olmak üzere 3 farklı sıcaklık ve 5 farklı ortam bağıl nemi koşulunda yaş ve kurutulmuş örnekler kullanılarak belirlenmiştir. Elde edilmiş olan deneysel sorpsiyon verileri 4 farklı modele yani BET, GAB, Oswin ve Smith modellerine uydurulmuştur. Kurutma işlemlerine ilişkin deneysel sonuçlara ise Henderson ve Pabis, Page, Logaritmik, Wangh ve Singh olmak üzere 4 matematiksel kurutma modeli uygulanmıştır. Kurutma verilerinin modellenmesi sonucu elde edilmiş olan ortalama karesel hata (RMSE), khi-kare (χ2) ve model etkinliği (EF) değerlerinin karşılaştırılması ile kivinin sıcak hava ile kurutulmasında en uygun matematiksel modelin Page modeli olduğu, sorpsiyon davranışları için en uygun modelin ise GAB modeli olduğu tespit edilmiştir. Efektif difüzyon katsayısı sıcaklığa bağlı olarak 2.73936 x 10-10 (50 ˚C) ile 3.89772 x 10-10 m2/s (70˚C) arasında değişmiştir.